Development of the Aspherical Lens Polishing System with MR Fluid and Analysis of the Basic Polishing Characteristic of MR Polishing System (MR Fluid를 이용한 비구면 렌즈 연마 시스템 개발 및 기초 연마 특성 분석)

  • Lee, Jung-Won;Cho, Myeong-Woo;Ha, Seok-Jae;Hong, Kwang-Pyo;Cho, Yong-Kyu;Kim, Byung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.92-99
    • /
    • 2014
  • An aspherical lens, which resolves several problems with a spherical lens,typically serves asa key part of an optical system. Generally, an aspherical lens is fabricated using a diamond turning machine or by mean of injection molding. However, residual stress and/or tool marks can arise when using a commercial fabricating method such as DTM or injection molding. A polishing process, thus, is commonly used to obtain a high-precision aspherical lens. In this study, a polishing method using MR fluid was applied to minimize several problems, in this case residual stress and the creation of tool marks, during the cutting process. The MR polishing system was developed to polish aspherical lenses. A series of experiments were performed to obtain a very fine surface roughness. PMMA (the lens material for molding) was used as a workpiece, and the gap size, magnetic field intensity, wheel speed and feed rate were selected as the parameters in this study. Finally, a very fine surface roughness of Ra=2.12nm was obtained after MR polishing.

Design and Fabrication of Micro Laser Module for Heat Assisted Magnetic Recording (차세대 열 보조 자지기록용 마이크로 레이저 모듈 설계 및 제작)

  • Lee, S.C.;Choi, Y.B.;Kim, Y.J.;Kim, D.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.68-69
    • /
    • 2009
  • Heat Assisted Magnetic Recording (HAMR) is one of the most promising candidates for high density magnetic storages over 1 Tb/$in^2$ areal density. Since the precise light delivery to the head is a key factor to realize HAMR application, it is required to establish the light delivery using micro laser module and micro actuator. For the careful control of micro actuator, a laser module was designed including laser diode, optical fiber, collimating lens, and fabricated V-groove substrate. In addition, the basic aligning method between the laser module and HAMR head was studied by the detection of current change in photo diode due to the amount of reflected light from the head.

  • PDF

Electron Beam Simulation Technology for CRTs

  • Shirai, Shoji;Oku, Kentarou
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.385-387
    • /
    • 2002
  • The electron beam simulation technology is indispensable for the recent electron gun design. The technology is becoming more and more important for deflection yoke (DY) design and investigation of the interference effects between gun and DY. Further, it may become vital even for shadow mask, glass funnel, exposure lens and magnetic shield.

  • PDF

Surface Dose Measurement of Electron Beam within the Magnetic Field Variation (자기장 내에서 전자선의 표면선량 변화 측정)

  • Je, Jae-Yong;Noh, Kyung-Suk;Shin, Oon-Jae;Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This paper describes a electron field presence of magnetic field, intensity and shape surface dose variation to clinical application possibility. Materials and Methods: The using 6 MeV electron and $10{\times}10\;cm^2$ field size, 9 hole to shielding block make the by measure the film, when the magnetic field position inside and outside of the X-Omat film and parallel plate ionization chamber using the surface dose measured. Results: Present of 4 cm to the side at angle about 3 degree from beam center, use of ring type magnetic is 0.9% increase the surface dose, lens block located in the magnetic field the surface dose 1.58% increase, half magnetic field's position on the side of them at the field center of the 3.6% increase of the surface dose. Conclusion: Surface dose variation is with magnetic field about the mean electron beam of progress direction change, orbit region patient's is inconvenient without surface dose increase percentage case goodness will be used as a useful way.

  • PDF

Machining Properties to Nano-Level Mirror Surface Finishing for Fine Grained WC-Co 18% Alloy using Magnetic Polishing Slurry (자성연마슬러리를 이용한 초미립 초경합금(WC-Co 18%)의 나노급 경면가공 특성)

  • Kwak, Tae-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.1
    • /
    • pp.102-107
    • /
    • 2009
  • This study has been focused on an effective surface finishing method combining ELID (ELectrolytic In-process Dressing) and MAP (Magnetic Assisted Polishing) for the nano-precision mirror grinding of glass-lens molding mould. ELID grinding is an excellent technique for mirror grinding of various advanced metallic or nonmetallic materials. A polishing process is also required for elimination of scratches present on ELID grinded surfaces. MAP has been used as polishing method due to its high polishing efficiency and superior surface quality. It also presents some techniques for achieving the nanometer roughness of the hard material such as WC-Co, which are extensively used in precision tooling material.

Control of Object Transport Direction Using Vibration of Flexural Beam in Ultrasonic Transport System (초음파 이송장치에서 탄성 빔의 진동을 이용한 물체 이송방향 제어)

  • Jeong, Sang-Hwa;Park, Jin-Wan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1241-1246
    • /
    • 2007
  • In recent years, the semiconductor industry and the optical industry are developed rapidly. The recent demands have expanded for optical components such as the optical lens, the optical semiconductor and the measuring instrument. Object transport systems are driven typically by the magnetic field and the conveyer belt. Recent industry requires more faster and efficient transport system. However, conventional transport systems are not adequate for transportation of optical elements and semiconductors. The conveyor belts can damage precision optical elements by the contact force and magnetic systems can destroy the inner structure of semiconductor by the magnetic field. In this paper, the levitation transport system using ultrasonic wave is developed for transporting precision elements without damages. The steady state flexural vibration of the beam is expressed using Euler-Bernoulli beam theory. The transport direction of an object is examined according to phase difference and frequency. The theoretical results are verified by experiments.

  • PDF

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동 액추에어터)

  • Cheong, Young-Min;Lee, Jin-Won;Kim, Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1000-1003
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. This newly suggested actuator features DVD-RAM recording, we achieved the high focus & track AC sensitivity and the greatly stabilized system.

  • PDF

A Magnetorheological Polishing System (자기유변유체를 이용한 연마가공 시스템)

  • 김영민;신영재;이응숙;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.324-328
    • /
    • 2003
  • The Magnetoeheological fluid has the properties that it's viscosity has dramastic changed under some magnetic fields therefore, Magnetorhlogical fluids has been used for micro polishing of the micro part( for example, a aspherical surface in a micro lens). The polishing process may appears as follows. A part rotating on the spindle is brought into contact with an Magnetorhological finshing(MRF) fluids which is set in motion by the moving wall. In the region where the part and the MRF fulid ate brought into contact, the applied magnetic field creates the conditions necessary for the material removal from the part surface. The material removal takes place in a certain region contacting the surface of the part which can be called the polishing spot or zone. The polishing mechanism of the material removal in the contact zone is considered as a process governed by the particularities of the Bingham flow in the contact zone. Resonable calculated and experimental magnitudes of the material removal rate f3r glass polishing lends support the validity of the approach.

  • PDF

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동액추에이터)

  • Cheong Young Min;Lee Jin Won;Kim Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.397.1-397
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. (omitted)

  • PDF

The Development of Polishing System a Magnetorheological Fluids (자기유변유체를 이용한 연마가공 시스템의 개발)

  • 신영재;김동우;이응숙;김경웅
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.46-52
    • /
    • 2004
  • The Magnetorheological fluid has the properties that its viscosity has drastic changed under some magnetic fields therefore, Magnetorheological fluids has been used fur micro polishing of the micro part(for example, a spherical surface in a micro lens). The polishing process may appears as follows. A part rotating on the spindle is brought into contact with an Magnetorheological finishing(MRF) fluids which is set in motion by the moving wall. In the region where the part and the MRF fluid are brought into contact, the applied magnetic field creates the conditions necessary for the material removal from the part surface. The material removal takes place in a certain region contacting the surface of the part which can be called the polishing spot or zone. The polishing mechanism of the material removal in the contact zone is considered as a process governed by the particularities of the Bingham flow in the contact zone. Resonable calculated and experimental magnitudes of the material removal rate for glass polishing lends support the validity of the approach.