• Title/Summary/Keyword: Magnetic force improvement

검색결과 70건 처리시간 0.03초

솔레노이드 밸브의 흡인력 개선을 위한 연구 (A Study on the Improvement of Attraction Force of Solenoid Operated Valves)

  • 임병주;박창대;이태구;윤소남;정경열
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.121-122
    • /
    • 2012
  • In this research, we studied on improvement of the attraction force of solenoid operated valve for normal operation in harsh environment like vessel. Attraction force of the solenoid valves is effected by the B-H characteristics of magnetic material and the size of coil. In order to specify impact of the affection, we performed the B-H characteristics test and attraction force. Test results show that magnetic flux densities of the materials are difference each other more than 2 times in same magnetic intensity, and attraction force of the solenoid valve is 1.7 times difference as changes of resistance and the number of coil winding of solenoid.

  • PDF

알루미늄의 자기연마가공에서 영구자석을 이용한 자기력향상 (Improvement of Magnetic Force and Experimental Verification for Magnetic Abrasive Polishing of Aluminum Alloy)

  • 김상오;곽재섭
    • 한국공작기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.23-29
    • /
    • 2008
  • Magnetic abrasive polishing is one of the nontraditional machining technologies newly developed. But it was very difficult to cut non-magnetic materials using MAP process because the process was fundamentally possible by help of a magnetic farce. In this study, we aimed to verify analytically formation of the magnetic field in a case of the nonmagnetic materials especially focused on an aluminum alloy. And also an improving strategy of the magnetic force for the non-magnetic materials was proposed and experimentally verified. Design of experimental method was adopt for assessment of parameters' effect on the MAP results of the aluminum alloy.

Optimal Shape Design of Magnetic Actuators for Magnetic and Dynamic Characteristic Improvement

  • Yoo, Jeong-Hoon;Jung, Jae-Yeob;Hong, Hyeok-Soo
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.268-270
    • /
    • 2011
  • This study introduces a new topology optimization scheme combing the genetic algorithm (GA) with the on/off sensitivity method for the magnetic actuator core and the armature design. The design process intended to maximize the first eigen-frequency of the armature part and the magnetic actuating force acting on the armature simultaneously. GA based optimal design was carried out to obtain the initial structure and the modified on/off sensitivity method was succeeded to accelerate the design process. Final results show tens of percent improvement in actuating force as well as the first eigen-frequency of the armature.

최적화 기법을 사용한 초소형 카메라 조리개 셔터장치의 성능향상 (The Improvement of Performance in an Ultra small Camera Iris-Shutter Device using Topology Optimization)

  • 박순옥;유정훈
    • 정보저장시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.53-57
    • /
    • 2009
  • This study is concerned with the design of a camera iris-shutter device for producing force. The camera iris-shutter with yoke should have a smaller size and a bigger magnetic force than the previous model. Since the induced magnetic force operates shutter movement, the magnetic force maximization for a given input current is an important issue. To achieve the goal, new system is designed by the topology optimization method. The design is refined through the design of experiments to find the detail camera iris shutter design satisfying design constraints.

  • PDF

A study on the changes in attractive force of magnetic attachments for overdenture

  • Leem, Han-Wool;Cho, In-Ho;Lee, Jong-Hyuk;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2016
  • PURPOSE. Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS. Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS. Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION. Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

2상 8극 HB형 LPM의 마이크로스텝 구동에 의한 추력특성 개선 (Improvement of Thrust Force Characteristics by Micro-step Drive of 2 Phase 8 Pole HB type LPM)

  • 김성헌;이은웅;김일중;조현길;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.140-142
    • /
    • 1997
  • After finding the harmonic components by measuring the thrust force, which affects high accuracy position control during micro-step drive of LPM, the exciting current was calculated to remove them. Also the detent force being induced by magnetic flux density of permanent magnetic was measured. It was comfirmed that the tooth and slot width was designed properly thresh the analysis of detent force.

  • PDF

Considerations on Improvement of Moving Properties for Magnetic Actuator Capable of Movement in Pipe

  • Izumikawa, Tomohiro;Yaguchi, Hiroyuki
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.263-267
    • /
    • 2011
  • The present paper proposes a novel cableless magnetic actuator with a new propulsion module that exhibits a very high thrusting force. This actuator contains an electrical inverter that directly transforms DC from button batteries into AC. The electrical DC-AC inverter incorporates a mass-spring system, a reed switch, and a curved permanent magnet that switches under an electromagnetic force. The actuator is moved by the inertial force of the mass-spring system due to mechanical resonance energy. The experimental results show that the actuator is able to move upward at a speed of 33 mm/s when using 10 button batteries when pulling a 10 g load mass. This cableless magnetic actuator has several possible applications, including narrow-pipe inspection and maintenance.

자기연마기술을 이용한 고속절삭공구의 성능향상에 관한 연구 (A Study on the Improvement of Performance for High Speed Cutting Tool using Magnetic Fluid Polishing Technique)

  • 조종래;양순철;정윤교
    • 한국공작기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.32-38
    • /
    • 2006
  • The magnetic fluid polishing technique can polish the tool of complex shape, because the polishing method which polishes as compress the workpiece by the magnetism abrasives to arrange to the linear according to the line of magnetic force. Therefore, we producted the magnetic fluid polishing device in order that mirror like finishing processes the tool surface. In order to a polishing condition selection, polishing characteristic was estimated by polishing conditions which are magnetic flux density, polishing speed, grain size, magnetic fluid. The tool was polished to the selected polishing condition. The result to evaluate the polished tool's performance with the cutting force and tool wear, the polished tool's performance was improved compared with the tool not to polish.

마그네슘 합금강의 제2세대 자기연마에서 표면거칠기 예측모델 개발 (Development of Prediction Model and Parameter Optimization for Second-Generation Magnetic Abrasive Polishing of Magnesium Alloy)

  • 김상오;이성호;곽재섭
    • 대한기계학회논문집A
    • /
    • 제35권4호
    • /
    • pp.401-407
    • /
    • 2011
  • 본 연구에서는 AZ31B 마그네슘 합금 평판 연마에 제 2세대 자기연마공정을 적용하고 실험계획법을 통해 공정인자들의 특성을 평가하였으며, 2차 반응표면모델을 이용한 표면거칠기 예측모델을 개발하였다. 비자성체 재료의 기존 자기연마 공정에서는 재료의 표면에서 자기력이 낮아 표면거칠기의 향상에 효율이 낮은 단점을 가진다. 이를 보완하기 위하여 전자석 배열을 이용한 자기력 테이블을 자기연마 공정에 적용하여 비자성체 표면의 자기력을 향상시킬 수 있었다. 이러한 시스템을 제 2세대 자기연마라 일컫고, 실험계획법에 따른 공정 인자 평가 결과, 자기력 테이블의 전자석 세기가 AZ31B 평판의 표면 거칠기 향상에 가장 큰 영향을 가지고 있음을 확인했다. 또한 자기력 테이블과 공구의 회전속도에 따른 반응표면모델을 개발함으로써 마그네슘 자기연마 공정의 효율성을 높일 수 있었다.