• Title/Summary/Keyword: Magnetic field sensor

Search Result 488, Processing Time 0.025 seconds

Development of Methodology to Measure the Thickness of Pipes using Magnetic Field (마그네틱 필드를 이용한 배관 두께 측정 방법론 개발)

  • Kim, Mi Na;Chai, Jang Bom;Park, Il Han;Kim, E Noch
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.47-53
    • /
    • 2010
  • In this research project, development of methodology to measure the thickness of pipes in the wide range using magnetic field. The magnetic field spreading in the sensor and the plate was modeled in the cases of the various thicknesses in plate. Based on the analysis, sensors were designed, manufactured and tested to optimize the specifications of the sensor. The sensor can be used in high temperature through calibration. And the uncertainty of the sensor was estimated.

  • PDF

An implementation of a magnetic-field measurement system based on optical sensor (광센서를 이용한 자기장 계측 장치 구현)

  • Kim, Young-Soo;Park, Byung-Seok;Kim, Myong-Soo;Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.219-222
    • /
    • 2002
  • In this paper, some parameters are studied for the performance improvement of a bulk optical magnetic-field sensor. The performance of optical magnetic-field sensor is influenced by optical intensity change and wavelength change of light source, and phase shift so called optical bias mismatch. A magnetic field measuring system based on optical Faraday sensor is implemented and tested in the current range from 10 ampere to 200 ampere. The test result shows implemented system has goof linearity.

  • PDF

Fabrication and Properties of MI Sensor Device using CoZrNb Films (CoZrNb막을 이용한 MI센서 소자의 제작 및 특성)

  • Hur, J.;Kim, Y.H.;Shin, K.H.;Sa-Gong, G.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • Magneto-Impedance(MI) sensor is a highly sensitive sensor, which was able to detect a weak geomagnetic field. It also has a merit to be able to build in the low power system. In this study, their magnetic permeability and anisotropy field(H$\sub$k/) as a function of some different thickness of sputtered amorphous CoZrNb films with zero-magnetostriction and soft magnetic property are investigated. In order to make a uniaxial anisotropy, film was subjected to the post annealing in a static magnetic field with 1KOe intensity at 250, 300, and 320$^{\circ}C$ respectively for 2 hours. Magnetic properties of films are measured by using a M-H loop tracer. Magnetic permeability of a film is measured over the frequency range from 1 ㎒ to 750㎒. By thickening a CoZrNb film relatively, magnetic permeability and impedance are examine to design the. MI sensor which drives at 50㎒, and thereof fabricated the MI sensor which drives at the 50㎒.

A Study on InSb Magnetic Sensor using Hall Effect (Hall효과를 이용한 InSb가 자기 Sensor에 관한 연구)

  • Jeon, Chun-Saeng
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.113-116
    • /
    • 1994
  • InSb thin film magnetic sensor, which have been prepared on glass substrate by vacuum evaporation, is investigated in this paper. The dependance of Hall voltage on magnetic field and temperature is examined by Hall effect. The variation of Hall voltage with magnetic field is almost linear at constant current drive but it is deviated from the linearity at constant voltage drive. Hall voltage decreases as the ambient temperature increases, so it is necessary to take into account the temperature effect when the InSb thin film is used as magnetic sensor.

  • PDF

Metallic Crack Detections by Planar Inductive Coil Sensor Under AC and DC Magnetic Fields

  • Lee, Joon-Sik;Nam, Baek-Il;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.210-213
    • /
    • 2012
  • To detect the surface and the opposite side cracks on iron specimen under AC and DC magnetic fields, the planar inductive coil sensors were employed. When the induced signals were measured, the planar inductive coil sensor and the magnetic field source were lifted off about 2 mm from the top surface of the specimen. AC magnetic fields and DC magnetic fields were applied to the specimens by single straight Cu coil and NdFeB permanent magnet, respectively. The detected signals at crack positions were good coincidence with those of the simulation results.

Development of Magnetic Field Mapping System Using Robot (로봇을 이용한 자기장 측정 시스템 개발)

  • Kim, Man-Gil;An, In-Seok;Lee, Pyeong-Gi;Park, Sang-Bae;Lee, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.1018-1021
    • /
    • 2003
  • This dissertation is reference to measure visual information about the configuration of magnetic field automatically and materialize the new magnetic field mapping system for the rapid and clear measure by using of the mediocrity orthogonal robot in the three- dimensional space required the measure of magnetic field concurrently. The measuring sensor is composed to be available for the measure of three-dimensional direction of magnetic field by vertically conjoining each of three hall sensors utilized of the hall effect and installed Gaussmeter, which is devised to receive the sensor result and the robot controller, away from the measuring robot in order to minimize the affection of magnetic field. Also, the controller and Gaussmeter are composed of Use interface, RS-232C and IEEE-488.2 communication. Interface system is written in NI's LabVIEW and composed to be able to set up a measuring area, the measuring number of times, two and three-dimensional graph, the velocity of robot and the magnetic field distribution graph of each element by inputting parameters. The materialized magnetic field mapping system expert the collection of the data easily and the effect of utilizing data.

  • PDF

Non-contact critical current measurement using hall probe (Hall probe를 이용한 비접촉 임계전류 측정)

  • Kim, Ho-Sup;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Kim, Tae-Hyung;Ko, Rock-Kil;Ha, Hong-Soo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.7-8
    • /
    • 2009
  • Non-contact critical current measurement apparatus was developed using hall probe which measures the magnetic field distribution across the width of superconducting tape. The hall probe consists of 7 independent hall sensors which lie in a line 600 ${\mu}m$. The difference between maximum and minimum magnetic field in the magnetic filed distribution is a main parameter to determine the critical current. As preliminary research, we calculated the magnetic field intensity at the middle sensor, which is a minimum magnetic field and generated by the circular shielding current modeled by Bean model. We confirmed that there are some parameters that affect on the minimum magnetic field; the distance between superconducting layer and hall sensor, the width of superconducting tape, and the critical current distribution across the width of superconducting tape. Among these parameters, the distance between superconducting layer and hall sensor highly influences on the minimum magnetic field.

  • PDF

The Design and Performance Verification of Collocated Capacitance Sensor for Magnetic Bearing (자기베어링과 공위한 축전센서의 설계 및 성능 평가)

  • 유선중;신동원;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.317-322
    • /
    • 1994
  • The design and performance verification of collocated capacitance sensor system for magnetic bearing is presented. Noncollocation between actuators and sensors may cause unstable rotor behavior. The capacitance sensor is not affected by magnetic field. PCB type capacitance sensor is installed between magnetic bearing polse. so, collocation of sensors and actuators can be achieved. Experiment of sensor's static and dynamic charactistics is conducted. Modeling of the rotor system supported by magnetic bearing is made. And performance comparison between simulation and experiment is showed.

  • PDF

Developing Wearable Joystick Device Using Magnetic Sensor (자기장 센서를 이용한 웨어러블 조이스틱 장치의 개발)

  • Yeo, Hee-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.18-23
    • /
    • 2021
  • There has been demand for many magnetic sensor applications, and to develop low-cost devices, it is critical to accurately understand the behavior of the magnetic field and the characteristics of magnetic sensors and target devices during initial development phase. The magnetic field has been known to have very complicated nonlinear data to calculate, so it has required expensive computing machines or research to accurately calculate the magnetic sensor values. However, this paper introduces a characteristic of a magnetic sensor called the giant magnetoresistance (GMR) and proposes simple and sufficient approaches to develop a wearable joystick device using a magnetic sensor. Particularly, this paper introduces the design factors for how to properly develop a low-cost wearable joystick device using magnetic sensors after carefully considering the mechanism of a real joystick and the characteristics of magnetic sensors. As a result, user test results are provided to show how users can operate this new wearable joystick device.

Magnetic Properties of BiPbSrCaCuO System (Bi계 초전도체의 자기적 효과)

  • 이상헌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.355-357
    • /
    • 2002
  • The relationship between magnetic properties of BiPbSrCaCuO superconductor and externally applied magnetic field was studied to develop a magnetic field polarity sensor. The behavior was related to the magnetic flux trapped in the superconductor, which penetrates through the material by the external magnetic field. Some portion of the superconductor was changed to a normal state by the trapped magnetic flux. Electrical characteristics of the superconductor with trapped magnetic flux were extremely sensitive to the external magnetic field and showed different responses depending on the direction of the magnetic field.

  • PDF