• 제목/요약/키워드: Magnetic field noise

검색결과 329건 처리시간 0.027초

비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발 (Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment)

  • 김인선;김진목;박용기
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

자기장과 CIP 성분비 변화에 따른 MRE의 전단탄성계수에 대한 실험적 조사 (Experimental Investigation for Shear Modulus of MRE due to Magnetic Field and Volume Percent of CIP)

  • 윤지현;파와지;윤규서;정경호;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.753-753
    • /
    • 2008
  • Magneto-rheological elastomers(MRE) are similar to magnetorheological fluids. Thus, rheological properties of MRE can be also controlled by an applied magnetic field. The MRE in this experiment is a mixture of natural rubber(NR), carbonyl iron powder(CIP), ZnO, and sulfur. Three specimens were prepared and tested by using the vibration testing instruments. The magnetic field was generated by the electromagnets. Natural frequencies of the oscillator were changed by the applied magnetic field. The properties of the MRE were increased due to magnetic field strength.

  • PDF

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

High $T_c$ SQUID system for biological immunoassays

  • Enpuku, K.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.7-7
    • /
    • 2000
  • A high $T_c$ SQUID system is developed for the application to biological immunoassay. In this application, magnetic nanoparticles are used as magnetic markers to perform immunoassay, i.e., to detect binding reaction between an antigen and its antibody. The antibody is labeled with ${\gamma}-Fe_2O_3\;(or\;Fe_3O_4)$ nanoparticles, and the binding reaction can be magnetically detected by measuring the magnetic field from the nanoparticles. Design and set up of the system is described. The system consists of (1) SQUID magnetometer or gradiometer made of 30-deg. bicrystal junctions, (2) field and compensation coils to apply the magnetic field of about 1 mT, (3) special Dewar to realize a 2 mm-distance between the SQUID and the sample, (4) two layers of cylindrical shielding to reduce the extemal magnetic noise to about 1/100, and (5) an electric slider to move the sample with a speed of 10 mm/sec. The sensitivity of the system is studied in terms of detectable magnetic flux. For the measurement bandwidth from 0.2 Hz to 10 Hz, minimum-detectable amplitude of the magnetic flux is $0.8\;m\;{\Phi}_o$ and $0.25\;m{\Phi}_o$ for the magnetometer and the gradiometer, respectively, when the magnetic field of 1 mT is applied. The difference between them is due to the residual environmental noise, and the applied magnetic field does not increase the system noise. The corresponding weight of the magnetic markers is 1 ng and 310 pg, respectively. An experiment is also conducted to measure antigen-antibody reaction with the present system. It is shown that the sensitivity of the present system is 10 times better than that of the conventional method using an optical marker. A one order of magnitude improvement of sensitivity will be realized by the sophistication of the present system.

  • PDF

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

외부 노이즈에 따른 초전도 CICC의 침투자장 해석 (The Analysis of Penetrated Magnetic Field in superconducting CICC according to External Noise)

  • 안민철;이승제;이찬주;김태중;고태국;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.26-28
    • /
    • 2000
  • Generally high frequency electromagnetic waves can not penetrate into waveguide, and it is called skin effect. Since the shape of superconducting CICC (Cabel In Conduit Conductor) is similar to that of waveguide, the characteristics of waveguide can be applied to CICC. In this paper, we analyzed penetrated magnetic field in CICC according to external noise. From it, noise frequency bandwidth affecting voltage tap sensor in CICC was found.

  • PDF

SQUID를 이용한 뇌 청각유발 자장의 측정 (Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices)

  • 이용호;권혁찬;김진목;박용기
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.421-428
    • /
    • 1997
  • 초전도양자간섭소자(SQUID)를 이용한 자장센서는 현재 개발된 자장센서중에서 감도가 가장 우수한 소자로서 인체의 두뇌에서 발생하는 매우 미약한 자장에 측정이 가능하다. 뇌자도측정은 현재 많이 사용되고 있는 전기적인 측정(뇌파, 뇌유발전위) 에 비해 공간분해능이 우수하고, fMRI나 PET에 비해서는 시간분해능이 우수하므로 뇌기능연구에 유용하게 사용될 수 있다. 본 연구에서는 뇌자도 측정을 위하여 4-채널 SQUID시스템을 개발하였다. 개발된 시스템의 주요 특징은 새로운 방식의 SQUID센서를 채택함으로서 간단한 회로로써 SQUID구동이 가능하도록 하였으며, 검출코일의 신뢰성을 향상시키기 위하여 집적화된 평면형 코일을 사용하였다. 외부 환경잡음을 소거하기 위하여 자기차폐실을 설치하였고, 개발된 SQUID 시스템을 이용하여 뇌의 청각령으로부터 발생하는 자기신호를 측정하였다.

  • PDF

MR유체를 이용한 스퀴즈모드 타입 마운트의 동특성 (Dynamic Properties of Squeeze Type Mount Using MR Fluid)

  • 안영공;양보석;하종용;김동조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.464-467
    • /
    • 2002
  • This paper presents investigation of damping characteristics of squeeze mode type MR (magneto-Rheological) mount experimentally. Since damping property of the MR fluid is changed by variation of the applied magnetic field strength, squeeze mode type MR mount proposed in the study has variable damping characteristics according to the applied magnetic field strength. Impact and excitation tests were performed to investigate the dynamic properties of squeeze mode type MR mount. Responses of the mount were compared in proportion to the applied magnetic field strength. The experimental results show that the mount can effectively reduce vibration amplitude in a wide frequency range by changing the applied magnetic field strength.

  • PDF

최적 요크를 갖는 자기변형 그레이팅을 이용한 고출력 주파수 튜닝 평판 SH 파 발생 (Magnetostrictive Grating with an Optimal Yoke for Generating High-Output Frequency-Tuned SH Waves in a Plate)

  • 김우철;김익규;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2007
  • The objective of this presentation is to introduce a recent development of a magnetostrictive grating technique using an optimal yoke to efficiently generate and measure SH (Shear-Horizontal) waves in a plate. Gratings are effective means to generate frequency-tuned waves, but the gap between magnetostrictive gratings inevitably obstructs magnetic flow. Because magnetic field is the main physical quantity to actuate and sense ultrasonic waves, the transducer performance is most significantly influenced by the magnetic field distribution in the strips. Thus, wave transduction efficiency can be substantially improved if better magnetic flow is formed in the strips. To improve the efficiency, the topology optimization method was used to determine an optimal yoke configuration. A series of experiments on an aluminum plate were conducted using a grating with and without the designed yoke; when the yoke was used, the signal outputs increased up to 60 %.

  • PDF

BLDC 모터의 고무 자석 형상 변형으로 인한 자계 변형 및 불평형 자기력 해석 (Distortion of Magnetic Field and Magnetic Force of a Brushless DC Motor due to Deformed Rubber Magnet)

  • 이창진;장건희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.834-839
    • /
    • 2007
  • This paper investigates the distortion of magnetic field of a brushless DC (BLDC) motor due to deformed rubber magnet. Global or local deformation of rubber magnet in the BLDC motor is mathematically modeled by using the Fourier series. Distorted magnetic field is calculated by using the finite element method, and unbalanced magnetic force are calculated by using the Maxwell stress tensor. The first harmonic deformation in the global deformation of rubber magnet generates the first harmonic driving frequency of the unbalanced magnetic force, and the rest harmonic deformations of rubber magnet except the harmonic deformation with multiple of common divisor of pole and slot introduces the driving frequencies with multiple of slot number ${\pm}1$ to the unbalanced magnetic force. However, the harmonic deformation with multiple of common divisor of pole and slot does not generate unbalanced magnetic force due to the rotational symmetry. When the rubber magnet is locally deformed, the unbalanced magnetic force has the first harmonic driving frequency and the driving frequencies with multiples of slot number ${\pm}1$.

  • PDF