A Study on High Current Rectifier Systems with Mitigated Time-Varying Magnetic Field Generation

  • Kim, Chang-Woo;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.232-233
    • /
    • 2010
  • This paper investigates occupational exposure to time-varying magnetic field generation in high power rectifier systems. Two different kinds of high power rectifier systems of 25kA are modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. In order to focus on the qualitative effect of rectifier operation, the mechanical structure of current carrying conductors is simplified as infinite long bus-bar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc side of rectifier infringing the limit from ICNIRP. The multilevel rectifier-IGCT type has almost negligible field generation from ac input side and smaller harmonic contents in dc load side complying with ICNIRP guideline. This remarkable advantage of multilevel rectifier-IGCT type can lead to very simple site layout design for installation and cost-effective compliance to guideline of occupational exposure against magnetic field.

  • PDF

Effect of a Static Magnetic Field on Susceptibility to Ethanol-Induced Hepatic Dysfunction in Rats

  • Park, Kap-Joo;Kim, Eun-Jung;Cho, Myung-Hwan;Lee, Jae-Seok
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.833-837
    • /
    • 2006
  • To determine whether alcohol-treated rat liver cells can be protected by a static magnetic field (SMF), we analyzed the blood chemistry and histology of hepatic tissue removed from alcohol-exposed rats that had been exposed to a static magnetic field. The rats were exposed to a 0.3 tesla (3,000 gauss) magnetic field (MF) for 24 hr daily for 5 weeks with appropriate controls. Glutamic pyruvic transaminase activity and the triglyceride levels in animals exposed to the north (N) or south (S) pole of the MF decreased significantly (p<0.01 and p<0.05, respectively) compared with negative control animals with alcohol exposure. A histological examination of hepatic tissue revealed a moderate to severe accumulation of fat vacuoles of various sizes in the cytoplasm of the hepatocytes of animals in the negative control group throughout the study; whereas in groups exposed to the MF poles, fewer fat vacuoles were seen compared with the negative control group. Electron microscopic observations showed that exposure to the N or S pole protected organelles, including the nucleus, from damage during exposure to this toxic agent, as indicated by the fact that the nucleus and the mithochondria virtually retained their shape throughout this study. These results suggest that exposure to a SMF could be an excellent way of protecting against alcohol-induced damage to the rat liver cell.

TLD's Glow Curve and Radiation Exposure Amount Analysis at Environment with/without Magnetic Field Exposure as Time Passing (시간 경과에 따른 자기장 노출 유·무 환경에서 열형광선량계의 글로우 곡선 및 피폭 방사선량 분석)

  • Lee, Jae-Heon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.419-426
    • /
    • 2016
  • The research is done to analyze the change of personal dosimeter according to the elapsed times(24 hours, 1 week, 2 weeks, 3 weeks, 4 weeks) and magnetic field and find out the effective exposure treatment for radiation workers. At first, research the heat treatment and radiation of grouped TLD and keep them in different environments-exposed separately to observe the consequences of glow curve and the level of radiation exposure. As a result, we could find that 24 hours passing TLD group showed the difference in glow curve and the level of radiation. This can be considered as the change caused by magnetic exposure. Also the average radiation exposure level of TLD group, unexposed to the magnetic field, was 15.41 mSv. And the average radiation exposure level of TLD group, exposed to the magnetic field, was 14.83 mSv which decreased the biggest amount(3.80%) among the other groups. If a radiation worker, who works in PET-MRI room, uses TLD as a personal dosimeter, the level of real radiation exposure caused by exposure to the magnetic field won't change significantly as recorded at a regular record cycle but with not regular record but interim record, the lower exposure dose will be appeared than the real level of radiation.

Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines (초고압 송전선로의 자계크기 해석과 실측 비교)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

The First Survey on Personal Magnetic Field Exposure of Koreans (한국인의 개인 자계 노출량 조사 (I))

  • Ju, Mun-No;Yang, Kwang-Ho;Myung, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.472-474
    • /
    • 2002
  • The objective of this survey is to characterize the personal magnetic field exposure of the Korean population. The participants in the survey on magnetic field exposure were selected randomly by occupation. In this first step survey, the number of participant is 108 and for the second step, about 400 participants will be surveyed in the near future. The survey is the first significant study that quantifies the exposure of the general population for the entire day, not only for the time spent in one's bed but also for the time at work in Korea.

  • PDF

Analysis on the relation between electric current and magnetic field near transmission lines (송전선로에서 전류와 자계의 상관관계 분석)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF

Study for Exposure Limits of Magnetic Fields in the Transformer Substation (변전소 건설로 인한 자기장 노출범위설정에 관한 연구)

  • Jeon, In-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.195-202
    • /
    • 2005
  • The health risks from the magnetic fields exposure have been brought out difficulties in the construction of transformer substation. According to several epidemiologic studies and the relevant international organizations, magnetic fields should not exceed the exposure limits of 3mG for the people living near electric power lines. The rigid regulation of the exposure levels for the elementary school and residental areas has been established already in Switzerland and Italy. Since 1998, the environmental impact assessment system in Korea has been reviewed for power-frequency magnetic field by precautionary policies. In this study, the possible application of Prior Environmental Performance Review System for the transformer substation was reviewed from the points of the properties of the powerfrequency magnetic fields. The ranges and survey methods of the assessment for the transformer substation were proposed. The ranges of magnetic fields was between 300m to 500m for the 345kV transformer substation. It is necessary to develop further specific assessment methods for various high-voltage transformer substations.

Occupational Exposure to Steady Magnetic Fields and its Effect on Workers Blood Indices at an Electrolysis Unit

  • Ravandi, Mohammad Reza Ghotbi;Mardi, Hossein;Khanjani, Narges;Barkhordari, Abolfazl
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.255-260
    • /
    • 2016
  • The health effects of environmental and occupational exposure to steady magnetic fields is a matter of concern. The aim of this study was to evaluate the hematologic effects of exposure to steady magnetic fields at the electrolysis unit of a Copper complex. The population under study was the workers of the electrolysis unit of the copper refinery. The average steady magnetic field in the exposure group was 2.5 mT. The blood indices of workers exposure to steady magnetic fields after adjusting for confounders showed decreased white blood cells (except neutrophils) and increase in the number and volume of platelets. Red blood cells did not show any significant difference. Exposure to steady magnetic fields even in proposed safe limits may have hematologic effects on humans. There is a necessity for more research about the safe doses of exposure to magnetic fields.

Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances (가전기기에서 발생되는 극저주파 과도자계 예측기법 연구)

  • Ju, Mun-No;Yang, Kwang-Ho;Myung, Sung-Ho;Min, Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields (반도체 제조 근로자의 극저주파 자기장 노출 평가)

  • Chung, Eun Kyo;Kim, Kab Bae;Chung, Kwang Jae;Lee, In Seop;You, Ki Ho;Park, Jung-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.