• Title/Summary/Keyword: Magnetic effects

Search Result 1,775, Processing Time 0.022 seconds

Comparative Study on the Viability of Frozen-thawed Primordial Germ Cells using Vitrification in Chicken Breed (초자화 동결법을 이용한 닭 품종간의 원시생식세포 동결성적의 비교)

  • Kim, Hyun;Kim, Dong Hun;Han, Jae Yong;Choi, Sung Bok;Ko, Yeoung Gyu;Do, Yoon Jung;Seong, Hwan Hoo;Kim, Sung Woo
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.207-216
    • /
    • 2013
  • This study was conducted to establish the method for preserving PGCs that enables long-term storage in liquid nitrogen for developmental engineering or preservation of species. The purpose of this study is to clarify the effects of freeze-thaw treatment on viability of PGCs in chickens. PGCs were collected separately from a germinal gonad of an early embryo of 5.5~6 day (stage 28) of Isa brown, Korean Oge (KO), White Leghorn and Commercial breeds. PGCs separated from a germinal gonad of an early embryo of 5.5~6 day (stage 28) are suspended in a freezing medium containing a freezing and protecting agents (e.g. dimethyl sulfoxide (DMSO), ethylene glycol (EG) and glycerol). The PGCs were then purified using magnetic activated cell sorting (MACS) method. The viability of PGCs after thawing was $87.4{\pm}0.4%$ and $89.4{\pm}0.2%$ with the 10% EG treatments with no significant difference between the Isa brown and Commercial breeds. The viability of PGCs after freeze- thawing was significantly higher for Isa brown ($87.4{\pm}0.4%$) and Commercial breeds ($89.4{\pm}0.2%$) than Korean Oge (KO) ($77.6{\pm}1.1%$) and White Leghorn ($76.2{\pm}0.9%$)(p<0.05) using 10% EG cryoprotectant. This study established a method for pre- serving chicken PGCs that enables systematic storage and labeling of cryopreserved PGCs in liquid ($LN_2$) at agermplasm repository and ease of entry into a data base. In the future, the importance for this new technology is that poultry lines can be conserved while work is being conducted on improving the production of germline chimeras.

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

Reaction Gas Composition Dependence on the Properties of SnO2 Films on PET Substrate by ECR-MOCVD (반응가스조성이 PET기판위에 ECR 화학증착법에 의해 제조된 SnO2 박막특성에 미치는 영향)

  • Kim, Yun-Seok;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.3
    • /
    • pp.139-145
    • /
    • 2005
  • [ $SnO_x$ ] films on the flexible substrate of PET film were prepared at ambient temperature under a $(CH_3)_4Sn(TMT: tetra-methyl tin)-H_2-O_2$ atmosphere in order to obtain transparent conductive polymer by using ECR-MOCVD(Electro Cyclotron Resonance Metal Organic Chemical Yfpor Deposition) system. The prepared $SnO_x$ thin films show generally over $90\%$ of optical transmittance at wavelength range of 380-780nm and about $1\times10^{-2\~3}ohm{\cdot}cm$ of electrical resistivity. In the present study, effects of $O_2/TMT\;and\;H_2/TMT$ mole ratio on the properties of $SnO_x$ films are investigated and the other process parameters such as microwave power, magnetic current power, substrate distance and working pressure are fixed. Based on our experimental results, the $SnO_x$ film composition ratio of Sn and O directly influences on the electrical and optical properties of the films prepared. The $SnO_x$ film with low electric resistivity and high transmittance could be obtained by controlling the process parameters such as $O_2/TMT\;and\;H_2/TMT$ mole ratio, which play an important role to change the composition ratio between Sn and O. An increase of $O_2/TMT$ mole ratio brought on the increases 0 content in the $SnO_x$ film. On the other hand, an increase of $H_2/TMT$ mole ratio lead to decreases the oxygen content in the film. The optimized composition ratio of oxygen : tin Is determined as 2.4: 1 at $O_2/TMT$ of 80 and $H_2/TMT$ of 40 mole ratio, respectively.

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

Ginsenosides from the fruits of Panax ginseng and their cytotoxic effects on human cancer cell lines (인삼(Panax ginseng) 열매로부터 분리한 ginsenoside의 동정 및 암세포독성 효과)

  • Gwag, Jung Eun;Lee, Yeong-Geun;Hwang-Bo, Jeon;Kim, Hyoung-Geun;Oh, Seon Min;Lee, Dae Young;Baek, Nam-In
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.4
    • /
    • pp.371-377
    • /
    • 2018
  • The fruits of Panax ginseng were extracted with 80% aqueous MeOH and the concentrates were partitioned into EtOAc, n-BuOH, and $H_2O$ fractions. The repeated $SiO_2$ and octadecyl $SiO_2$ column chromatographies for the EtOAc fraction led to isolation of five ginsenosides. The chemical structures of these compounds were determined as ginsenoside F1 (1), ginsenoside F2 (2), ginsenoside F3 (3), ginsenoside Ia (4), notoginsenoside Fe (5) based on spectroscopic analyses including nuclear magnetic resonance, MS, and infrared. Compounds 2-5 were isolated for the first time from the fruits of P. ginseng in this study. All isolated compounds were evaluated for cytotoxic activities against human cancer cell lines such as HCT-116, SK-OV-3, human cervix adenocarcinoma (HeLa), HepG2, and SK-MEL-5. Among them compounds 2, 4, and 5 showed significant cytotoxicity on cancer cells. Compound 2 exhibited cytotoxicity on SK-MEL-5, HepG2, and HeLa cells with $IC_{50}$ values of 82.8, 86.8, and $78.3{\mu}M$, respectively. Compound 4 showed cytotoxicity on HCT-116, SK-MEL-5, SK-OV-3, HepG2, and HeLa cells with $IC_{50}$ values of 24.5, 25.4, 26.3, 22.0, and $24.9{\mu}M$, respectively. Compound 5 did on SK-MEL-5 cell with $IC_{50}$ value of $81.7{\mu}M$. The cytotoxicity of ginsenoside 2, 4, and 5 isolated from the fruits of Panax ginseng showed strong inhibition effect against on cancer cells, all of which have a glucopyranosyl moiety on C-3.