• Title/Summary/Keyword: Magnetic distribution

Search Result 1,300, Processing Time 0.026 seconds

3D Inversion of Aeromagnetic Data In an Area of Geumsan (금산지구 항공 자력탐사 자료의 3차원 역산)

  • Ko, Kwang-Beom;You, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.49-57
    • /
    • 2014
  • 3D magnetic inversion, based on the assemblage of 2D forward modeling and inversion as a practical technique to reflect the a priori information, was conducted to investigate the spatial distribution features of black-shale related and pyrometamorphic uranium deposit and several lithological units of Ogcheon Super Group in an area of Geumsan. By using the 3D visualization technique with suitable susceptibility interval and horizontal slice map, the spatial distribution of magnetic susceptibility corresponded to the black shale related uranium bearing lithological units, Black Slate member was well coincided with a information of uranium deposit. Also, even though it is indirect indicator for the detetction of uranium deposits interbedded in Gray Hornfels member, spatial susceptibility distribution which shows the south-east magnetic linearment corresponding to the Majeon-ri formation and Dark Gray Slate were matched well. From this investigation, we inferred that maximum depth extension which Black Slate member can be separately recognized with respect to adjacent Dark Gray Slate with strong magnetic susceptibility anomaly is about 150m with reference elevation level of 306m. In addition, Majeon-ri formation located south of Black Slate member revels relatively high magnetic susceptibility range but shows high spatial susceptibility fluctation. And, as an intrusive rocks, Jurassic Biotite Granite shows relatively low magnetic susceptibility characteristics. On the contrary, Cretaceous granite distributed in soutthern part of the study area shows the relatively high susceptibility distribution.

GENERATION OF MAGNETIC FIELDS BY TEMPERATURE GRADIENTS

  • OKABE NOBUHIRO;HATTORI MAKOTO
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.547-551
    • /
    • 2004
  • We showed that magnetic fields are generated in the plasma which have the temperature inhomogeneities. The mechanism is the same as the Weibel instability because the velocity distribution functions are at non-equilibrium and anisotropic under the temperature gradients. The growth timescale is much shorter than the dynamical time of structure formation. The coherence length of magnetic fields at the saturated time is much shorter than kpc scale and then, at nonlinear phase, become longer by inverse-cascade process. We report the application of our results to clusters of galaxies, not including hydrodynamic effects.

The Manufacture and Technology of the Ferrite Materials in China

  • Ying Li;Huiping Shao;Huang, Yu-Qiang
    • Resources Recycling
    • /
    • v.11 no.5
    • /
    • pp.11-15
    • /
    • 2002
  • China is a large country fer the production of magnetic materials because of its cheap price and abundant raw materials. The total yield of ferrite occupies about 20% fraction in the market of the world. In this report, the characteristics and the yield of the ferrite magnet produced in China were displayed. Also the distribution of manufacturers and research institutes and the Chinas 10th five-year-plan on the magnetic materials were reviewed.

Preparation and Physical Characterizations of Superparamagnetic Maghemite Nanoparticles

  • Yoon, Sunghyun
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.323-326
    • /
    • 2014
  • Superparamagnetic maghemite nanoparticles were prepared by chemical co-precipitation, followed by a temperate oxidation stage, and investigated using FE-SEM, XRD, TGA, VSM, and M$\ddot{o}$ssbauer spectroscopy. Through SEM image and XRD analysis, its average particle size was found to be 13.9 nm. While VSM magnetic measurement showed typical superparamagnetic behavior at room temperature, M$\ddot{o}$ssbauer spectroscopic investigation revealed that non-vanishing magnetic hyperfine structure were retained. Cation distribution estimated from M$\ddot{o}$ssbauer spectroscopy confirmed the formation of maghemite nanophase in the sample.

Design of Magnetic Circuit for Orientation of a Plastic Magnet (플라스틱 자석 배향용 자기회로 설계)

  • Kim, Chang-Eob;Kim, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.183-185
    • /
    • 1998
  • In this paper, a magnetic circuit of plastic magnet roller for laser printer is presented. The magnetization direction of plastic magnet is decided by the flux distribution of injection mold during the manufacturing process. The injection mold is designed and analysed to fit the design specification. The experiment showed that the flux distribution of a magnet is good agreement of the given specification.

  • PDF

Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field

  • Jung, Nuri Hyun;Shin, Youngseob;Jung, In-Hye;Kwak, Jungwon
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.226-232
    • /
    • 2015
  • Purpose: Toxicity of mucosa is one of the major concerns of radiotherapy (RT), when a target tumor is located near a mucosal lined organ. Energy of photon RT is transferred primarily by secondary electrons. If these secondary electrons could be removed in an internal cavity of mucosal lined organ, the mucosa will be spared without compromising the target tumor dose. The purpose of this study was to present a RT dose reduction in near target inner-surface (NTIS) of internal cavity, using Lorentz force of magnetic field. Materials and Methods: Tissue equivalent phantoms, composed with a cylinder shaped internal cavity, and adjacent a target tumor part, were developed. The phantoms were irradiated using 6 MV photon beam, with or without 0.3 T of perpendicular magnetic field. Two experimental models were developed: single beam model (SBM) to analyze central axis dose distributions and multiple beam model (MBM) to simulate a clinical case of prostate cancer with rectum. RT dose of NTIS of internal cavity and target tumor area (TTA) were measured. Results: With magnetic field applied, bending effect of dose distribution was visualized. The depth dose distribution of SBM showed 28.1% dose reduction of NTIS and little difference in dose of TTA with magnetic field. In MBM, cross-sectional dose of NTIS was reduced by 33.1% with magnetic field, while TTA dose were the same, irrespective of magnetic field. Conclusion: RT dose of mucosal lined organ, located near treatment target, could be modulated by perpendicular magnetic field.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

Fundamental Research on Polishing of Glass Plates by Coated-type Magnetic Abrasives (자성체 피복형 연마입자를 이용한 유리의 평면 래핑의 기초 연구)

  • Moon, Bong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.108-112
    • /
    • 2011
  • In order to obtain excellent flatness and surface roughness of glass substrate disk, uniform distribution of abrasives should be important for uniform polishing. We introduced coated-type magnetic abrasives and magnetic field to a lapping for the improvement of surface roughness and removal rate. Polishing properties with the conventional diamond abrasives and the coated-type magnetic abrasives were compared. As a result, the coated-type magnetic abrasives showed small surface roughness and large removal rate by applying magnetic field. And it also was shown that coated-type magnetic abrasives could save the more amount of polishing liquid under the same removal rate than the conventional diamond abrasives can.

Yoke Topology Optimization of the Bias Magnetic System in a Magnetostrictive Sensor (자기변형 센서 바이어스 자기계의 요크 위상최적설계)

  • Kim, Yoon-Young;Kim, Woo-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.923-929
    • /
    • 2004
  • A magnetostrictive sensor is a sensor measuring elastic waves. Because of its unique non-contact measurement feature, the sensor receives more attentions in recent years. These sensors have been mainly used to measure longitudinal and torsional waves in ferromagnetic waveguides, but there increases an interest in using the sensor for flexural wave measurement. Since the performance of the sensor is strongly influenced by the applied bias magnetic field distribution, the design of the bias magnetic system providing the desired magnetic field is critical. The motivation of this investigation is to design a bias magnetic system consisting of electromagnets and yokes and the specific objective is to formulate the design problem as a bias yoke topology optimization. For the formulation, we employ linear magnetic behavior and examine the optimized results for electromagnets located at various locations. After completing the design optimization, we fabricate the prototype of the proposed bias magnetic system, and test its performance through flexural wave measurements.

Optimal Angle Error Reduction of Magnetic Position Sensor by 3D Finite Element Method

  • Kim, Ki-Chan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.454-459
    • /
    • 2013
  • This paper deals with an optimal angle error reduction method of magnetic position sensor using hall effect elements. The angle detection simulation for the magnetic position sensor is performed by 3 dimensional finite element method and Taguchi method, one of the design of experiments. The magnetic position sensor is required to generate ideal sine and cosine waveforms from its hall effect elements according to rotation angle for precise angle information. However, the output signals are easy to include harmonics due to uneven magnetic field distribution from permanent magnet in the air-gap in the vicinity of hall effect elements. For the Taguchi method, three design parameters related to position of hall effect elements and shape of back yoke are selected. The characteristics of optimal magnetic position sensor are compared with those of original one in terms of simulation as well as experiment. Finally, the performances of the motor adopting original model and optimal model are represented for the purpose of verification of motor performance due to signals from magnetic position sensor.