• Title/Summary/Keyword: Magnetic distribution

Search Result 1,292, Processing Time 0.027 seconds

Analysis of the monopole antenna characteristcs of handy phone using Finite Difference Time Domain(FDTD) Method (시간영역 유한차분법을 이용한 휴대용 전화기의 모노폴 안테나 특성해석)

  • 손영수;윤현보
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.3
    • /
    • pp.3-14
    • /
    • 1995
  • The broadband input impedance, the input power and the radiation pattern of the monopole antenna attached to the handy phone operated at 800MHz are calculated by using the Finite Difference Time Domain(FDTD) Method. For the FDTD analysis of frequency characteristics of monopole antenna, the handy phone is modeled with the geometry that the monopole antenna is connected to a conducting box, and the modified FDTD algorithm[11] used the thin wire appproximation method and the Maxwell's integral equation from the original Yee algorithm is applied for the analysis of the wire structure. Also, by means of finding the current distribution directly from circumferencial magnetic filelds around the monopole antenna and the conducting box, the radiation pattern is calculated to observe the influence of the conducting box, and is compared with the results of the known mothod for the FDTD calculation of radiation pattern, For the experiments, the handy phone of which full length including antenna is .lambda. $\lambda$/2 is manufactured and we confirm that all computation results are agree well with the mea- sured values.

  • PDF

IR Camera Technique Application for Evaluation of Gas Turbine Blades Covering Integrity (가스터빈의 코팅층 건정성 평가를 위한 적외선 열화상 카메라 기법 활용)

  • Kim J.Y.;Yang D.J.;Choi C.J.;Park S.G.;Ahn Y.S.;Jeong G.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.192-196
    • /
    • 2005
  • Key part of main equipment in a gas turbine may be likely to be damaged due to operation under high temperature, high pressure, high-speed rotation, etc. Accordingly, the cost for maintenance increases and the damaged parts may cause generation to stop. The number of parts for maintenance also increases, but diagnostics technology fur the maintenance actually does not catch up with the demand. Blades are made of precipitation hardening Ni superalloy IN738 and the like for keeping hot strength. The surface of a blade is thermal-sprayed, using powder with main compositions such as Ni, Cr, Al, etc. in order to inhibit hot oxidation. Conventional regular maintenance of the coating layer of a blade is made by FPI (Fluorescent Penetrant Inspection) and MTP (Magnetic Particle Testing). Such methods, however, are complicated and take long time and also require much cost. In this study, defect diagnostics were tested for the coating layer of an industrial gas turbine blade, using an infraredthermography camera. Since the infrared thermography method can check a temperature distribution on a wide range of area by means of non-contact, it can advantageously save expenses and time as compared to conventional test methods. For the infrared thermography method, however, thermo-load must be applied onto a tested specimen and it is difficult to quantify the measured data. To solve the problems, this essay includes description about producing a specimen of a gas turbine blade (bucket), applying thermo-load onto the produced specimen, photographing thermography images by an infrared thermography camera, analyzing the thermography images, and pre-testing for analyzing defects on the coating layer of the gas turbine blade.

  • PDF

Carbon-13 Nuclear Magnetic Resonance Spectroscopic Studies of $^{13}CO$ Adsorbed on Platinum Particles in L-Zeolites

  • 한옥희;Gustavo Larsen;Gary L. Haller;Kurt W. Zilm
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.9
    • /
    • pp.934-942
    • /
    • 1998
  • $^13CO$ chemisorbed on platinum particles in L-zeolite has been investigated by static and magic angle spinning NMR spectroscopy. The representative spectra are composed of a broad asymmetric peak with a center of gravity at 230±30 ppm and a sharp symmetric peak at 124±2 ppm which is tentatively assigned to physisorbed $CO_2$, on inner walls of L-zeolite. Overall, the broad resonance component is similar to our previous results of highly dispersed (80-96%) CO/Pt/silica or CO/Pt/alumina samples, still showing metallic characters. The principal difference is in the first moment value. The broad peak in the spectra is assigned to CO linearly bound to Pt particles in the L-zeolites, and indicates a distribution of isotropic shifts from bonding site to bonding site. The NMR results reported here manifest that the Pt particles inside of the L-zeolites channels are not collectively the same with the ones supported on silica or alumina with similar dispersion in terms of Pt particle shape and/or ordering of Pt atoms in a particle. As a result, Pt particles of CO/Pt/L-zeolite were agglomerated accompanying CO desorption upon annealing. There were no definite changes in the NMR spectra due to differences of exchanged cations. Comparison of our observation on CO/Pt/L-zeolite with Sharma et al.'s reveals that even when the first moment, the linewidtb, and the relaxation times of the static spectra and the dispersion measured by chemisorption are similar, the properties of Pt particles can be dramatically different. Therefore, it is essential to take advantage of the strengths of several techniques together in order to interpret data reliably, especially for the highly dispersed samples.

Poly(ε-caprolactone) Microcapsule with Encapsulated Nifedipine Prepared by Magnetic Stirrer

  • Lee, Hyeran;Lee, Deuk Yong;Song, Yo-Seung;Kim, Bae-Yeon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.7-14
    • /
    • 2019
  • The microencapsulation of nifedipine (NF) with 4 wt% of poly(${\varepsilon}-caprolactone$) (PCL)/polyvinylpyrollidone (PVP) or PCL/polyethylene glycol (PEG) was carried out by solvent evaporation method in oil in water emulsion system to investigate the effect of PVP and PEG addition on drug release behavior of the microcapsules. The PVA (emulsifier) concentration of 1.0 wt% was chosen for the formation of PCL capsule having an average size of $154{\pm}25{\mu}m$ due to nearly spherical shape with a narrow size distribution. As PCL/PVP and PCL/PEG ratios were raised from 10/0 to 6/4, the capsule size increased gradually from $154{\pm}25{\mu}m$ to $236{\pm}32{\mu}m$ and $248{\pm}56{\mu}m$, respectively. The drug release rate of PCL/PVP and PCL/PEG capsules increased dramatically from 0 to 4 h at the beginning and then reached the plateau region from 20 h. As the concentration of PVP or PEG increased, the amount of drug release increased, suggesting that the larger capsule size was attributed to the higher drug content. However, the drug release behavior remained almost constant. The PCL capsules exhibited no evidence of causing cell lysis or toxicity regardless of NF loading, implying that the microcapsules are clinically suitable for use as drug delivery systems.

18F-THK5351 PET Imaging in Nonfluent-Agrammatic Variant Primary Progressive Aphasia

  • Yoon, Cindy W;Jeong, Hye Jin;Seo, Seongho;Lee, Sang-Yoon;Suh, Mee Kyung;Heo, Jae-Hyeok;Lee, Yeong-Bae;Park, Kee Hyung;Okamura, Nobuyuki;Lee, Kyoung-Min;Noh, Young
    • Dementia and Neurocognitive Disorders
    • /
    • v.17 no.3
    • /
    • pp.110-119
    • /
    • 2018
  • Background and Purpose: To analyze $^{18}F-THK5351$ positron emission tomography (PET) scans of patients with clinically diagnosed nonfluent/agrammatic variant primary progressive aphasia (navPPA). Methods: Thirty-one participants, including those with Alzheimer's disease (AD, n=13), navPPA (n=3), and those with normal control (NC, n=15) who completed 3 Tesla magnetic resonance imaging, $^{18}F-THK5351$ PET scans, and detailed neuropsychological tests, were included. Voxel-based and region of interest (ROI)-based analyses were performed to evaluate retention of $^{18}F-THK5351$ in navPPA patients. Results: In ROI-based analysis, patients with navPPA had higher levels of THK retention in the Broca's area, bilateral inferior frontal lobes, bilateral precentral gyri, and bilateral basal ganglia. Patients with navPPA showed higher levels of THK retention in bilateral frontal lobes (mainly left side) compared than NC in voxel-wise analysis. Conclusions: In our study, THK retention in navPPA patients was mainly distributed at the frontal region which was well correlated with functional-radiological distribution of navPPA. Our results suggest that tau PET imaging could be a supportive tool for diagnosis of navPPA in combination with a clinical history.

Design and Electromagnetic Analysis of a 15 MW Class Superconducting Wind Power Generator (15 MW급 초전도 풍력 발전기의 설계 및 전자기 해석)

  • Jung, Ga-Eun;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.39-44
    • /
    • 2019
  • A high-temperature superconducting(HTS) generators have been actively studied because of its advantages of weight, size, and efficiency. A large-scale superconducting wind power generator becomes a very low-speed high-torque rotating machine. In these machines, high electromagnetic force and torque are important issued. Two generators connected in series on one shaft design are one of the solution to overcome the high torque problem. In this paper, the authors design and analyze a 15 MW class HTS generator. The 15 MW HTS generator is confirmed in terms of magnetic field distribution and torque performance using a 3D finite element method. As a result, the designed generators generates less torque than a conventional generator. The designed 15 MW superconducting generator will be effectively utilized in the construction of the large-scale wind power generation system.

18F-THK5351 PET Imaging in the Behavioral Variant of Frontotemporal Dementia

  • Nam, Gijin;Jeong, Hye Jin;Kang, Jae Myeong;Lee, Sang-Yoon;Seo, Seongho;Seo, Ha-Eun;Park, Kee Hyung;Yeon, Byeong Kil;Ido, Tatsuo;Shin, Dong Jin;Noh, Young
    • Dementia and Neurocognitive Disorders
    • /
    • v.17 no.4
    • /
    • pp.163-173
    • /
    • 2018
  • Background and Purpose: Behavioral variant frontotemporal dementia (bvFTD) is a subtype of frontotemporal dementia, which has clinical symptoms of progressive personality and behavioral changes with deterioration of social cognition and executive functions. The pathology of bvFTD is known to be tauopathy or TDP-43 equally. We analyzed the $^{18}F-THK5351$ positron emission tomography (PET) scans, which were recently developed tau PET, in patients with clinically-diagnosed bvFTD. Methods: Forty-eight participants, including participants with behavioral variant frontotemporal dementia (bvFTD, n=3), Alzheimer's disease (AD, n=21) and normal cognition (NC, n=24) who completed 3T magnetic resonance images, $^{18}F-THK5351$ PET scans, and detailed neuropsychological tests were included in the study. Voxel-wise statistical analysis and region of interest (ROI)-based analyses were performed to evaluate the retention of THK in bvFTD patients. Results: In the voxel-based and ROI-based analyses, patients with bvFTD showed greater THK retention in the prefrontal, medial frontal, orbitofrontal, anterior cingulate, insula, anterior inferior temporal and striatum regions compared to NC participants. Left-right asymmetry was noted in the bvFTD patients. A patient with extrapyramidal symptoms showed much greater THK retention in the brainstem. Conclusions: The distribution of THK retention in the bvFTD patients was mainly in the frontal, insula, anterior temporal, and striatum regions which are known to be the brain regions corresponding to the clinical symptoms of bvFTD. Our study suggests that $^{18}F-THK5351$ PET imaging could be a supportive tool for diagnosis of bvFTD.

A New Classification for Cervical Ossification of the Posterior Longitudinal Ligament Based on the Coexistence of Segmental Disc Degeneration

  • Lee, Jun Ki;Ham, Chang Hwa;Kwon, Woo-Keun;Moon, Hong Joo;Kim, Joo Han;Park, Youn-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.69-77
    • /
    • 2021
  • Objective : Classification systems for cervical ossification of the posterior longitudinal ligament (OPLL) have traditionally focused on the morphological characteristics of ossification. Although the classification describes many clinical features associated with the shape of the ossification, including the concept of spondylosis seems necessary because of the similarity in age distribution. Methods : Patients diagnosed with OPLL who presented with increase signal intensity (ISI) on magnetic resonance imaging were surgically treated in our department. The patients were divided into two groups (pure versus degenerative) according to the presence of disc degeneration. Results : Of 141 patients enrolled in this study, more than half (61%) were classified into the degenerative group. The pure group showed a profound male predominance, early presentation of myelopathy, and a different predilection for ISI compared to the degenerative group. The mean canal compromise ratio (CC) of the ISI was 47% in the degenerative group versus 61% in the pure group (p<0.0000). On the contrary, the global and segment motions were significantly larger in the degenerative group (p<0.0000 and p=0.003, respectively). The canal diameters and global angles did not differ between groups. Conclusion : Classifying cervical OPLL based on the presence of combined disc degeneration is beneficial for understanding the disorder's behavior. CC appears to be the main factor in the development of myelopathy in the pure group, whereas additional dynamic factors appear to affect its development in the degenerative group.

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

Numerical Analysis of Moving Type and Static Type Electrodynamic Suspension Simulator with Superconducting Levitation Magnet (초전도 부상자석을 이용한 동적 및 정지형 반발식 자기부상 시험기의 수치해석)

  • Lee, E.R.;Bae, D.K.;Chung, Y.D.;Yoon, Y.S.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • This paper presents the numerical simulation results on the moving type electrodynamic suspension (EDS) simulator and static type EDS simulator using high-Tc superconducting (HTS) levitation magnet. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible two ways to simulate the EDS system were simulated in this paper by using finite element method (FEM). The first way was the moving type simulator which consists of the fixed HTS magnet and the moving ground conductor. The second way was the static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.