• 제목/요약/키워드: Magnetic distribution

Search Result 1,292, Processing Time 0.037 seconds

Preparation and Characterization of Unsaturated Poly(3-hydroxyalkanoate) Nanoparticles (불포화 폴리히드록시알칸오에이트 나노입자의 제조 및 특성)

  • 한정현;김승수;신병철;이영하;홍성욱
    • Polymer(Korea)
    • /
    • v.27 no.6
    • /
    • pp.542-548
    • /
    • 2003
  • Nanoparticles with unsaturated poly(hydroxyalkanoate)s (UPHAs) biosynthesized with Pseudo-monas oleovorans were prepared by spontaneous emulsification solvent diffusion method. The influence of nanoparticle formation was investigated with various experimental parameters such as sonication conditions, sol-vent, surfactant and polymer contents, etc. The physical and chemical properties of UPHAS and its nanoparticles were characterized using $^1$H- and $\^$13/C-nuclear magnetic resonance spectroscopies, attenuated total reflection infrared spectroscopy, differential scanning calorimetry and gel permeation chromatography. The morphology of particles was observed using scanning electron microscope and the size and distribution of nanoparticles were measured with electrophoretic light scattering spectrophotometer. The mean diameter of particles decreased with increasing sonication amplitude and time. The addition of ethanol into UPHAS chloroform solution decreased the particle size presumably due to increased solvent diffusion into water phase. The particle size increased with increased the concentration of UPHAS solution. Under the 2-4% poly(vinyl alcohol) (PVA) aqueous solution the minimum mean diameter of particles was shown. The higher degree of hydrolysis and degree of polymerization of PVA increased the mean diameter of particles.

Mössbauer Study of AIFeO3 (AIFeO3 물질의 Mössbauer 분광학적 연구)

  • We, Jee-Hoon;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.14-17
    • /
    • 2006
  • [ $AIFeO_3$ ]has been studied by x-ray diffraction (XRD), vibrating sample magnetometer, Mossbauer spectroscopy. The crystal structure is found to orthorhombic with the lattice parameters being $a_0=4.983\;{\AA},\;b_0=8.554\;{\AA},\;c_0=9.239\;{\AA}$, Magnetic hysteresis curve for $AIFeO_3$ showed weakly ferromagnetic phase at room temperature and a asymmetric shape dependent on the direction of applied field at low temperature. The Curie temperature determined by the temperature dependence of magnetization is 250 K. Mossbauer spectra of $AIFeO_3$ have been taken from 4.2 K to 295 K. Isomer shift at room temperature are found to be $0.11\~0.32\;mm/s$, which is consistent with ferric state. The absorption lines widths become broader with increasing temperature, which is attributed to the Fe ions distribution of each cation site and anisotropy energy difference of each sublattice.

An Average Shape Model for Segmenting Prostate Boundary of TRUS Prostate Image (초음파 전립선 영상에서 전립선 경계 분할을 위한 평균 형상 모델)

  • Kim, Sang Bog;Chung, Joo Young;Seo, Yeong Geon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.5
    • /
    • pp.187-194
    • /
    • 2014
  • Prostate cancer is a malignant tumor occurring in the prostate. Recently, the repetition rate is increasing. Image inspection method which we can check the prostate structure the most correctly is MRI(Magnetic Resonance Imaging), but it is hard to apply it to all the patients because of the cost. So, they use mostly TRUS(Transrectal Ultrasound) images acquired from prostate ultrasound inspection and which are cheap and easy to inspect the prostate in the process of treating and diagnosing the prostate cancer. Traditionally, in the hospital the doctors saw the TRUS images by their eyes and manually segmented the boundary between the prostate and nonprostate. But the manually segmenting process not only needed too much time but also had different boundaries according to the doctor. To cope the problems, some automatic segmentations of the prostate have been studied to generate the constant segmentation results and get the belief from patients. In this study, we propose an average shape model to segment the prostate boundary in TRUS prostate image. The method has 3 steps. First, it finds the probe using edge distribution. Next, it finds two straight lines connected with the probe. Finally it puts the shape model to the image using the position of the probe and straight lines.

Clinical Study of the Treatment of Spondylolisthesis with Lumbar Herniated Intervertebral Disc (요추 추간판 탈출증을 동반한 척추전방전위증의 한방치료에 관한 임상적 고찰)

  • Kim, Tae-Ho;Yoon, Tae-Kyung;Yun, Young-Ung;Jeong, Seon-Yeong;Lee, Cha-Ro
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.1
    • /
    • pp.15-26
    • /
    • 2014
  • Objectives : The purpose of this study was to evaluate the effect of Korean medicicine treatment in patients with Spondylolisthesis and Lumbar Herniated Intervertebral Disc(HIVD). Methods : This clinical study was carried out on 62 patients who were diagnosed as spondylolisthesis and lumbar herniated intervertebral disc(HIVD) on L-spine X-ray and L-spine magnetic resonance imaging(MRI), who had been admitted from Feb. 2013 to Apr. 2014. All of 62 patients were treated with acupuncture, chuna treatment and herbal medicine during the whole admission period. Numerical rating scale(NRS) was used to evaluated the effectiveness of the oriental medical treatment. Results : 1. Distribution showed female predominance in general. 2. Degenerative type is the most common in this study. 3. In the duration of symptoms, the largest group was" Subacute"(32.26%). 4. Almost of patients had radiation pain, but in SLR test and valsalva test, more patients had no significant sign. 5. Spondylolytic type involved the 5th lumbar vertebra in 80% and degenerative type involved the 4th lumbar vertebra in 53.84%. 6. Most of case were grade 1(93.54%) in degree of slipping. 7. By the oriental medical treatment, NRS reduction in spondylolytic spondylolisthesis, was better than degenerative spondylolisthesis. Conclusions : The result of treatment by Korean medical is satisfactory for the tretment of spondylolisthesis.

  • PDF

Analysis of Equivalent Circuit Approach for Ridge Type CPW Traveling - Wave Structure (릿지 형태 CPW 진행파형 구조의 등가회로 분석)

  • 윤상준;공순철;옥성해;윤영설;구민주;박상현;최영완
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.45-54
    • /
    • 2004
  • Microwave characteristics of ridge type CPW traveling-wave(TW) electroabsorption modulator and photodetector are affected by the thickness of intrinsic layer, width of guiding layer, and the separation of signal and ground electrodes. These factors are determined effective index of microwave and characteristic impedance due to changing of capacitance(C) and inductance(L) of device. However, conventional equivalent circuit of TW-structure is approximated to microstrip and CPW transmission line by distribution of electric and magnetic fields, respectively. In this paper, we analyzed microwave characteristics of TW-structure and found more accurate value of C and L by using finite difference time domain (FDTD) method. These values are adopted circuit element of equivalent circuit. Microwave characteristics obtained by the FDTD and equivalent circuit model show good agreement.

Polystyrene-b-poly(oligo(ethylene oxide) Monomethyl Ether Methacrylate)-b-polystyrene Triblock Copolymers as Potential Carriers for Hydrophobic Drugs

  • You, Qianqian;Chang, Haibo;Guo, Qipeng;Zhang, Yudong;Zhang, Puyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.558-564
    • /
    • 2013
  • A simple and effective method is introduced to synthesize a series of polystyrene-b-poly(oligo(ethylene oxide) monomethyl ether methacrylate)-b-polystyrene (PSt-b-POEOMA-b-PSt) triblock copolymers. The structures of PSt-b-POEOMA-b-PSt copolymers were characterized by Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance ($^1H$ NMR) spectroscopy. The molecular weight and molecular weight distribution of the copolymer were measured by gel permeation chromatography (GPC). Furthermore, the self-assembling and drug-loaded behaviours of three different ratios of PSt-b-POEOMA-b-PSt were studied. These copolymers could readily self-assemble into micelles in aqueous solution. The vitamin E-loaded copolymer micelles were produced by the dialysis method. The micelle size and core-shell structure of the block copolymer micelles and the drug-loaded micelles were confirmed by dynamic light scattering (DLS) and transmission electron microscopy (TEM). The thermal properties of the copolymer micelles before and after drug-loaded were investigated by different scanning calorimetry (DSC). The results show that the micelle size is slightly increased with increasing the content of hydrophobic segments and the micelles are still core-shell spherical structures after drug-loaded. Moreover, the glass transition temperature (Tg) of polystyrene is reduced after the drug loaded. The drug loading content (DLC) of the copolymer micelles is 70%-80% by ultraviolet (UV) photolithography analysis. These properties indicate the micelles self-assembled from PSt-b-POEOMA-b-PSt copolymers would have potential as carriers for the encapsulation of hydrophobic drugs.

Study of the Kinetic Effects on Relativistic Unmagnetized Shocks using 3D PIC Simulations

  • Choi, Eun Jin;Min, Kyoung W.;Choi, Cheongrim;Nishikawa, Ken-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.101.2-101.2
    • /
    • 2012
  • Shocks are ubiquitous in astrophysical plasmas: bow shocks are formed by the interaction of solar wind with planetary magnetic fields, and supernova explosions and jets produce shocks in interstellar and intergalactic spaces. The global morphologies of these shocks are usually described by a set of magnetohydrodynamic (MHD) equations which tacitly assumes local thermal equilibrium, and the resulting Rankine-Hugoniot shock jump conditions are applied to obtain the relationship between the upstream and downstream physical quantities. While thermal equilibrium can be achieved easily in collisional fluids, it is generally believed that collisions are infrequent in astrophysical settings. In fact, shock widths are much smaller than collisional mean free paths and a variety of kinetic phenomena are seen at the shock fronts according to in situ observations of planetary shocks. Hence, both the MHD and kinetic equations have been adopted in theoretical and numerical studies to describe different aspects of the physical phenomena associated with astrophysical shocks. In this paper, we present the results of 3D relativistic particle-in-cell (PIC) simulations for ion-electron plasmas, with focus on the shock structures: when a jet propagates into an unmagnetized ambient plasma, a shock forms in the nonlinear stage of the Weibel instability. As the shock shows the structures that resemble those predicted in MHD systems, we compare the results with those predicted in the MHD shocks. We also discuss the thermalization processes of the upstream flows based on the time evolutions of the phase space and the velocity distribution, as well as the wave spectra analyses.

  • PDF

AC transport current loss analysis for anti-parallel current flow in face-to-face stacks of superconducting tapes

  • Yoo, Jaeun;Han, Young-Hee;Kim, Hey-Rim;Park, Byung-Jun;Yang, Seong-Eun;Kim, Heesun;Yu, Seung-Duck;Park, Kijun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.42-46
    • /
    • 2014
  • In this study we investigated ac transport current losses in the face to face stack for the anti-parallel current flow, and compared the electromagnetic properties with those of the single SC tape as well as those of the same stack for the parallel current path. The gap between the SC tapes in the stack varied in order to verify the electromagnetic influence of the neighbors when current flows in opposite direction, and the model was implemented in the finite element method program by the commercial software, COMSOL Multiphysics 4.2a. Conclusively speaking, the loss was remarkably decreased for the anti-parallel current case, which is attributed the magnetic flux compensation between the SC layers due to the opposite direction of the current flows. As the gap between SC tapes was increased, the loss mitigation became less effective. Besides, the current density distribution is very flat cross the sample width for the narrower gap case, which is believed to be benefit for the power electric system. These results are all in good agreement with those predicted theoretically for an infinite bifilar stack.

Tc and Jc distribution in in situ processed MgB2 bulk superconductors with/without C doping

  • Kim, C.J.;Kim, Y.J.;Lim, C.Y.;Jun, B.H.;Park, S.D.;Choo, K.N.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.36-41
    • /
    • 2014
  • Temperature dependence of magnetic moment (m-T) and the magnetization (M-H) at 5 K and 20 K of the in situ processed $MgB_2$ bulk pellets with/without carbon (C) doping were examined. The superconducting critical temperature ($T_c$), the superconducting transition width (${\delta}T$) and the critical current density ($J_c$) were estimated for ten test samples taken from the $MgB_2$ bulk pellets. The reliable m-T characteristics associated with the uniform $MgB_2$ formation were obtained for both $MgB_2$ pellets. The $T_cs$ and ${\delta}Ts$ of all test samples of the undoped $MgB_2$ were the same each other as 37.5 K and 1.5 K, respectively. The $T_cs$ and ${\delta}Ts$ of the C-doped $MgB_2$ were 36.5 K and 2.5 K, respectively. Unlike the m-T characteristics, there existed the difference among the M-H curves of the test samples, which might be caused by the microstructure variation. In spite of the slight $T_c$ decrease, the C doping was effective in enhancing the $J_c$ at 5 K.

A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment (전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구)

  • Park, Gwang-Seo;Kim, Gi-Chae;Kim, Lee-Guk;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.