• Title/Summary/Keyword: Magnetic device

Search Result 934, Processing Time 0.031 seconds

PROTOTYPE AUTOMATIC SYSTEM FOR CONSTRUCTING 3D INTERIOR AND EXTERIOR IMAGE OF BIOLOGICAL OBJECTS

  • Park, T. H.;H. Hwang;Kim, C. S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.318-324
    • /
    • 2000
  • Ultrasonic and magnetic resonance imaging systems are used to visualize the interior states of biological objects. These nondestructive methods have many advantages but too much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct some biological objects to get the interior and exterior information, constructing 3D image from the series of the sliced sectional images gives more useful information with relatively low cost. In this paper, PC based automatic 3D model generator was developed. The system was composed of three modules. One is the object handling and image acquisition module, which feeds and slices objects sequentially and maintains the paraffin cool to be in solid state and captures the sectional image consecutively. The second is the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last is the image processing and visualization module, which processes a series of acquired sectional images and generates 3D graphic model. The handling module was composed of the gripper, which grasps and feeds the object and the cutting device, which cuts the object by moving cutting edge forward and backward. Sliced sectional images were acquired and saved in the form of bitmap file. The 3D model was generated to obtain the volumetric information using these 2D sectional image files after being segmented from the background paraffin. Once 3-D model was constructed on the computer, user could manipulate it with various transformation methods such as translation, rotation, scaling including arbitrary sectional view.

  • PDF

Development of Automatic System for 3D Visualization of Biological Objects

  • Choi, Tae Hyun;Hwnag, Heon;Kim, Chul Su
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.2
    • /
    • pp.95-99
    • /
    • 2000
  • Nondestructive methods such as ultrasonic and magnetic resonance imaging systems have many advantages but still much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct some biological objects to get interior and exterior informations, constructing 3D image form a series of slices sectional images gives more useful information with relatively low cost. In this paper, a PC based automatic 3D model generator was developed. The system was composed of three modules. The first module was the object handling and image acquisition module, which fed and sliced the object sequentially and maintains the paraffine cool to be in solid state and captures the sectional image consecutively. The second one was the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last was the image processing and visualization module, which processed a series of acquired sectional images and generated 3D volumetric model. Handling module was composed of the gripper, which grasped and fed the object and the cutting device, which cuts the object by moving cutting edge forward and backward. sliced sectional images were acquired and saved in a form of bitmap file. 2D sectional image files were segmented from the background paraffine and utilized to generate the 3D model. Once 3-D model was constructed on the computer, user could manipulated it with various transformation methods such as translation, rotation, scaling including arbitrary sectional view.

  • PDF

저온 증착 Nano-Crystalline TCO

  • Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.6-6
    • /
    • 2010
  • Indium Tin Oxide (ITO)를 포함한 Transparent Conduction Oxide (TCO)는 LCD, OLED와 같은 Display, 그리고 Solar Cell 등 광신호와 전기신호간 변환이 필요한 모든 Device에 반드시 필요한 핵심 물질로, 특히 고특성 Display의 투명전극에서 요청되는 95% 이상의 투과도와 $15\;{\Omega}/{\square}$ 이하의 면저항 특성을 동시에 만족할 수 있는 기술은 현재까지 Plasma Sputtering 공정으로 $160^{\circ}C$ 이상에서 증착된 ITO 박막이 유일하다. 그러나, 최근 차세대 기술로서 Plastic Film을 기반으로 하는 Flexible Display 및 Flexible Solar Cell 구현에 대한 요구가 급증하면서, Plastic Film 기판위에 Plasma Damage이 없이 상온에 가까운 저온 ($100^{\circ}C$ 이하)에서 특성이 우수한 ITO 투명전극을 형성 할 수 있는 기술의 확보가 중요한 현안이 되고 있다. 지난 10년 동안 $100^{\circ}C$이하 저온에서 고특성의 ITO 또는 TCO 박막을 얻기위한 다양한 연구와 구체적인 공정이 활발히 연구되어 왔으나, ITO의 결정화 온도 (통상 $150{\sim}180^{\circ}C$)이하에서 증착된 ITO박막은 비정질 상태의 물성적 특성을 보여 원하는 전기적, 광학적 특성확보가 어려웠다. 본 논문에선 기본적으로 절연체 특성을 가져야 하는 산화물인 TCO가 반도체 또는 도체의 물리적 특성을 보여주는 기본원리의 고찰을 토대로, 재료학적 특성상 Crystalline 구조를 보여야 하는 ITO (Complex Cubic Bixbyte Structure)가 Plasma Sputtering 공정으로 저온에서 증착될 때 비정질 구조를 갖게 되는 원인을 규명하고, 이를 바탕으로 저온에서 증착된 ITO가 Crystalline 구조를 유지 할 수 있게 하고, Stress Control에 유리한 Nano-Crystalline 박막을 형성하면서 Crystallinity를 임의로 조절 할 수 있는 새로운 기술인 Magnetic Field Shielding Sputtering (MFSS) 공정과 최근 성과를 소개한다. 한편, 또 다른 새로운 저온 TCO 박막형성 기술로서, 유기반도체와 같은 Process Damage에 매우 취약한 유기물 위에 Plasma Damage 없이 TCO 박막을 직접 형성할 수 있는 Neutral Beam Assisted Sputtering (NBAS) 기술의 원리를 설명하고, 본 공정을 적용한 Top Emission OLED 소자의 결과를 소개한다. 또한, 고온공정이 수반되는 Solar Cell용 투명전극의 경우, 통상의 TCO박막이 고온공정을 거치면서 전기적 특성이 열화되는 원인을 규명하고, 이에 대한 근본적 해결 방법으로 ITO 박막의 Dopant인 Tin (Sn) 원자의 활성화를 증가시킨 Inductively Coupled Plasma Assisted DC Magnetron Sputtering (ICPDMS)의 원리와 박막의 물성적 특성과 내열 특성을 소개한다.

  • PDF

Programmatic Sequence for the Automatic Adjustment of Double Relaxation Oscillation SQUID Sensors

  • Kim, Kiwoong;Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kang, Chan-Seok;Kim, In-Seon;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.42-47
    • /
    • 2002
  • Measuring magnetic fields with a SQUID sensor always requires preliminary adjustments such as optimum bas current determination and flux-locking point search. A conventional magnetoencephalography (MEG) system consists of several dozens of sensors and we should condition each sensor one by one for an experiment. This timeconsuming job is not only cumbersome but also impractical for the common use in hospital. We had developed a serial port communication protocol between SQUID sensor controllers and a personal computer in order to control the sensors. However, theserial-bus-based control is too slow for adjusting all the sensors with a sufficient accuracy in a reasonable time. In this work, we introduce programmatic control sequence that saves the number of the control pulse arrays. The sequence separates into two stages. The first stage is a function for searching flux-locking points of the sensors and the other stage is for determining the optimum bias current that operates a sensor in a minimum noise level Generally, the optimum bias current for a SQUID sensor depends on the manufactured structure, so that it will not easily change about. Therefore, we can reduce the time for the optimum bias current determination by using the saved values that have been measured once by the second stage sequence. Applying the first stage sequence to a practical use, it has taken about 2-3 minutes to perform the flux-locking for our 37-channel SQUID magnetometer system.

  • PDF

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

Design of ESPAR Antenna using Patch Antenna and Performance Analysis of MIMO Communications (패치안테나를 이용한 ESPAR 안테나 설계와 MIMO 통신 성능 분석)

  • Keum, Hong-Sik;An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.10
    • /
    • pp.579-584
    • /
    • 2014
  • In this paper, we propose beamsapce MIMO(mulitple input multiple output) system using patch ESPAR(Electronically Steerable Parasitic Array Radiator) antenna. When using conventional monopole ESPAR antenna, we have advantages cost of hardware and power consumption of RF cirsuit because of single RF chian. But it is difficult to apply to small portable mobile device. Therefore we design patch ESPAR antenna in order to reducing volume and analyze performance of BS MIMO system that is able to MIMO communication with single RF chain. In This paper, we confirm beam pattern of designed patch ESPAR antenna is steered as ${\pm}15^{\circ}$ elevation angle. Furthermore, we design BS MIMO system using this ESPAR antenna and confirm BER performance of this system.

Integrated Optical Waveguide Isolator Based Multimode Interference Using Magnetooptic Characteristics (자기 광학적 특성을 이용한 다중 모드 간섭에 기반한 집적 광 도파로 아이솔레이터)

  • Yang, Jeong-Su
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.148-152
    • /
    • 2005
  • A novel interferometric isolator has been proposed and designed to fabrticate waveguide magnetooptic isolator operating at a wavelength of $1.55{\cal}um$. The device consists of MMI (multimode interference) couplers and has a magnetooptic guiding layer with different layer structure in arms of the inteferometer. The layer structures in the arms of inteferometer are $HfO_2/CeY_2Fe_5O_{12}/NOG$ and $SiO_2/CeY_2Fe_5O_{12}/NOG$, respectively. This configuration give rise to different nonreciprocal phase shift. In consequence, the isolator operates under a unidirectional magnetic field. The optimized structure of the isolator was determined by a 3D beam propagation method.

Trial Maunfacture of Planar Type Micro Inductors (평면형 마이크로인덕터의 시작에 관한 연구)

  • 김종오;강희우;김영학;김동연;오호영
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.6
    • /
    • pp.367-374
    • /
    • 1996
  • The developmement of electronic machine industries requires miniature of size as well as increasement of driving frequency in electronic parts, recently. To realize micro-struture of magnetic devices, in this study, we fabricated thin film inductors by using thin film manufacturing techniques such as photolithography and wet etching process, and these devices are measured at high frequency range of 1 MHz~1 GHz. The results are as follows. The accurate measuring technique by using network analyzer system having microstrip line was established. The manufactured inductors are fabricated with several ten micrometers by means of wet etching process known as easier and more economic than dry etching process. VVhen the device size of two types (spiral, meander) is the same, inductance value L and quality factor Q of spiral type devices are larger than those of meander type, but driving frequency of spiral type is lower than that of meander type due to increasement of inductance L. It is necessary to decrease resistance value R by increasing cross section of the conductor film coil. Thus high frequency measuring method would be a very useful for another measuring fields of the range over several hundreds MHz.

  • PDF

Evidence of Spin Reorientation by Mössbauer Analysis

  • Myoung, Bo Ra;Kim, Sam Jin;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.126-129
    • /
    • 2014
  • We report the crystallographic and magnetic properties of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ by means of X-ray diffractometer (XRD), a superconducting quantum interference device (SQUID) magnetometer, and a M$\ddot{o}$ssbauer spectroscopy. In particular, $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was studied by M$\ddot{o}$ssbauer analysis for evidence of spin reorientation. The chalcogenide material $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was fabricated by a direct reaction method. XRD analysis confirmed that $Ni_{0.3}Fe_{0.7}Ga_2S_4$ has a 2-dimension (2-D) triangular lattice structure, with space group P-3m1. The M$\ddot{o}$ssbauer spectra of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ at spectra at various temperatures from 4.2 to 300 K showed that the spectrum at 4.2 K has a severely distorted 8-line shape, as spin liquid. Electric quadrupole splitting, $E_Q$ has anomalous two-points of temperature dependence of $E_Q$ curve as freezing temperature, $T_f=11K$, and N$\acute{e}$el temperature, $T_N=26K$. This suggests that there appears to be a slowly-fluctuating "spin gel" state between $T_f$ and $T_N$, caused by non-paramagnetic spin state below $T_N$. This comes from charge re-distribution due to spin-orientation above $T_f$, and $T_N$, due to the changing $E_Q$ at various temperatures. Isomer shift value ($0.7mm/s{\leq}{\delta}{\leq}0.9mm/s$) shows that the charge states are ferrous ($Fe^{2+}$), for all temperature range. The Debye temperature for the octahedral site was found to be ${\Theta}_D=260K$.

Shape memory alloy (SMA)-based head and neck immobilizer for radiotherapy

  • Lee, Hyun-Taek;Kim, Sung-In;Park, Jong Min;Kim, Ho-Jin;Song, Dae-Seob;Kim, Hyung-Il;Wu, Hong-Gyun;Ahn, Sung-Hoon
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.3
    • /
    • pp.176-182
    • /
    • 2015
  • Head-and-neck cancer is often treated with intensive irradiation focused on the tumor, while delivering the minimum amount of irradiation to normal cells. Since a course of radiotherapy can take 5-6 weeks or more, the repeatability of the patient posture and the fastening method during treatment are important determinants of the success of radiotherapy. Many devices have been developed to minimize positional discrepancies, but all of the commercial devices used in clinical practice are operated manually and require customized fixtures for each patient. This is inefficient and the performance of the fixture device depends on the operator's skill. Therefore, this study developed an automated head-and-neck immobilizer that can be used during radiotherapy and evaluated the positioning reproducibility in a phantom experiment. To eliminate interference caused by the magnetic field from computed tomography hardware, Ni-Ti shape-memory alloy wires were used as the actuating elements of the fixtures. The resulting positional discrepancy was less than 5 mm for all positions, which is acceptable for radiotherapy.