• Title/Summary/Keyword: Magnetic array

Search Result 285, Processing Time 0.028 seconds

A Study on Dip-Pen Nanolithography Process to fabricate Two-dimensional Photonic Crystal for Planar-type Optical Biosensor (평판형 광-바이오센서용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim Jun-Hyong;Lee Jong-Il;Lee Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.267-272
    • /
    • 2006
  • Optical waveguide based on symmetric and asymmetric Mach-Zehnder interferometer(MZI) type was designed, fabricated and measured the optical characteristics for the application of biosensor. The wavelength of the input optical signal for the device was 1550 nm. And the difference of refractive index was $0.45\;{\Delta}\%$ between core and cladding of the device. The TM(Transverse Magnetic) mode optical properties of the biosensor were analyzed with the refractive index variation of gold thin film deposited for overclad. Nowadays, nano-photonic crystal structures have been paied much attention for its high optical sensitivity. There is a technique to realize the structure, which is called Dip-Pen Nanolithography(DPN) process. The process requires a nano-scale process patterning resolution and high reliability. In this paper, two dimensional nano-photonic crystal array on the surface was proposed for improving the sensitivity of optical biosensor. And the Dip-Pen Nanolithogrphy process was investigated to realize it.

Sensor Calibration of a Helmet MEG System (헬멧형 뇌자도 장치의 센서 교정)

  • Kwon, H.;Kim, K.;Yu, K.K.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.

Development of rotary-magnet type magnetron source for large area sputtering on flexible substrate (대면적 플랙시블 기판용 회전자석형 마그네트론 소스 개발)

  • Cho, Chan Seob;Yun, Sung Ho;Kim, Bong Hwan;Kim, Kwang Tae;Jung, Young Chul;Lee, Jong Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • In this study, a high performance rotary magnet type magnetron source for roll-to-roll sputter system has been developed. We analyzed the density of magnetic field as a function of size variation of the magnet which are in the center and edge of the target. The target efficiency showed the best result when the width of center magnet, the width of edge magnet, the angle of edge magnet, and the rotation angle of Yoke are 20mm, 10mm, $56^{\circ}$, and $16^{\circ}$, respectively. On the basis of the results of magnet array, Roll-to Roll magnetron source was fabricated and tested. The uniformity of the film thickness and that of the sheet resistance was ${\pm}1.62%$ and ${\pm}4.13%$, and the resistivity was $2.79{\times}10^{-3}W{\cdot}cm$.

OH MASERS TOWARDS THE W49A STAR-FORMING REGION WITH MERLIN AND e-MERLN OBSERVATIONS

  • ASANOK, KITIYANEE;ETOKA, SANDRA;GRAY, MALCOLM D.;RICHARDS, ANITA M.S.;KRAMER, BUSABA H.;GASIPRONG, NIPON
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.125-127
    • /
    • 2015
  • We present preliminary results from OH ground state phase referenced observations carried out with the Multi Element Radio Linked Interferometer Network (MERLIN) and e-MERLIN towards the massive star forming region W49A. There are three active SFRs within this complex: W49 North (W49 N), W49 South (W49 S) and W49 South West (W49 SW). The first epoch of observations was obtained in 2005 with MERLIN while the second epoch was obtained in 2013 with the e-MERLIN upgraded system. In this paper, we present 1665 and 1720 MHz maser emission towards W49 S and W49 SW. Overall, both epochs show good agreement with the previous observations of Argon et al. (2000) carried out with the Very Large Array (VLA). The better sensitivity and wider velocity coverage of the MERLIN/e-MERLIN observations allowed us to discover a new 1720 MHz OH maser site in W49 S.

Characteristic Analysis of Linear Permanent Magnet Synchronous Motor according to steel and back iron. (철심의 유/무에 따른 직선형 영구 자석 동기 모터의 특성 해석)

  • Jang, Seok-Myeong;You, Dae-Joon;Lee, Sung-Ho;Chioi, Jang-Young;Jang, Won-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1054-1056
    • /
    • 2003
  • The slotless Permanent-Magnet Linear Synchronous Motors (PMLSM) have been developed for factory automation, transportation applications, wafer steppers, conveyance system, and so on. The current analysis and design are treated in air-cored PMLSM. This paper presents a design and analysis solutions for the general class of iron-cored Permanent magnet Linear Synchronous motor (PMLSM). In our design and analysis, rotor consisting of permanent magnets and slot less iron-cored coil stator are treated in a uniform way via vector potiential. For one such motor structure we give analytical formulas for its magnetic field, opitimal permanent magnet and winding coil thickness, trust force. We also provide comparisons of three types in Halbach, vertical, and horizontal magnet array.

  • PDF

Brain Mapping: From Anatomics to Informatics

  • Sun, Woong
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.184-187
    • /
    • 2016
  • Neuronal connectivity determines brain function. Therefore, understanding the full map of brain connectivity with functional annotations is one of the most desirable but challenging tasks in science. Current methods to achieve this goal are limited by the resolution of imaging tools and the field of view. Macroscale imaging tools (e.g., magnetic resonance imaging, diffusion tensor images, and positron emission tomography) are suitable for large-volume analysis, and the resolution of these methodologies is being improved by developing hardware and software systems. Microscale tools (e.g., serial electron microscopy and array tomography), on the other hand, are evolving to efficiently stack small volumes to expand the dimension of analysis. The advent of mesoscale tools (e.g., tissue clearing and single plane ilumination microscopy super-resolution imaging) has greatly contributed to filling in the gaps between macroscale and microscale data. To achieve anatomical maps with gene expression and neural connection tags as multimodal information hubs, much work on information analysis and processing is yet required. Once images are obtained, digitized, and cumulated, these large amounts of information should be analyzed with information processing tools. With this in mind, post-imaging processing with the aid of many advanced information processing tools (e.g., artificial intelligence-based image processing) is set to explode in the near future, and with that, anatomic problems will be transformed into informatics problems.

Identification of New Urinary Metabolites of Byakangelicin, a Component of Angelicae dahuricae Radix, in Rats

  • Kwon, Oh-Seung;Song, Yun-Seon;Shin, Kuk-Hyun;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • v.26 no.8
    • /
    • pp.606-611
    • /
    • 2003
  • Byakangelicin, 9-(2,3-dihydroxy-2-methylbutoxy)-4-methoxy-7H- furo[3,2-g][l]benzopyran-7-one (BKG), a component of Angelicae dahuricae Radix, is considered to be an inhibitor of aldose reductase for the treatment of diabetic cataract. An analytical method for the isolation of BKG developed by high-performance liquid chromatography has been reported. No literature on the metabolism of BKG, however, has been found. With the purpose of identifying new metabolites of BKG, BKG (100 mg/kg) was orally administered to Sprague-Dawley rats via a gavage. Using a metabolic cage, urine was collected for 24 h, and the urine samples were extracted by liquid-liquid extraction. For structural identification of new urinary metabolites of BKG, various instrumental analyses were conducted by gas-chromatography/mass spectrometry, high-performance liquid chromatography/diode array detector, liquid chromatography/mass spectroscopy with thermospray interface and $^1H$ nuclear magnetic resonance spectroscopy. Two metabolites produced from the Ο-demethylation or Ο-dealkylation of BKG were newly identified, and another new but unknown metabolite was assumed to be the hydroxylated form of BKG. These results indicate that the major metabolic products of BKG are formed by Ο-demethylation or Ο-dealkylation of BKG side chains.

Interferometric Monitoring of Gamma-Ray Bright AGNs: 4C +28.07 and Its Synchrotron Self-Absorption Spectrum

  • Myoung-Seok Nam;Sang-Sung Lee;Whee Yeon Cheong
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.231-252
    • /
    • 2023
  • We present the analysis results of the simultaneous multifrequency observations of the blazar 4C +28.07. The observations were conducted by the Interferometric Monitoring of Gamma-ray Bright Active Galactic Nuclei (iMOGABA) program, which is a key science program of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN). Observations of the iMOGABA program for 4C +28.07 were conducted from 16 January 2013 (MJD 56308) to 13 March 2020 (MJD 58921). We also used γ-ray data from the Fermi Large Array Telescope (Fermi-LAT) Light Curve Repository, covering the energy range from 100 MeV to 100 GeV. We divided the iMOGABA data and the Fermi-LAT data into five periods from 0 to 4, according to the prosody of the 22 GHz data and the presence or absence of the data. In order to investigate the characteristics of each period, the light curves were plotted and compared. However, a peak that formed a hill was observed earlier than the period of a strong γ-ray flare at 43-86 GHz in period 3 (MJD 57400-58100). Therefore, we assumed that the minimum total CLEANed flux density for each frequency was quiescent flux (Sq) in which the core of 4C +28.07 emitted the minimum, with the variable flux (Svar) obtained by subtracting Sq from the values of the total CLEANed flux density. We then compared the variability of the spectral indices (α) between adjacent frequencies through a spectral analysis. Most notably, α22-43 showed optically thick spectra in the absence of a strong γ-ray flare, and when the flare appeared, α22-43 became optically thinner. In order to find out the characteristics of the magnetic field in the variable region, the magnetic field strength in the synchrotron self-absorption (BSSA) and the equipartition magnetic field strength (Beq) were obtained. We found that BSSA is largely consistent with Beq within the uncertainty, implying that the SSA region in the source is not significantly deviated from the equipartition condition in the γ-ray quiescent periods.

Effective Geophysical Methods in Detecting Subsurface Caves: On the Case of Manjang Cave, Cheju Island (지하 동굴 탐지에 효율적인 지구물리탐사기법 연구: 제주도 만장굴을 대상으로)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Lee, Gyu-Ho;Rim, Hyoung-Rea;Oh, Seok-Hoon
    • Journal of the Korean earth science society
    • /
    • v.21 no.4
    • /
    • pp.408-422
    • /
    • 2000
  • Multiple geophysical methods were applied over the Manjang cave area in Cheju Island to compare and contrast the effectiveness of each method for exploration of underground cavities. The used methods are gravity, magnetic, electrical resistivity and GPR(Ground Pentrating Radar) survey, of which instruments are portable and operations are relatively economical. We have chosen seven survey lines and applied appropriate multiple surveys depending on the field conditions. In the case of magnetic method. two-dimensional grid-type surveys were carried out to cover the survey area. The geophysical survey results reveal the characteristic responses of each method relatively well. Among the applied methods, the electric resistivity methods appeared to be the most effective ones in detecting the Manjang Cave and surrounding miscellaneous cavities. Especially, on the inverted resistivity section obtained from the dipole-dipole array data, the two-dimensional distribution of high resistivity cavities are revealed well. The gravity and magnetic data are contaminated easily by various noises and do not show the definitive responses enough to locate and delineate the Manjang cave. But they provide useful information in verifying the dipole-dipole resistivity survey results. The grid-type 2-D magnetic survey data show the trend of cave development well, and it may be used as a reconnaissance regional survey for determining survey lines for further detailed explorations. The GPR data show very sensitive response to the various shallow volcanic structures such as thin spaces between lava flows and small cavities, so we cannot identify the response of the main cave. Although each geophysical method provides its own useful information, the integrated interpretation of multiple survey data is most effective for investigation of the underground caves.

  • PDF

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF