• Title/Summary/Keyword: Magnetic array

검색결과 286건 처리시간 0.024초

다중회귀분석을 이용한 BK7 글래스 MR Polishing 공정의 재료 제거 조건 분석 (Analysis of Material Removal Rate of Glass in MR Polishing Using Multiple Regression Design)

  • 김동우;이정원;조명우;신영재
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.184-190
    • /
    • 2010
  • Recently, the polishing process using magnetorheological fluids(MR fluids) has been focused as a new ultra-precision polishing technology for micro and optical parts such as aspheric lenses, etc. This method uses MR fluid as a polishing media which contains required micro abrasives. In the MR polishing process, the surface roughness and material removal rate of a workpiece are affected by the process parameters, such as the properties of used nonmagnetic abrasives(particle material, size, aspect ratio and density, etc.), rotating wheel speed, imposed magnetic flux density and feed rate, etc. The objective of this research is to predict MRR according to the polishing conditions based on the multiple regression analysis. Three polishing parameters such as wheel speed, feed rates and current value were optimized. For experimental works, an orthogonal array L27(313) was used based on DOE(Design of Experiments), and ANOVA(Analysis of Variance) was carried out. Finally, it was possible to recognize that the sequence of the factors affecting MRR correspond to feed rate, current and wheel speed, and to determine a combination of optimal polishing conditions.

평판형 광-바이오센서용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구 (A Study on Dip-Pen Nanolithography Process to fabricate Two-dimensional Photonic Crystal for Planar-type Optical Biosensor)

  • 김준형;이종일;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.267-272
    • /
    • 2006
  • Optical waveguide based on symmetric and asymmetric Mach-Zehnder interferometer(MZI) type was designed, fabricated and measured the optical characteristics for the application of biosensor. The wavelength of the input optical signal for the device was 1550 nm. And the difference of refractive index was $0.45\;{\Delta}\%$ between core and cladding of the device. The TM(Transverse Magnetic) mode optical properties of the biosensor were analyzed with the refractive index variation of gold thin film deposited for overclad. Nowadays, nano-photonic crystal structures have been paied much attention for its high optical sensitivity. There is a technique to realize the structure, which is called Dip-Pen Nanolithography(DPN) process. The process requires a nano-scale process patterning resolution and high reliability. In this paper, two dimensional nano-photonic crystal array on the surface was proposed for improving the sensitivity of optical biosensor. And the Dip-Pen Nanolithogrphy process was investigated to realize it.

헬멧형 뇌자도 장치의 센서 교정 (Sensor Calibration of a Helmet MEG System)

  • 권혁찬;김기웅;유권규;김진목;이용호
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.

대면적 플랙시블 기판용 회전자석형 마그네트론 소스 개발 (Development of rotary-magnet type magnetron source for large area sputtering on flexible substrate)

  • 조찬섭;윤성호;김봉환;김광태;정영철;이종현
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.1-6
    • /
    • 2012
  • In this study, a high performance rotary magnet type magnetron source for roll-to-roll sputter system has been developed. We analyzed the density of magnetic field as a function of size variation of the magnet which are in the center and edge of the target. The target efficiency showed the best result when the width of center magnet, the width of edge magnet, the angle of edge magnet, and the rotation angle of Yoke are 20mm, 10mm, $56^{\circ}$, and $16^{\circ}$, respectively. On the basis of the results of magnet array, Roll-to Roll magnetron source was fabricated and tested. The uniformity of the film thickness and that of the sheet resistance was ${\pm}1.62%$ and ${\pm}4.13%$, and the resistivity was $2.79{\times}10^{-3}W{\cdot}cm$.

OH MASERS TOWARDS THE W49A STAR-FORMING REGION WITH MERLIN AND e-MERLN OBSERVATIONS

  • ASANOK, KITIYANEE;ETOKA, SANDRA;GRAY, MALCOLM D.;RICHARDS, ANITA M.S.;KRAMER, BUSABA H.;GASIPRONG, NIPON
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.125-127
    • /
    • 2015
  • We present preliminary results from OH ground state phase referenced observations carried out with the Multi Element Radio Linked Interferometer Network (MERLIN) and e-MERLIN towards the massive star forming region W49A. There are three active SFRs within this complex: W49 North (W49 N), W49 South (W49 S) and W49 South West (W49 SW). The first epoch of observations was obtained in 2005 with MERLIN while the second epoch was obtained in 2013 with the e-MERLIN upgraded system. In this paper, we present 1665 and 1720 MHz maser emission towards W49 S and W49 SW. Overall, both epochs show good agreement with the previous observations of Argon et al. (2000) carried out with the Very Large Array (VLA). The better sensitivity and wider velocity coverage of the MERLIN/e-MERLIN observations allowed us to discover a new 1720 MHz OH maser site in W49 S.

철심의 유/무에 따른 직선형 영구 자석 동기 모터의 특성 해석 (Characteristic Analysis of Linear Permanent Magnet Synchronous Motor according to steel and back iron.)

  • 장석명;유대준;이성호;최장영;장원범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1054-1056
    • /
    • 2003
  • The slotless Permanent-Magnet Linear Synchronous Motors (PMLSM) have been developed for factory automation, transportation applications, wafer steppers, conveyance system, and so on. The current analysis and design are treated in air-cored PMLSM. This paper presents a design and analysis solutions for the general class of iron-cored Permanent magnet Linear Synchronous motor (PMLSM). In our design and analysis, rotor consisting of permanent magnets and slot less iron-cored coil stator are treated in a uniform way via vector potiential. For one such motor structure we give analytical formulas for its magnetic field, opitimal permanent magnet and winding coil thickness, trust force. We also provide comparisons of three types in Halbach, vertical, and horizontal magnet array.

  • PDF

Brain Mapping: From Anatomics to Informatics

  • Sun, Woong
    • Applied Microscopy
    • /
    • 제46권4호
    • /
    • pp.184-187
    • /
    • 2016
  • Neuronal connectivity determines brain function. Therefore, understanding the full map of brain connectivity with functional annotations is one of the most desirable but challenging tasks in science. Current methods to achieve this goal are limited by the resolution of imaging tools and the field of view. Macroscale imaging tools (e.g., magnetic resonance imaging, diffusion tensor images, and positron emission tomography) are suitable for large-volume analysis, and the resolution of these methodologies is being improved by developing hardware and software systems. Microscale tools (e.g., serial electron microscopy and array tomography), on the other hand, are evolving to efficiently stack small volumes to expand the dimension of analysis. The advent of mesoscale tools (e.g., tissue clearing and single plane ilumination microscopy super-resolution imaging) has greatly contributed to filling in the gaps between macroscale and microscale data. To achieve anatomical maps with gene expression and neural connection tags as multimodal information hubs, much work on information analysis and processing is yet required. Once images are obtained, digitized, and cumulated, these large amounts of information should be analyzed with information processing tools. With this in mind, post-imaging processing with the aid of many advanced information processing tools (e.g., artificial intelligence-based image processing) is set to explode in the near future, and with that, anatomic problems will be transformed into informatics problems.

Identification of New Urinary Metabolites of Byakangelicin, a Component of Angelicae dahuricae Radix, in Rats

  • Kwon, Oh-Seung;Song, Yun-Seon;Shin, Kuk-Hyun;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • 제26권8호
    • /
    • pp.606-611
    • /
    • 2003
  • Byakangelicin, 9-(2,3-dihydroxy-2-methylbutoxy)-4-methoxy-7H- furo[3,2-g][l]benzopyran-7-one (BKG), a component of Angelicae dahuricae Radix, is considered to be an inhibitor of aldose reductase for the treatment of diabetic cataract. An analytical method for the isolation of BKG developed by high-performance liquid chromatography has been reported. No literature on the metabolism of BKG, however, has been found. With the purpose of identifying new metabolites of BKG, BKG (100 mg/kg) was orally administered to Sprague-Dawley rats via a gavage. Using a metabolic cage, urine was collected for 24 h, and the urine samples were extracted by liquid-liquid extraction. For structural identification of new urinary metabolites of BKG, various instrumental analyses were conducted by gas-chromatography/mass spectrometry, high-performance liquid chromatography/diode array detector, liquid chromatography/mass spectroscopy with thermospray interface and $^1H$ nuclear magnetic resonance spectroscopy. Two metabolites produced from the Ο-demethylation or Ο-dealkylation of BKG were newly identified, and another new but unknown metabolite was assumed to be the hydroxylated form of BKG. These results indicate that the major metabolic products of BKG are formed by Ο-demethylation or Ο-dealkylation of BKG side chains.

Interferometric Monitoring of Gamma-Ray Bright AGNs: 4C +28.07 and Its Synchrotron Self-Absorption Spectrum

  • Myoung-Seok Nam;Sang-Sung Lee;Whee Yeon Cheong
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.231-252
    • /
    • 2023
  • We present the analysis results of the simultaneous multifrequency observations of the blazar 4C +28.07. The observations were conducted by the Interferometric Monitoring of Gamma-ray Bright Active Galactic Nuclei (iMOGABA) program, which is a key science program of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN). Observations of the iMOGABA program for 4C +28.07 were conducted from 16 January 2013 (MJD 56308) to 13 March 2020 (MJD 58921). We also used γ-ray data from the Fermi Large Array Telescope (Fermi-LAT) Light Curve Repository, covering the energy range from 100 MeV to 100 GeV. We divided the iMOGABA data and the Fermi-LAT data into five periods from 0 to 4, according to the prosody of the 22 GHz data and the presence or absence of the data. In order to investigate the characteristics of each period, the light curves were plotted and compared. However, a peak that formed a hill was observed earlier than the period of a strong γ-ray flare at 43-86 GHz in period 3 (MJD 57400-58100). Therefore, we assumed that the minimum total CLEANed flux density for each frequency was quiescent flux (Sq) in which the core of 4C +28.07 emitted the minimum, with the variable flux (Svar) obtained by subtracting Sq from the values of the total CLEANed flux density. We then compared the variability of the spectral indices (α) between adjacent frequencies through a spectral analysis. Most notably, α22-43 showed optically thick spectra in the absence of a strong γ-ray flare, and when the flare appeared, α22-43 became optically thinner. In order to find out the characteristics of the magnetic field in the variable region, the magnetic field strength in the synchrotron self-absorption (BSSA) and the equipartition magnetic field strength (Beq) were obtained. We found that BSSA is largely consistent with Beq within the uncertainty, implying that the SSA region in the source is not significantly deviated from the equipartition condition in the γ-ray quiescent periods.

지하 동굴 탐지에 효율적인 지구물리탐사기법 연구: 제주도 만장굴을 대상으로 (Effective Geophysical Methods in Detecting Subsurface Caves: On the Case of Manjang Cave, Cheju Island)

  • 권병두;이희순;이규호;임형래;오석훈
    • 한국지구과학회지
    • /
    • 제21권4호
    • /
    • pp.408-422
    • /
    • 2000
  • 지하의 공동탐사에 효과적인 지구물리탐사 기법에 대해서 연구하기 위하여 제주도 만장굴을 대상으로 복합적인 지구물리탐사를 수행하였다. 이번에 사용한 방법은 탐사장비나 야외작업이 비교적 경제적이면서도 지하 공동에 의한 반응을 잘 보여줄 것으로 기대되는 중력, 자력, 전기 비저항, GPR(지하레이더) 탐사 등이다. 현지의 탐사여건을 고려하여 7개의 측선을 선정하고, 각 측선별로 몇 종류의 탐사를 복합적으로 실시하였다. 자력탐사의 경우는 2차원 격자형탐사도 함께 수행하였다. 각 탐사자료상에는 탐사법에 따른 여러 특징들이 잘 나타나고 있어, 그 효용성을 비교 분석할 수 있었다. 이번에 사용한 방법 중 동굴 탐사에 가장 효과적인 탐사법은 전기비저항탐사로 나타났으며, 쌍극자-쌍극자 배열법은 2차원적인 고비저항대로 나타나는 동굴의 존재를 잘 보여준다. 중력, 자력 탐사의 결과는 화산암 지역에서 나타나는 다양한 잡음의 영향으로 동굴의 위치나 규모를 해석해 내기가 쉽지 않지만, 전기비저항탐사 자료에서 인지되는 동굴의 위치와 규모가 적절한지를 검증하는 데에 효과적으로 이용될 수 있었다. 한편, 2차원 격자형 자력탐사 자료는 동굴의 경향성을 잘 보여주므로, 정밀 탐사측선을 결정하는데 유용하다. GPR탐사 자료에는 천부에 존재하는 미세한 틈새들과 소규모 공동들에 의한 반응이 강하게 나타나 상대적으로 심부에 위치하는 주동굴의 존재를 확인하기는 힘들었다. 이번 연구의 결과는 제한 된 수의 탐사법만을 적용하였기 때문에 어떤 결정적인 결론을 내리기는 어렵지만, 지하 동굴의 경우는 복합적인 탐사를 수행하고 그 자료들을 상호보완적으로 사용함으로써 해석결과의 신뢰도를 높일 수 있는 것으로 나타났다.

  • PDF