• 제목/요약/키워드: Magnetic array

검색결과 285건 처리시간 0.03초

수중 센서 어레이에서 고 신뢰성을 고려한 신호 전송 시스템 설계 (A Design of Signal Transport System with High Reliability in an Underwater Sensor Array)

  • 손동환;정현주
    • 한국군사과학기술학회지
    • /
    • 제7권4호
    • /
    • pp.13-19
    • /
    • 2004
  • A system for detecting underwater target demands a high operational reliability because of the difficulty of maintenance and repair when the system has a few troubles during long operating period. Therefore, in this paper, we have proposed a signal transport system with a high reliability in an underwater sensor array system composed of magnetic and acoustic sensors. In this system, the nodes for signal transport are connected dually each other with single-hop construction and a magnetic sensor is connected to a couple of neighboring nodes. This enables the output signal to transport from a node to the next node and the next but one node. Also, the signal from a magnetic sensor can be transported to two nodes at the same time. Thus, the system with this construction makes possible to transport sensor data to another node which works normally when a transport node or cable have some faults and will operate normally although it happens some problems in a few signal transport nodes and connection cables.

마그네트론 음극의 자석 배열에 따른 방전의 형상 변화 연구 (A Study of Discharge Shape Changes by Magnet Arrangements in a Magnetron Cathode)

  • 지정은;주정훈
    • 한국표면공학회지
    • /
    • 제41권3호
    • /
    • pp.94-101
    • /
    • 2008
  • A new convenient magnet array module is designed to investigate effects of magnetic field array on magnetron discharge characteristics. Magnetic field analysis showed good agreement of measured discharge region by a CCD device which has a high quantum efficiency over visible wavelength range. OES (optical emission spectroscopy) showed major emission peaks are from electronic transitions in 400 nm range and 800 nm range. Effects of driving voltage characteristics were analyzed in a point of electron drift trajectories and ionizing collision frequencies. Pulsed dc with a fast rising and falling time was analyzed to have potential to increase ionization collisions by putting a burst of hot electrons and to raise sheath potential. From measured voltage and current waveform, maximum of -1000 V peak was generated with $-400\;V_{rms}$ conditions. Possibility of a properly designed magnetron cathode was shown to be used as a melting device. Cu was successfully melted with power density of a several tens of $W/cm^2$.

A design study of a 4.7 T 85 mm low temperature superconductor magnet for a nuclear magnetic resonance spectrometer

  • Bae, Ryunjun;Lee, Jung Tae;Park, Jeonghwan;Choi, Kibum;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.24-29
    • /
    • 2022
  • One of the recent proposals with nuclear magnetic resonance (NMR) is a multi-bore NMR which consists of array of magnets which could present possibilities to quickly cope with pandemic virus by multiple inspection of virus samples. Low temperature superconductor (LTS) can be a candidate for mass production of the magnet due to its low price in fabrication as well as operation by applying the helium zero boil-off technology. However, training feature of LTS magnet still hinders the low cost operation due to multiple boil-offs during premature quenches. Thus in this paper, LTS magnet with low mechanical stress is designed targeting the "training-free" LTS magnet for mass production of magnet array for multi-bore NMR. A thorough process of an LTS magnet design is conducted, including the analyses as the followings: electromagnetics, mechanical stress, cryogenics, stability, and protection. The magnet specification was set to 4.7 T in a winding bore of 85 mm, corresponding to the MR frequency of 200 MHz. The stress level is tolerable with respect to the wire yield strength and epoxy crack where mechanical disturbance is less than the minimum quench energy.

Improved Metal Object Detection Circuits for Wireless Charging System of Electric Vehicles

  • Sunhee Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권8호
    • /
    • pp.2209-2221
    • /
    • 2023
  • As the supply of electric vehicles increases, research on wireless charging methods for convenience has been increasing. Because the electric vehicle wireless transmission device is installed on the ground and the electric vehicle battery is installed on the floor of the vehicle, the transmission and reception antennas are approximately 15-30 cm away, and thus strong magnetic fields are exposed during wireless charging. When a metallic foreign object is placed in the magnetic field area, an eddy current is induced to the metallic foreign object, and heat is generated, creating danger of fire and burns. Therefore, this study proposes a method to detect metallic foreign objects in the magnetic field area of a wireless electric vehicle charging system. An active detection-only coil array was used, and an LC resonance circuit was constructed for the frequency of the supply power signal. When a metallic foreign object is inserted into the charging zone, the characteristics of the resonance circuit are broken, and the magnitude and phase of the voltage signal at both ends of the capacitor are changed. It was confirmed that the proposed method has about 1.5 times more change than the method of comparing the voltage magnitude at one node.

자기공명영상촬영을 위한 Phased-Array Quadrature RF 코일 (Phased-Array Quadrature RF Coil for Magnetic Resonance Imaging)

  • 김선경;양윤정;이덕래;안창범;이흥규;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.227-229
    • /
    • 1997
  • A new phased-array quadrature RF coil for one or two RF acquisition channels is developed for spine MR imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by $"\sqrt{2}"$ using two orthogonal RF coils in combination [1]. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of RF coil elements with a reduced size and coverage for each element. Two new schemes are proposed for the new phased-array quadrature RF coil as follows : (1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive- only mode. It has been tested through phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

신호원 국소화를 위한 위치의 최적화 : MNLS (Optimization of sensor location for source localization : Minimum-Norm Least-Square Method)

  • 김유정;한주만;이인범;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.124-126
    • /
    • 2000
  • The Minimum-Norm Least-Square(MNLS) approach based on lead field theory is an useful method to find an unique inverse solution for the measured magnetic field. The lead field depends on head geometry and location of sources and sensors. So, optimization of sensor array location is important issue for MNLS estimation. In this paper, we present an investigation for the optimization of sensor array location in computer simulation.

  • PDF

직교배열표를 이용한 다목적 퍼지제어 알고리즘 개발 및 응용 (Development of Fuzzy Control Algorithm for Multi-Objective Problem using Orthogonal Array and its Applications)

  • 김추호;박성호;이종원;변증남
    • 한국지능시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.368-373
    • /
    • 2000
  • In this paper, a control algorthm suitable for multi-objective control is proposed based on the orthogonal array which is normally used in statics and industrial engineering. And a newly defined Nthcertainty factor is suggested, which can effectively exclude the less confident rule. The Nth-certainty factor is defined by the F-values of the ANOVA(analysis of variance) table. It is shown that the algorithm can be successfully adopted to the design of controller for an active magnetic bearing system.

  • PDF

직교배열표를 이용한 다목적 퍼지제어 알고리즘 개발 및 응용 (Development of Fuzzy Control Algorithm for Multi-Objective Problem using Orthogonal Array and its Applications)

  • 김추호;박성호;이종원;변중남
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 춘계학술대회 학술발표 논문집
    • /
    • pp.63-68
    • /
    • 2000
  • In this paper, a control algorithm suitable for multi-objective control problems is proposed based on the orthogonal array which is normally used in statistics and industrial engineering. And a newly defined Nth-certainty factor is suggested, which can effectively exclude the less confident rules. The Nth-certainty factor is defined by the F-values of the ANOVA(analysis of variance) table. It is shown that the algorithm can be successfully adopted to the design of controller for an active magnetic bearing system.

  • PDF

theta 코일을 이용한 척추용 코일의 개발

  • 이희조;김대홍;서진석;이삼현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.95-95
    • /
    • 2002
  • 목적: 기존의 척추용 코일은 phased array 코일을 주로 많이 사용하여 왔다. Phased array 코일은 여러개의 표면 코일로 구성되어 있어 RE 자기장의 영역이 표면코일과 비슷하다. 그래서, 척추 영상을 얻기 위해서는 다른 부위의 핵 스핀을 포화시키는 불편함이 있다. 기존의 표면 코일보다 RF penetration depth가 적은 theta coil을 이용하여, 척추에 적합한 코일을 개발했다. 대상 및 방법: theta coil을 길게 제작하여 척추에 적합하게 하였다. 코일의 길이는 약 35cm, 폭은 16cm이다. 수신 전용으로 하기 위해서, 다이오드를 이용하여 detune 회로를 포함하였다. 기존의 코일과 비교하기 위해 theta coil과 GE사의 척추용 코일로부터 각각 영상을 획득하였다.

  • PDF

휴대장치용 새로운 자기 스프링 액추에이터의 해석 (Analysis of Novel Magnetic-Spring Actuators for Portable Units)

  • 한인환
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1942-1949
    • /
    • 2004
  • SLA(Scanned Linear Array) is a portable display unit for implementing next-generation virtual realities, utilizes a design that light generated by a line of LEDs is reflected from the rapidly oscillating mirror to generate a raster display. Reaction forces generated by the motions of the mirror and counter-balance mass cancel each other at the device base, reducing vibration. Metal leaf springs have been extensively applied in such portable units. Magnetic springs have been developed and adopted that can replace the metal spring and can avoid many disadvantages of metal springs. We model and analyze the dynamics of the structure with magnetic springs and present the simulation and experimental analysis results, which can be utilized for identifying and eliminating possible problem sources in removing shaking forces and moments, and oscillating the mirror at the required amplitude and frequency. Finally, we present the improved novel magnetic actuator model which can be applied in portable display units.