• Title/Summary/Keyword: Magnetic Tomography

Search Result 864, Processing Time 0.027 seconds

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Recurrence and Metastasis of Lung Cancer Demonstrate Decreased Diffusion on Diffusion-Weighted Magnetic Resonance Imaging

  • Usuda, Katsuo;Sagawa, Motoyasu;Motomo, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6843-6848
    • /
    • 2014
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) is reported to be useful for detecting malignant lesions. The purpose of this study is to clarify characteristics of imaging, detection rate and sensitivity of DWI for recurrence or metastasis of lung cancer. Methods: A total of 36 lung cancer patients with recurrence or metastasis were enrolled in this study. While 16 patients underwent magnetic resonance imaging (MRI), computed tomography (CT) and positron emission tomography-computed tomography (PET-CT), 17 underwent MRI and CT, and 3 underwent MRI and PET-CT. Results: Each recurrence or metastasis showed decreased diffusion, which was easily recognized in DWI. The detection rate for recurrence or metastasis was 100% (36/36) in DWI, 89% (17/19) in PET-CT and 82% (27/33) in CT. Detection rate of DWI was significantly higher than that of CT (p=0.0244) but not significantly higher than that of PET-CT (p=0.22). When the optimal cutoff value of the apparent diffusion coefficient value was set as $1.70{\times}10^{-3}mm^2/sec$, the sensitivity of DWI for diagnosing recurrence or metastasis of lung cancer was 95.6%. Conclusions: DWI is useful for detection of recurrence and metastasis of lung cancer.

CT and MRI Image Fusion Reproducibility and Dose Assessment on Treatment Planning System (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Choi, Jae-Hyock;Park, Cheol-Soo;Seo, Jeong-Min;Cho, Jae-Hwan;Choi, Cheon-Woong
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.191-196
    • /
    • 2014
  • The purpose of this study is to evaluate the reproducibility and usefulness of an image through the fusion of the computed tomography image and the magnetic resonance image by using a self-produced phantom when planning the treatment, and also to compare and analyze the target dose on the acquired image. The size of small hole and the reproducibility of capacity existed in the phantom on the image of the phantom obtained by the computed tomography and the magnetic resonance image of the phantom scanning with different intensity of magnetic field are compared, and the change of dose in the random target is compared and analyzed.

Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

  • Hyeongmin Jin;Hyun Joon An;Eui Kyu Chie;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 2022
  • Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air cavity in magnetic resonance-guided radiotherapy (MRgRT) for patients with pancreatic cancer. Methods: This study included nine patients that previously received MRgRT and their simulation CT and magnetic resonance (MR) images were collected. Air cavities were manually delineated on simulation CT and MR images in the treatment planning system for each patient. The synthetic CT images were generated using the deep learning model trained in a prior study. Two more plans with identical beam parameters were recalculated with ED maps that were either manually overridden by the cavities or derived from the synthetic CT. Dose calculation accuracy was explored in terms of dose-volume histogram parameters and gamma analysis. Results: The D95% averages were 48.80 Gy, 48.50 Gy, and 48.23 Gy for the original, manually assigned, and synthetic CT-based dose distributions, respectively. The greatest deviation was observed for one patient, whose D95% to synthetic CT was 1.84 Gy higher than the original plan. Conclusions: The variation of the air cavity position in the gastrointestinal area affects the treatment dose calculation. Synthetic CT-based ED modification would be a significant option for shortening the time-consuming process and improving MRgRT treatment accuracy.

Congenital Absence of the Bilateral Internal Carotid Arteries: a Case Report

  • Noh, Jihoon;Kang, Hyunkoo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.193-196
    • /
    • 2021
  • Congenital absence of the bilateral internal carotid arteries (ICA) is a very rare occurrence. Recognition of this rare anomaly is important, when considering intracranial endovascular interventions in the event of thromboembolic events with revascularization, transsphenoidal surgery, and the surveillance and detection of associated cerebral aneurysms. We report a case of a 25-year-old man who presented with headache since 2 years ago, and was incidentally discovered to have a congenital bilateral absence of ICAs.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

Study on the analysis of the Magnetic Tomography System using two poles and four poles (2극 및 4극 Magnetic Tomography System의 특성에 관한 연구)

  • Park, Eun-Sik;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.62-65
    • /
    • 2003
  • 본 연구는 탐지대상물체의 형상인식이 가능한 비접촉, 원격 탐지장치의 개발에 관한 것이다. 본 연구에서는 2극 또는 4극의 정자기장을 인가할 때 탐지대상 물체에 의한 자기장의 자계 왜곡을 홀 센서로 감지하여 탐지 대상 물체를 인식하는 원격 감지 시스템을 설계하고 제작하여 특성을 분석한 결과 2극과 4극 시스템 모두 비 투자율의 변화를 감지 할 수 있었고, 특히 탐사물체의 위치 파악에는 2극 시스템이 4극 시스템에 비하여 좋은 특성을 보였다.

  • PDF

Craniosynostosis : Updates in Radiologic Diagnosis

  • Kim, Hyun Jeong;Roh, Hong Gee;Lee, Il Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.219-226
    • /
    • 2016
  • The purpose of this article is to review imaging findings and to discuss the optimal imaging methods for craniosynostosis. The discussion of imaging findings are focused on ultrasonography, plain radiography, magnetic resonance imaging and computed tomography with 3-dimensional reconstruction. We suggest a strategy for imaging work-up for the diagnosis, treatment planning and follow-up to minimize or avoid ionized radiation exposure to children by reviewing the current literature.

Clinical Analysis of Traumatic Pyomyositis in Emergency Patients (응급실로 내원한 외상성 화농성 근염 환자의 분석)

  • Na, Ji Ung;Song, Hyoung Gon
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Purpose: Pyomyositis is a rare disease in temperature climate region. The diagnosis of pyomyositis is often delayed, and pyomyositis is often misdiagnosed in the emergency department. Methods: The medical records of 11 patients who were diagnosed as having traumatic pyomyositis in the emergency department at Samsung Medical Center in Seoul, Korea, between 2000 and 2006 were reviewed. Their clinical features, such as history, symptoms, clinical findings, duration from onset of symptoms to diagnosis, medical history, laboratory data, results of imaging studies and clinical course were collected. Results: The psoas muscles were most commonly involved. Computer tomography and magnetic resonance imaging aided in accurate diagnosis of the infection and of the extent of involvement. Incision, drainage, and antibiotics therapy eradicated the infectioin in all patients Conclusion: Pyomyositis should be a part of the differential diagnosis for patients with traumatic muscle pain. Radiologic evaluation, such as computer tomography and magnetic resonance imaging, must be considered in the diagnosis of traumatic pyomyositis.

Isolated Oculomotor Nerve Palsy Following Minor Head Trauma : Case Illustration and Literature Review

  • Kim, Ealmaan;Chang, Hyukwon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.434-436
    • /
    • 2013
  • Isolated oculomotor nerve palsy (ONP) attributable to mild closed head trauma is a distinct rarity. Its diagnosis places high demands on the radiologist and the clinician. The authors describe this condition in a 36-year-old woman who slipped while walking and struck her face. Initial computed tomography did not reveal any causative cerebral and vascular lesions or orbital and cranial fractures. Enhancement and swelling of the cisternal segment of the oculomotor nerve was seen during the subacute phase on thin-sectioned contrast-enhanced magnetic resonance images. The current case received corticosteroid therapy, and then recovered fully in 13 months after injury. Possible mechanism of ONP from minor head injury is proposed and previous reports in the literature are reviewed.