• Title/Summary/Keyword: Magnetic Shielding

Search Result 206, Processing Time 0.053 seconds

Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors (전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가)

  • Lee, Joo Hong;Kim, Do Sik;Chang, Mu Seong;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.831-837
    • /
    • 2015
  • Many persons and electronic devices are exposed to electromagnetic (EM) waves generated from magnetic resonance imaging (MRI) equipment, EM pulses (EMPs), and many other kinds of EM wave devices. Finger strips are used to provide shielding from these EM waves. Because of the high thermal conductivity of finger strips, they are used in the design of specialized doors that are installed in shielded rooms. In this study, we perform an accelerated life test using the load acceleration stress, which affects the main failure mode of finger strips. We predict the life of the finger strip under normal usage conditions based on the results of the accelerated life test. We compare the results with those predicted from the life test under normal usage conditions to evaluate the validity of accelerated life testing.

A Study on a Shielding Effect of the Messenger Wires in Distribution Lines (배전선로에서의 조가선 차폐 효과 연구)

  • Kim, In-Soo;Han, Woong;Yeo, Sang-Min;Kim, Chul-Hwan;Weon, Bong-Ju;Lim, Yong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Electromagnetic Interference Shielding of Carbon Fibers-Reinforced Composites (탄소섬유강화 복합재료의 전자파 차폐특성)

  • 심환보;서민강;박수진
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.860-868
    • /
    • 2000
  • In this work, the electro-magnetic interference (EMI) characteristics of PAN-based carbon fibers-reinforced composites are investigated with difference to manufactural parameters, i.e., fiber grade, fiber orientation angle, and laminating method. As a result, EMI shielding effectiveness (SE) of the composites greatly depends on a fiber orientation in composite angle. Especially, the fiber grade affects SE of composites in case of orientation angle of 0$^{\circ}$. Then the SE become greater as the change of electric character according to the arrangement directions, i.e., electrical anisotropy in the same constituent materials. This is due to the skin effect which is represented in the surface of electro-magnetic wave in high-frequency range. In all cases according to lamination methods, the composites represents SE of 83~98% over. Whereas, in symmetric and unsymmetric laminate structures, the SE decreases slightly as the laminate angles of composites increases. On the contrary. the repeating laminates structure shows the opposite tendency. Especially, 90$^{\circ}$ repeating laminate structure shows the SE more than 90% over the measuring frequency.

  • PDF

1-Dimensional simulation of nonlinear magnetic diffusion in high-Tc superconductor

  • Heo, K.S.;Seol, S.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • This paper presents a numerical analysis of transient magnetic diffusion in a melt-cast-processed BSCCO-2212 tube subjected to sinusoidal applied fields. The nonlinear f-$\lrcorner$ relation obtained by experiments in liquefied $N_2$ is used to find the magnetic diffusion coefficient. The magnetic flux density, shield current density and p-J$^2$ loss are considered. According to the result of this study, the shielding current density is varied with external applied field and coordinate in the superconductor tube. The result of analysis can be used to explain the response of a Supercon -ductor-Shield-Core-Reactor subjected to sinusoidal applied fields.

Annealing Effect on Magnetic Properties and Electromagnetic Absorption Behaviors for Fe-Cr Alloy Powder-Polymer Composites

  • Lee, Sung-Jae;Kim, Yoon-Bae;Lee, Kyung-Sub;Kim, Sang-Woo
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.49-52
    • /
    • 2007
  • We investigated annealing effect of microforged powders on magnetic properties and electromagnetic absorption behaviors for ferromagnetic Fe-Cr metal alloy powder-polymer composites. The coercive properties greatly decreased with annealing temperature and the magnetic permeability had significantly increased after microforging and subsequent annealing treatment, due to a reduction in lattice strain of the microforged powders. The power loss in the far field regime also had greatly increased after microforging and subsequent annealing treatment in frequency range from 50 MHz to 6 GHz. As a result, the electromagnetic absorption of ferromagnetic Fe-Cr alloy metal powder-polymer composites was highly improved because of the relaxation of the internal strain during annealing process.

Non-contact critical current measurement using hall probe (Hall probe를 이용한 비접촉 임계전류 측정)

  • Kim, Ho-Sup;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Kim, Tae-Hyung;Ko, Rock-Kil;Ha, Hong-Soo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.7-8
    • /
    • 2009
  • Non-contact critical current measurement apparatus was developed using hall probe which measures the magnetic field distribution across the width of superconducting tape. The hall probe consists of 7 independent hall sensors which lie in a line 600 ${\mu}m$. The difference between maximum and minimum magnetic field in the magnetic filed distribution is a main parameter to determine the critical current. As preliminary research, we calculated the magnetic field intensity at the middle sensor, which is a minimum magnetic field and generated by the circular shielding current modeled by Bean model. We confirmed that there are some parameters that affect on the minimum magnetic field; the distance between superconducting layer and hall sensor, the width of superconducting tape, and the critical current distribution across the width of superconducting tape. Among these parameters, the distance between superconducting layer and hall sensor highly influences on the minimum magnetic field.

  • PDF

Neutronics analysis of the ion cyclotron resonance heating antenna of the China Fusion Engineering Test Reactor

  • Gaoxiang Wang;Chengming Qin;Shanliang Zheng;Yongsheng Wang;Kun Xu;Huiqiang Ma
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3236-3241
    • /
    • 2024
  • Ion cyclotron resonance heating (ICRH) is an important auxiliary heating method applied to the China Fusion Engineering Test Reactor, which can effectively heat the ions and electrons in plasma. Owing to the harsh nuclear environment, neutronic analyses are required to verify tritium self-sufficiency and neutron-shielding requirements. In this study, a neutronics analysis of the ICRH antenna was conducted using the COre and System integrated engine for Reactor Monte Carlo (cosRMC) code to estimate the neutron flux, radiation damage, nuclear heating, gas generation rate of key components, and tritium breeding ratio (TBR), providing data support for the subsequent optimization of the shielding design. In addition, the neutron flux of the coils around the antenna was calculated to prevent the entry of neutrons that damage the magnetic field coils through the gaps between the port plugs and antenna, and the shielding effects of the port-plug antenna on the surrounding components were analyzed. Finally, the results obtained using the cosRMC and MCNP codes were compared, which and presented good agreement, thus verifying the reliability of the neutronic analysis using the cosRMC code.

A Study on the MEG Imaging (MEG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.123-128
    • /
    • 2005
  • Magnetoencephalography (MEG) is the measurement of the magnetic fields produced by electrical activity in the brain, usually conducted externally, using extremely sensitive devices such as Superconducting Quantum Interference Device (SQUID). MEG needs complex and expensive measurement settings. Because the magnetic signals emitted by the brain are on the order of a few femtoteslas (1 fT = 10-15T), shielding from external magnetic signals, including the Earth's magnetic field, is necessary. An appropriate magnetically shielded room is very expensive, and constitutes the bulk of the expense of an MEG system. MEG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other brain activity measurement techniques such as electroencephalography (EEG), positron emission tomography (PET), single-photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI). MEG combines functional information from magnetic field recordings with structural information from MRI. The clinical uses of MEG are in detecting and localizing epileptic form spiking activity in patients with epilepsy, and in localizing eloquent cortex for surgical planning in patients with brain tumors. Magnetoencephalography may be used alone or together with electroencephalography, for the measurement of spontaneous or evoked activity, and for research or clinical purposes.

  • PDF

Calculation of induced currents and analysis of shielding effectiveness in shield (유한폭 무한장 차폐판의 차폐효과 해석)

  • Kang, Dael-Ha;Park, Sang-Ho;Park, Yun-Dong;Shim, Jae-Gu;Rho, Il-Soo;Kim, Ku-Song;Kim, Huy-Chil
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.549-550
    • /
    • 2011
  • In this study simple formula of magnetic field in case of shield with finite-width infinite-length were deduced. By using these formula calculation is very fast and programing is easy. The formula are applicable to analysis of shielding effectiveness and the design for shield of distribution lines.

  • PDF

Magnetic Fields Reduction Characteristics of Multi-layer Shielding Wear for a Worker Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 이중 차폐복 자계저감 특성검토)

  • Min, Suk-Won;Park, Jun-Hyeong;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1465_1466
    • /
    • 2009
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker in case he weared a multi-layer shielding cloth. We know these were lowest when high permeability materials such as silicon and permalloy were applied to the interior of a suit and high conductivity materials such as copper were to the exterior.

  • PDF