• Title/Summary/Keyword: Magnetic Shield

Search Result 103, Processing Time 0.026 seconds

A study on the electrostatic and magnetic flux cut off effect using anti-magnetic material (반자성 물질에 의한 전자기차단효과에 관한 연구)

  • Hwang, Yoon-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1473-1480
    • /
    • 2008
  • Bisumus has a low melting point, making it easier to handle. This allows us to test what type of effect diamagnetism has on electro static and magnetic field shields. However, the actual materials for experimentation have only ever been manufactured cylindrically, and so there have been no recorded cases of measurements to this effect. To understand what kind of effect pure bisumus as diamagnetism has on electro static and magnetic shields in comparison to other materials, bisumus, along with copper, aluminum and iron 스텐도, were used to make a cylinder each. These cylinders were then used to measure and compare the electro static shield and magnetic shield at different bands of frequencies, starting from a low frequency. As shown on the graph/chart/diagram, the best results were recorded for copper and bisumus as diamagnetism in an electro static field. In terms of magnetic shielding, iron provided the best results, as expected, whereas bisumus displayed minimal effect.

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Calculation of induced currents and analysis of shielding effectiveness in shield (유한폭 무한장 차폐판의 차폐효과 해석)

  • Kang, Dael-Ha;Park, Sang-Ho;Park, Yun-Dong;Shim, Jae-Gu;Rho, Il-Soo;Kim, Ku-Song;Kim, Huy-Chil
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.549-550
    • /
    • 2011
  • In this study simple formula of magnetic field in case of shield with finite-width infinite-length were deduced. By using these formula calculation is very fast and programing is easy. The formula are applicable to analysis of shielding effectiveness and the design for shield of distribution lines.

  • PDF

Physical ppropperties in Rare-earth Compounds

  • Takashi, Suzuki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.18-18
    • /
    • 1998
  • F First I will introduce our works how to improve the crystal growth t technique for Rare earth pnictides and chalcogenides. All these substances h have hi양1 vapor pressure and high melting print up to 3$\alpha$)()C. 까len we employ m the tungsten or molybden crucibles and enclose the sample by 빼e welding of m the lid with high current electron beam. We cannot elevate the temperature up t to 3$\alpha$)()C without suitable radiation shield because rate of radiation loss r rapidly increase in such a high temperature regions. There were no good r radiation shield but we discovered that the p-BN could work as an excellent r radiation shield after checking of the many substances. S Secondly I will show several interesting and unusual 뻐ysical properties of obtained crystals under high magnetic field, hi양1 pressure and also i including angle resolve photoemission spectroscopy. I will stress the p properties of the low carrier concentration with strong correlation on C댐, U USb and Yb4As3

  • PDF

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Electromagnetic Characteristics of High-temperature Superconducting Field Coil for a 1MW class Superconducting Motor (1MW급 초전도 모터용 고온초전도 계자코일의 전자기적 특성)

  • Baik, S.K.;Sohn, M.H.;Lee, J.D.;Lee, E.Y.;Kwon, Y.K.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Park, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.661-662
    • /
    • 2006
  • On the contrary of a conventional motor with very narrow air-gap, it is difficult to calculate the accurate magnetic field distribution and the performance of an air-cored superconducting motor by 2 dimensional analysis, which does not use high permeability material except outer machine shield. This paper aims to do analysis of magnetic field and force distribution from the 3 dimensional modelling of a 1MW class superconducting synchronous motor. Especially, the field coil composed of Bi-2223 high-temperature superconductor and the outer machine shield are modelled by finite element analysis software according to their structures and the self-inductance and Lorentz force are calculated based on the 3 dimensional magnetic field calculation.

  • PDF

Investigation on the inductive and resistive fault current limiting HTS power cable

  • Lee, Sangyoon;Choi, Jongho;Kim, Dongmin;Kwon, Yonghyun;Kim, Seokho;Sim, Kideok;Cho, Jeonwook
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.59-63
    • /
    • 2014
  • HTS power cable bypass the fault current through the former to protect superconducting tapes. On the other hand, the fault current limiting (FCL) power cable can be considered to mitigate the fault current using its increased inductance and resistance. Using the increased resistance of the cable is similar to the conventional resistive fault current limiter. In case of HTS power cable, the magnetic field of HTS power cable is mostly shielded by the induced current on the shield layer during normal operation. However, quench occurs at the shield layer and its current is kept below its critical current at the fault condition. Consequently, the magnetic field starts to spread out and it generates additional inductive impedance of the cable. The inductive impedance can be enhanced more by installing materials of high magnetic susceptibility around the HTS power cable. It is a concept of SFCL power cable. In this paper, a sample SFCL power cable is suggested and experimental results are presented to investigate the effect of iron cover on the impedance generation. The tests results are analyzed to verify the generation of the inductive and resistive impedance. The analysis results suggest the possible applications of the SFCL power cable to reduce the fault current in a real grid.

Plasma Uniformity Control Technology for Dry Etching (ICP Dry etcher) Equipment for Medium and Large Displays (중·대형 디스플레이용 건식 식각(ICP Dry etcher) 설비의 플라스마 균일도 제어 기술)

  • Hong, Sung Jae;Jeon, Honggoo;Yang, Ho Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.125-129
    • /
    • 2022
  • The current display technology tends to be highly integrated with high resolution, the element size is gradually downsized, and the structure becomes complicated. Inductively coupled plasma (ICP) dry etcher of various types of etching equipment is a structure that places a large multi-divisional antenna source on the top lid, passes current to the Antenna, and generates plasma using the induced magnetic field generated at this time. However, in the case of a device of a large area size, a support that can withstand a load structurally is necessary, and when these support portions are applied, arrangement of antenna becomes difficult, which causes reduction in uniformity. As described above, the development of antenna source of a large area having a uniform plasma density on the whole surface is difficult to restrict hardware (H/W). As a solution to this problem, we confirmed the change in uniformity of plasma by applying two kinds of specific shape faraday shield(FICP) to the lower part of the large area upper lid antenna of 6 and 8th more than that generation size. In this thesis, we verify the faraday shield effect which can improve plasma uniformity control of ICP dry etcher equipment applied to medium and large displays.

A New Concept of Magnetic Cable for Safe Mobile Power Delivery

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.410-412
    • /
    • 2011
  • Magnetic cables that can deliver high frequency AC electric power safely for flammable or sensitive workplaces preventing from arcs and electric shocks are firstly proposed in this paper. To deliver the power for a long distance, several new magnetic cable structures which drastically reduce the parallel leakage flux by appropriate magnetic shield between the magnetic cables are suggested; hence, the output power can be improved more than ten times. The proposed magnetic cables are fully analyzed and verified by simulations and experiments with good agreement. The output power and efficiency for a prototype magnetic cable of 1.5m long and 1 cm gap between parallel cores were measured as 154W and 67 %, where the source current and frequency were 10 A and 20 kHz, respectively.

  • PDF

Magnetic Shielding Effectiveness Measurement of Magnetic Steel Sheets in ELF Range

  • Yeon, Kyo-Heum;Son, Derac;Park, Eon-Byeong;Lee, Jae-Young;Do, Kyung-Hwan;Park, Jae-Seg
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.173-176
    • /
    • 2008
  • In this study, a new kind of instrument for measuring the magnetic shielding effectiveness (MSE) was developed using a double yoke; one a magnetizing yoke and the other a sensing yoke. Using the developed instrument, the MSE could be measured for a steel sheet specimen in the ELF range, where the magnetic permeability contributes to the MSE at low frequencies and eddy currents contributes to the MSE high frequencies with < 0.1 dB reproducibility. The developed measuring method can be applied to quality control in a steel sheet company producing EMI/EMC shielding materials.