• 제목/요약/키워드: Magnetic Resonant

검색결과 232건 처리시간 0.022초

Performance analysis of atomic magnetometer and bandwidth-extended loop antenna in resonant phase-modulated magnetic field communication system

  • Hyun Joon Lee;Jung Hoon Oh;Jang-Yeol Kim;In-Kui Cho
    • ETRI Journal
    • /
    • 제46권4호
    • /
    • pp.727-736
    • /
    • 2024
  • Telecommunications through an electrically conductive medium require the use of carrier bands with very-low and ultralow frequencies to establish radiofrequency links in harsh environments. Recent advances in atomic magnetometers operating at very-low frequencies have facilitated the reception of digitally modulated signals. We demonstrate the transmission and reception of quadrature phase-shift keying (QPSK) signals using a multi-resonant loop antenna and atomic magnetometer, respectively. We report the measured error vector magnitude according to the symbol rate for QPSK modulation and analyze the bandwidth of a receiver based on the atomic magnetometer. The multi-resonant loop antenna noticeably enhances the bandwidth by over 70% compared with a single-loop antenna. QPSK modulation for a carrier frequency of 20 kHz and symbol rate of 150 symbols per second verifies the feasibility of demodulation, and the measured error vector magnitude and signal-to-noise ratio are 7.29% and 30.9 dB, respectively.

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

유전체에 삽입된 자기공진형 무선전력전송 공진기의 공진주파수 복원에 관한 연구 (Resonant Frequency Recovery of Resonator for Magnetic Resonant Wireless Power Transfer Inserted into Dielectric Material)

  • 강석현;정창원
    • 한국전자파학회논문지
    • /
    • 제29권12호
    • /
    • pp.992-995
    • /
    • 2018
  • 본 논문에서는 향후 인체 내장형 의료기기의 무선충전 및 지금까지는 발생하지 않은 다양한 유전체 내부로의 무선전력전송 시 유전체 매질의 전자기적 특성에 따른 효율 및 공진주파수 변화에 대한 공진기의 최적화 설계를 위해 공진기의 정전용량(capacitance)을 조정하는 방법과 공진기의 전후 표면에 공기층(air pocket) 설치 방법을 제안하였다. 본 연구결과는 추후 공진기를 둘러싼 다양한 유전체 환경에 대한 공진주파수의 설계 및 복원에 대한 기초 연구 자료로 활용될 수 있다.

무선 유도 및 공진 충전방식의 전송효율 연구 (A Study on Transmission Efficiency of Wireless Power Induction and Resonant Charging Methodologies)

  • 노영환
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.747-750
    • /
    • 2019
  • 웨어러블 디바이스는 일상생활에서 실질적으로 필수적이며 사용자들에게 편리하게 이용되고 건강관리와 의학 분야 등에 활용되고 있다. 전력분야에서 전원 배터리의 사용시간의 한계를 극복하고 효율적인 충전방법에 관한 많은 연구가 진행되고 있다. 무선전력전송은 전선을 사용하지 않고 무선으로 전기장을 부하에 전력을 전달하는 기술이다. 이 전송기술은 저 전력의 스마트폰에서부터 고 전력을 사용하는 철도 충전시스템까지 응용분야가 다양하다. 충전방식은 유도방법과 자기공진방법의 2 종류로 나누는데 자기공진주파수는 13.45 Mhz를 사용하였다. 본 연구에서는 전송효율을 측정 비교하기 위하여 2 종류의 하드웨어를 구현한 후 비교하는데 있다.

코어를 사용한 새로운 자기공진형 코일구조 (A New Coil Set with Core for Magnetic Resonant Systems)

  • 허진;임춘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.625-626
    • /
    • 2012
  • A coupled magnetic resonance system (CMRS) using compact coil sets with core driven by a class-E inverter was proposed. The source and load coils of conventional CMRS were replaced with two coils containing core so that the system can be quite compact in size and easy to design due to a resonance frequency for all resonant tanks regardless of coupling factor. Experiments for 500 kHz switching frequency show 40% system efficiency.

  • PDF

통합된 PFC 인덕터와 공진변압기의 자기모델링 연구 (Analysis of an Integrated PFC Inductor and Resonant Transformer Based on Magnetic Modeling)

  • 메아스사란;품쏘피악;김은수;전용석;원종섭;김동희;허동영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2012
  • This paper describes the design and analysis of an integrated transformer magnetic core which comprises of two different power cores with PFC inductor and LLC resonant transformer magnetic cores. The equivalent magnetic circuit modeling approach is employed to analyze the variations in coupling coefficient and inductance in terms of air gaps under the operations of the respective power core. Simulation and experimental studies are performed with a fabricated prototype integrated core and their results are discussed.

  • PDF

The characteristic analysis of contact-less Power supply by 3D finite element method

  • Park, Han-Seok;Cho, Yun-Hyun;Jung, Hong-Sub;Woo, Kyung-il;Kim, Kyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.145-151
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of contact-less power supply by the 3D finite element method with a variation of the secondary core position. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. The magnetic coupling coefficients are obtained also. The power factors are obtained by simulation for the magnetic coupling coefficients and compared.

가포화 자기스위치를 이용한 탈황탈질 시스템의 전원장치에 관한 연구 (A study on topology of the DeNOx, DeSOx using magnetic pulse compressors)

  • 김수홍;이용덕;김승모;김병섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2008
  • Generally, Capacitor charging power supply (CCPS) consist of the full-bridge inverter, LC resonant tank and capacitance load. The multi-connection systems are normally used for high voltage or high power application. In this paper, conventional parallel operation resonant type and proposed series operation PWM type CCPS for pulse corona occurrence of DeSOx, DeNOx system using magnetic pulse compressor make a comparison. The effect of proposed CCPS is verified by circuit characteristics analysis of parallel operation resonant type and series operation PWM type, and it is confirmed by simulation result.

  • PDF

공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석 (Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline)

  • 신한수;송혜진;변진규
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Integrated Magnetics를 적용한 고속 스위칭 및 고전력밀도 3 레벨 LLC 공진형 컨버터 (High Switching Frequency and High Power Density Three-Level LLC Resonant Converter using Integrated Magnetics)

  • 남경훈;박철완;배지훈;지상근;류동균;최흥균;한상규
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.551-554
    • /
    • 2017
  • This paper proposes a three-level LLC resonant converter using integrated magnetics (IM). Given that the switch voltage stress of the proposed converter is guaranteed to be half of the input voltage, the switching losses can be greatly reduced, thereby benefitting the high-frequency operation. To reduce the volume of reactive components such as transformers, high-frequency driving and planar core are applied. However, two resonant inductors and one transformer are required because of the three-level structure and the limited leakage inductance of the planar transformer for the resonant operation. Therefore, the effect of volume reduction is not very large. In order to solve these drawbacks, this paper proposes a new IM that integrates all magnetic elements used in the proposed three-level resonant converter by using the magnetizing inductor as a resonant inductor. The experimental results are presented by conducting a theoretical analysis of a prototype with 350 W to 800 kHz.