• Title/Summary/Keyword: Magnetic Resonance Imaging System

Search Result 495, Processing Time 0.028 seconds

Characteristic findings of proton magnetic resonance spectroscopy of primary central nervous system Iymphoma

  • Kim, Seung-Hun;Lee, Hui-Joong;Kim, Yong-Sun
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.25-25
    • /
    • 2003
  • Purpose: In order to characterise primary central nervous system Iymphomas (PCNSL) and to evaluate if 1H spectroscopy improves the preoperative differential diagnosis of other diseases. Method: We reviewed 11 MR imaging and 7 MR spectroscopy of 9 patient with Iymphoma confirmed by stereotatic biopsy.

  • PDF

Gradient Optimized Gradient-Echo Gradient Moment Nulling Sequences for Flow Compensation of Brain Images

  • Jahng, Geon-Ho;Stephen Pickup
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • Gradient moment nulling techniques require the introduction of an additional gradient on each axis for each order of motion correction to be applied. The additional gradients introduce new constraints on the sequence design and increase the demands on the gradient system. The purpose of this paper is to demonstrate techniques for optimization of gradient echo gradient moment nulling sequences within the constraints of the gradient hardware. Flow compensated pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. The design of the gradient moment nulling sequences requires the solution of a linear system of equations. A Mathematica package was developed that interactively solves the gradient moment nulling problem. The package allows the physicist to specify the desired order of motion compensation and the duration of the gradients in the sequence with different gradient envelopes. The gradient echo sequences with first, second, and third order motion compensation were implemented with minimum echo time. The sequences were optimized to take full advantage of the capabilities of the gradient hardware. The sequences were used to generate images of phantoms and human brains. The optimized sequences were found to have better motion compensation than comparable standard sequences.

  • PDF

Magnetic Resonance Spectroscopy Findings in Perro de Presa Canario Dogs with Spongy Degeneration of the Central Nervous System

  • Hong, Sae-Byel;Lee, In;Song, Yu-Mi;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.38 no.2
    • /
    • pp.89-93
    • /
    • 2021
  • 2-Month-old, three related Perro de Presa Canario dogs were evaluated for similar neurological symptoms like circling, head pressing, depressed mental status, hypermetria, and vocalization. On magnetic resonance imaging (MRI) of the brain, there were large, bilaterally symmetrical lesions with involvement of thalamus, and brainstem that were T2- and FLAIR-hyperintense and T1-iso/hypointense. There was no inclusion of cerebellum. Single-voxel spectroscopy acquisition was located in the thalamus where abnormalities were found in MR images. The results of magnetic resonance spectroscopy (MRS) showed markedly decreased N-acetylaspartic acid value. Euthanasia was performed and lesions consistent with the canine spongy degeneration. Alteration in metabolites in the brain can be determined by MRS, which helps in diagnosing degeneration/leukodystrophy of the central nervous system in dogs.

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

An Analysis on the Effect of the Increase in the Fee of Magnetic Resonance Imaging Deciphering of the External Hospital: Focusing on the Brain Magnetic Resonance Imaging (MRI 외부병원 판독 수가 인상의 효과 분석: 뇌 관련 자기공명영상을 중심으로)

  • Kim, Logyoung;Sakong, Jin;Jo, Minho;Wee, Seah;Lee, Jinyong;Kim, Yongkyu
    • Health Policy and Management
    • /
    • v.31 no.3
    • /
    • pp.261-271
    • /
    • 2021
  • Background: In 2018, the government increased the fee for the magnetic resonance imaging (MRI) image deciphering services of the external hospital to discourage the redundant MRI scan and to induce appropriate use of the MRI services. It is important to evaluate the effect of the policy to provide the basis for establishing other MRI-related policies. Methods: The healthcare data of the patients who had brain MRI scans were organized by episode and analyzed using the panel study in order to find out the effect of the MRI-related policy on the substitution effect and the medical expenses. Results: As a result of the increase in the fee of deciphering the MRI image, there has been an uplift in deciphering the MRI scan of the external hospital. It implies that more hospitals chose to use the MRI scan taken by other clinics or hospitals, rather than the MRI scan taken at their own facilities. Conclusion: The research results imply that a policy that facilitates the exchange of the medical image data between the hospitals is needed in order to establish an efficient management system of the healthcare resources. Such improvement is expected to reduce the social cost and contribute to the stability in the finance of national health insurance.

Cardiac Behçet's Disease Presenting with Right Ventricular Endomyocardial Fibrosis and Intracardiac Thrombosis: a Case Report

  • Choi, Eun Ji;Kim, Min Sun;Koo, Hyun Jung;Song, Jae-Kwan;Song, Joo Seon;Kang, Joon-Won;Yang, Dong Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.332-337
    • /
    • 2021
  • Behçet's disease is a chronic inflammatory disorder involving vessels of various sizes and organs, including the skin, joints, gastrointestinal tract, lungs, and cardiovascular system. The etiology of Behçet's disease is unclear, and clinical diagnosis is important in the absence of definitive laboratory or pathological findings diagnostic of Behçet's disease. Cardiac involvement is rare but might present as endocarditis, myocarditis, pericarditis, or intracardiac thrombosis. This report presents a case of Behçet's disease involving the heart in a 22-year-old man with unusual manifestations of right ventricular fibrosis and intracardiac thrombosis. Cardiac magnetic resonance imaging revealed multiple intracardiac thrombi and delayed diffuse subendocardial enhancement involving the right ventricle. No peripheral eosinophilia was detected. Endomyocardial biopsy showed mixed inflammatory cell infiltrates. Based on the patient's clinical history of oral ulcer and arthritis, a diagnosis of Behçet's disease was made considering the clinical, radiological, and histological findings. Intracardiac thrombi and endomyocardial fibrosis are rare manifestations of Behçet's disease, and the diagnosis is often a clinical challenge. Early diagnosis is important for appropriate management. Behçet's disease should be considered in the differential diagnosis of patients with intracardiac thrombosis and endomyocardial fibrosis of the right chamber.

A Study on the Performance Improvement for Magnetic Resonance Imaging Examination by Using the 6-Sigma Application (6-시그마 기법을 이용한 자기공명영상 검사 실적 개선에 대한 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.243-249
    • /
    • 2011
  • The purpose of the study was to improve of performance for Magnetic Resonance Imaging (MRI) examination in the department of radiology. It was performed DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, The fifth kinds of CTQ (critical to quality) by the kindness, the waiting time, the examination explanation, the waiting time and the waiting environment were selected by voice of customer. In the stage of measurement, the performed examinations and the reservation waiting time were measured each 1.77 and 1.69 sigma. In the stage of analysis, the potential key causes were determined the limited working hours and the difference of examination time of various entries. In the stage of improvement, MRI were performed with the operating system of 24 hours examination and the optimization of the difference of examination time by among of 30 minutes, 40 minutes, 50 minutes. Finally, the number of examinations and reserved waiting days were measured by each 3.17 and 1.71 sigma in the control stage.

Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

Pictorial Review of Mediastinal Masses with an Emphasis on Magnetic Resonance Imaging

  • Jin Wang Park;Won Gi Jeong;Jong Eun, Lee;Hyo-jae Lee;So Yeon Ki;Byung Chan Lee;Hyoung Ook Kim;Seul Kee Kim;Suk Hee Heo;Hyo Soon Lim;Sang Soo Shin;Woong Yoon;Yong Yeon Jeong;Yun-Hyeon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.139-154
    • /
    • 2021
  • Magnetic resonance imaging (MRI) has become a crucial tool for evaluating mediastinal masses considering that several lesions that appear indeterminate on computed tomography and radiography can be differentiated on MRI. Using a three-compartment model to localize the mass and employing a basic knowledge of MRI, radiologists can easily diagnose mediastinal masses. Here, we review the use of MRI in evaluating mediastinal masses and present the images of various mediastinal masses categorized using the International Thymic Malignancy Interest Group's three-compartment classification system. These masses include thymic hyperplasia, thymic cyst, pericardial cyst, thymoma, mediastinal hemangioma, lymphoma, mature teratoma, bronchogenic cyst, esophageal duplication cyst, mediastinal thyroid carcinoma originating from ectopic thyroid tissue, mediastinal liposarcoma, mediastinal pancreatic pseudocyst, neurogenic tumor, meningocele, and plasmacytoma.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF