Magnetic Resonance Imaging Grading Systems for Central Canal and Neural Foraminal Stenoses of the Lumbar and Cervical Spines With a Focus on the Lee Grading System

  • Jiwoon Seo;Joon Woo Lee
    • Korean Journal of Radiology
    • /
    • 제24권3호
    • /
    • pp.224-234
    • /
    • 2023
  • Magnetic resonance imaging (MRI) is a standard imaging modality for diagnosing spinal stenosis, which is a common degenerative disorder in the elderly population. Standardized interpretation of spinal MRI for diagnosing and grading the severity of spinal stenosis is necessary to ensure correct communication with clinicians and to conduct clinical research. In this review, we revisit the Lee grading system for central canal and neural foraminal stenosis of the cervical and lumbar spine, which are based on the pathophysiology and radiologic findings of spinal stenosis.

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서 (FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System)

  • 세이크 파이잘 아마드;김현덕
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

TAILORED RF PULSE를 이용한 NMR에서의 뇌 기능 영상법 (NMR Functional brain Imaging with the Tailored RF Pulse)

  • 노용만;조장회
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.21-24
    • /
    • 1993
  • The experimental results of visual stimulation with the tailored RF pulse are reported. Tailored RF pulse is used for the susceptibility effect imaging. Around 25% signal change of visual cortex area is detected during photic stimulation. Interestingly, with the tailored RF pulse, the signal intensity of visual cortex is deceased during photic stimulation. It is, however, increased with normal $T_2$ weighted imaging. The comparison between normal $T_2$ weighted imaging and the tailored RF pulse imaging are performed with 4T NMR system and the results with human volunteer are also presented.

  • PDF

A Case of Idiopathic Infratentorial Superficial Siderosis

  • Shin, Daeun;Yang, Seok-Yul;Kim, Youngwook;Ryu, Ho-Sung;Lee, Hoseok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.51-54
    • /
    • 2020
  • Superficial siderosis is attributed to hemosiderin deposition in the subpial layers of the nervous system. The clinical features of infratentorial superficial siderosis (ISS) are hearing loss, cerebellar ataxia, and corticospinal tract signs and the most common cause of idiopathic ISS is a dural defect. As magnetic resonance imaging (MRI) has advanced, the diagnosis of infratentorial superficial siderosis can be confirmed by unique radiological findings in MRI. Here, we report on a female patient diagnosed with idiopathic ISS by means of clinical symptoms and radiological findings.

En Plaque Tuberculoma: a Case Report

  • Kim, Young-eun;Lee, Donghoon;Hwang, Hokyeong;Kim, Minji
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.200-205
    • /
    • 2016
  • In Korea, tuberculosis is still common disease. Central nervous system tuberculosis can manifest in a variety of forms, including tuberculous meningitis, tuberculous cerebritis, tuberculoma, tuberculous abscess, and miliary tuberculosis. Although intra-axial tuberculomas are the more common type of CNS tuberculosis, extra-axial lesions are rarely encountered. En plaque tuberculoma is an extremely rare presentation of intracranial tuberculosis with mimicking primary or secondary meningeal neoplasia. We describe a rare case of an en plaque tuberculoma accompanied by tuberculous meningitis and tuberculomas.

A Case of Widespread Cavernous Malformations of the Central Nervous System Associated with Acute Neurologic Deficit

  • Noh, Kyung Chul;Chung, Sung Eun;Lee, Dokyung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권1호
    • /
    • pp.34-37
    • /
    • 2017
  • A 45-year-old female visited our clinic due to sudden right leg weakness and sensory loss. Brain and spinal cord magnetic resonance imaging showed widespread cavernous malformations. Cavernous malformation in L1 spine area was accompanied by a subacute stage hematoma with perilesional edema. Sensory loss subsided after corticosteroid therapy. Usually, neurologic deficit by spinal cavernous malformation appears more chronically in the adults compared to children. Treatment options are difficult to establish in a case with multiple cavernous malformations. Identifying hemorrhagic lesions by extensive neuroimaging evaluation could be helpful to select the treatment target for cavernous malformation.

Anti-Myelin Oligodendrocyte Glycoprotein Syndrome with Findings Resembling "Snake-Eye Appearance": a Case Report

  • Hong, Sujin;Yi, Jisook;Lee, Ho-joon;Hahn, Seok;Lim, Yun-jung;Lee, Yedaun;Shin, Kyong Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.189-192
    • /
    • 2021
  • Anti-myelin oligodendrocyte glycoprotein (anti-MOG) syndrome is an immune-mediated inflammatory condition of the central nervous system, which usually involves spinal cord and optic nerves. Herein, we studied the case of a 57-year-old female patient who presented with acute/subacute symptoms of sphincter dysfunction, paraparesis, and ocular pain. The patient was diagnosed with anti-MOG syndrome with findings resembling snake-eye appearance (SEA), characterized by nearly symmetrical round high signal intensity lesions located at anterior horns (gray matter) on T2-weighted image.