• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.025 seconds

A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer (레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구)

  • 정상화;신병수;이경형
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.155-158
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

Development of Compliance Emulator System (콤플라이언스 에뮬레이터 시스템의 개발)

  • Park, Chan-Won;Shin, Young-kyun
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.351-359
    • /
    • 1999
  • If the tactile sense is introduced to engineering and industries, it may provide more realistic virtual tactile sensing to human and it is possible to develop product that satisfy various consumer's taste. This paper presents a compliance emulator system as a new concept of tactile reproduction simulator which uses magnetic levitation in order to minimize friction and emulates compliance only along the vertical direction. Compliance is one of the important mechanical properties of the object related to tactile sensing of the human. The implemented system equipped with an analog LVDT sensor for a position sensor and employs a PD control with gravity compensation to emulate the specified compliance. To compensate the limited range of the system, the method of attaching the spring with various magnitude of stiffness to the system is adopted and its preliminary test is performed to confirm the validity of the method.

  • PDF

A Study on Transport Mechanism of the Ultrasonic Transporting System using Laser Scanning Vibrometer (Laser Scanning Vibrometer를 이용한 초음파 이송시스템의 이송 메커니즘에 관한 연구)

  • 정상화;신병수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.841-844
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

Magnetic, Electric field and Flowing analysis of pole with the Cylinder-wire-magnet type (Cylinder-wire헝 전극구성의 전자계 및 유체유동해석)

  • Lee, D.H.;Park, S.H.;Park, J.Y.;Kim, J.D.;Go, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1798-1800
    • /
    • 1997
  • Object of this paper is to find the best shape of cylinder, flowing velocity of gas and state of pole with the cylinder wire magnet type. Also it is to analysis phenomena arising in the cylinder. So that general program FLUX2D has used for magnetic and electric field analysis at the cylinder wire magnet type. General program PHOENICS has used for cold or hot gases flowing analysis at the cylinder wire type with magnet.

  • PDF

A comparative study of nondestructive geomagnetic survey with archeological survey for detection of buried cultural properties in Doojeong-dong site, Cheonan, Chungnam Province (매장문화재 확인을 위한 자력탐사 및 발굴 비교연구: 충남 천안시 두정동 발굴지역)

  • Suh, Man-Cheol;Lee, Nam-Seok
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.3
    • /
    • pp.175-184
    • /
    • 2000
  • A nondestructive experimental feasibility study was conducted using magnetometer to find buried cultural objects at pottery and steel matters in low-relief mountaineous area of Doojeong-dong, Cheonan, Chungnam Province from May 23 to July 18, 1998. Magnetic survey was carried out with $20cm{\times}20cm$ grid in a site of $20m{\times}40m$ before excavation, and the distribution of magnetic anomalies was compared with the results of excavation. Magnetic sensor was located on the surface of ground during the magnetic survey on the basis of an experimental result. Positive magnetic anomalies of maximum 130 nT are found over a pair of potteries. Magnetic anomaly map reveals several anomalous points in the 1st and 4th quadrants of the survey site, from where potteries and their fragments were confirmed. Six points out of seven points cprrelated with magnetic anomaly are found contain earthwares, whereas a magnetically uncorrelated location produced earthware made of unbaked clay. Steel waste such as cans and wires hidden in soil and bushes also influenced magnetic anomalies. Therefore, it is better to remove such steel wastes prior to magnetic survey if possible. Some magnetically anomalous points produced no archaeological object on excavation. This may be explained by shallower level of excavation than burial depth.

  • PDF

A study on the dynamic characteristics of exciting Flexural beam by ultrasonic wave (초음파에 의해서 가진되어지는 Flexural Beam의 동특성에 관한 연구)

  • Jeong, Sang-Hwa;Shin, Sang-Moon;Kim, Gwang-Ho;Lee, Sang-Hee;Kim, Ju-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.792-796
    • /
    • 2006
  • In recent years, the semiconductor industry and the optical industry is developed rapidly. The recent demand has expanded for optical components such as a optical lens, a optical semiconductor and a measuring instrument. Object transport systems are driven typically by the magnetic field and the conveyer belt. Recent industry requires more faster and efficient transport system. However, conventional transport systems are not adequate for transportation of optical elements and semiconductors. Because conveyor belts can damage precision optical elements by the contact force and magnetic systems can destroy the inner structure of semiconductor by the magnetic field. In this paper, the levitation transport system using ultrasonic wave is developed for transporting precision elements without damages. This transport system is using 2-mode ultrasonic wave excitation and flexural beam modes shapes are evaluated. It compared simulation results with experimental results

  • PDF

Development of Vibrator for Magnetic Resonance Elastography (자기공명 탄성계수 영상법을 위한 진동기의 개발 및 기초실험)

  • Lee, Tae-Hwi;Suh, Yong-Seon;Kim, Young-Tea;Lee, Byung-Il;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.75-83
    • /
    • 2007
  • Elasticity is an important physical property of biological tissues. Differences in elasticity can help facilitate the diagnosis of tumors and their extent. Magnetic Resonance Elastography (MRE) tries to visualize images of tissue elasticity by externally applying shear stress on the surface of an imaging object. Applied shear stress induces internal displacements that can be measured from MR phase images. In order to conduct MRE imaging experiments, we need to first develop a vibrator. We found that there does not exist enough technical information to design the MRE vibrator. In this paper, we describe the theory, design and construction of an MRE vibrator. We report the performance of the developed vibrator using two different test methods. We found that the vibrator successfully induces enough internal displacements that can be imaged using an MRI scanner. We suggest future studies of numerous MRE imaging experiments using the vibrator.

CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)

  • Jeon, Ki-Wan;Lee, Chang-Ock;Kim, Hyung-Joong;Woo, Eung-Je;Seo, Jin-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.279-287
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality providing cross-sectional images of a conductivity distribution inside an electrically conducting object. MREIT has rapidly progressed in its theory, algorithm and experimental technique and now reached the stage of in vivo animal and human experiments. Conductivity image reconstructions in MREIT require various steps of carefully implemented numerical computations. To facilitate MREIT research, there is a pressing need for an MREIT software package with an efficient user interface. In this paper, we present an example of such a software, called CoReHA which stands for conductivity reconstructor using harmonic algorithms. It offers various computational tools including preprocessing of MREIT data, identification of boundary geometry, electrode modeling, meshing and implementation of the finite element method. Conductivity image reconstruction methods based on the harmonic $B_z$ algorithm are used to produce cross-sectional conductivity images. After summarizing basics of MREIT theory and experimental method, we describe technical details of each data processing task for conductivity image reconstructions. We pay attention to pitfalls and cautions in their numerical implementations. The presented software will be useful to researchers in the field of MREIT for simulation as well as experimental studies.

High-Precision Control of Magnetic Levitation System

  • Jeon, Jeong-Woo;Caraiani, Mitica;Lee, Ki-Chang;Hwang, Don-Ha;Lee, Joo-Hoon;Kim, Yong-Joo;Nam, Taek-Kun;Kim, Sung-Shin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2575-2580
    • /
    • 2005
  • In this paper, we address two position control scheme; the lead-lag control and the sliding mode control for a stage system, which is levitated and driven by electric magnetic actuators. This consists of a levitating object (called platen) with 4 permanent magnetic linear synchronous motors in parallel. Each motor generates vertical force for suspension against gravity and propulsion force horizontally as well. This stage can generate six degrees of freedom motion by the vertical and horizontal forces. Dynamic equations of the stage system are derived simply. The sliding mode control algorithm is more effective than the lead-lag control algorithm to reduce effects from movements and disturbances of other axis.

  • PDF

FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System (소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서)

  • Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.