• 제목/요약/키워드: Magnetic Field Sensors

Search Result 249, Processing Time 0.026 seconds

A Study of Slope Movements Using Fibre Optic Distributed Deformation Sensor (분포형 광섬유센서를 활용한 지표이동 측정에 관한 연구)

  • Chang, Ki-Tae
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.2
    • /
    • pp.75-80
    • /
    • 2005
  • Optical fibre sensors have shown a potential to serve real time health monitoring of Slope and structure. They can be easily embedded or attached to the structures and are not affected by the electro-magnetic field. Furthermore, they have the flexibility of the sensor size and very highly sensitive. In this study, we conducted several laboratory on slope and field tests using a novel optical sensor based on Brillouin scattering and PVC pipe. One of the advantages of this technique is that the bare fibre itself acts as sensing element without any special fibre processing or preparation. Test results have shown that BOTDR can be a great solution for sensor systems of Slope.

  • PDF

A Study of Slope Movements using Fibre Optic Distributed Deformation Sensor (분포형 광섬유센서를 활용한 지표이동 측정에 관한 연구)

  • 장기태
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.475-482
    • /
    • 2002
  • Optical fibre sensors have shown a potential to serve real time health monitoring of Slope and structure. They can be easily embedded or attached to the structures and are not affected by the electro-magnetic field. Furthermore, they have the flexibility of the sensor size and very highly sensitive. In this study, we conducted several laboratory on slope and field tests using a novel optical sensor based on Brillouin scattering and PVC pipe. One of the advantages of this technique is that the bare fibre itself acts as sensing element without any special fibre processing or preparation. Test results have shown that BOTDR can be a great solution for sensor systems of Slope.

  • PDF

Magnetoresistive Effect in Ferromagnetic Thin Films( I ) (강자성체 박막(Fe-Ni, Co-Ni)의 자기-저항 효과에 관한 연구( I ))

  • Chang, C.G.;Yoo, J.Y.;Song, J.Y.;Yun, M.Y.;Park, J.H.;Son, D.R.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-34
    • /
    • 1992
  • In order to fabricate magnetoresistive sensor, Fe-Ni and Co-Ni alleys were evaporated on the slide glass and the silicon wafers. Saturation magnetic induction($B_{s}$), coercive field strength($H_{c}$) and magnetoresistance were measured for fabricated samples. The evaporated Fe-Ni thin films show that the saturation magnetic induction was 0.65 T, and coercive field strength was 0.379 A/cm, and this value was changed to 0.370 A/cm(//), 0.390 A/cm(${\bot}$), respectively after magnetic annealing. For the measurement of coercive field strength, magnetizing frequency of 1 kHz was used. For the fabricated sensor element, the change of magnetoresistance (${\Delta}R/R$) was excessively unstable due to oxidation in the process of fabrication. The evaporated Co-Ni alloy thin films show that saturation magnetic induction was 0.66 T, and coercive field strengthes were 5.895 A/cm(//), 5.898 A/cm(${\bot}$), respectively, after magnetic annelaing. The change of magnetoresistance(${\Delta}R/R$) was $3.6{\sim}3.7%$ of which value was excessively stable to room temperature. Fe-Ni thin film could have many problems due to large affinity in the process of fabrication of magnetoresistance sensor, but Co-Ni thin film could be a suitable material for fabrication of magnetoresistance sensor, because of its small affinity and definite magnetoresistance effects.

  • PDF

Major B-H Loop Measurement of Toroidal Shape Magnetic Powder Core (토로이드형 분말코어의 Major B-H Loop 측정)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.76-80
    • /
    • 2014
  • Toroidal cores made of metallic powder requires large magnetic field strength up to few decade kA/m to obtain major hysteresis loop. To overcome thermal heat generation problem from large exciting current during measurement, we have employed a real time hysteresis loop tracer which can digitize and calculate B-H signals in personal computer as real time. For example, when we magnetize specimen at 10 Hz frequency, we could display hysteresis loops 10 times per second. Using the real time hysteresis loop tracer, we could measure major hysteresis loop of toroidal shape metallic powder core at maximum flux density or maximum magnetic field strength to be measured within 5 second not to significant increasement of specimen temperature due to the heat dissipation from coil windings. For the constructed hysteresis loop tracer, we could measure hysteresis loop at magnetic field strength higher than 50 kA/m for the toroidal shape specimen.

Inductive Micro Thin Film Sensor for Metallic Surface Crack Detection (금속 표면결함 검출용 자기유도 마이크로 박막 센서)

  • Kim, Ki-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.395-400
    • /
    • 2008
  • Alternating magnetic field was used for detection of surface flaws on nonmagnetic and magnetic metallic specimens. The nondestructive sensor probe was composed of the planar coil with inductive magnetic thin film yoke as a sensing component and a single straight typed exciting coil. The planar inductive coil sensor with magnetic yoke was fabricated by sputtering, electroplating, dry etching and photolithography process. The alternative currents with the range of 0.1A to 1.0A (0.7 MHz to 1.8 MHz) were applied to the exciting coil. The specimens were prepared with the slit shaped artificial surface flaws (minimum depth and width; 0.5 mm) on metallic plate (Al; nonmagnetic metal and FeC; magnetic metal). The detected signal for the positions and shapes of surface flaws on specimens were obtained with high sensitivity and high signal to ratio. The measured output signals by the non-contacted scanning on surface of FeC specimen with micron-sized crack were converted to the images of the flaws. And these results were compared with the optical images, respectively.

Extraordinary Magnetomechanical Coupling as a Result of a Combined Magnetic Structural Transition in a New Class of Rare Earth Compound

  • Jiles, D.C.;Lee, S.J.;Han, M.;Lo, C.C.H.;Snyder, J.E.;Gschneidner, K.A.;Pecharsky, V.K.;Pecharsky, A.O.;Lograsso, T.;Schlagel, D.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • The new class of $Gd_5(Si_xGe_{1-x})_4$ compounds undergoes a simultaneous magnetic/structural phase transition giving a high level of strain that can be induced either by change in temperature or by application of a magnetic field. Profound changes of structural, magnetic, and electronic changes occur in the $Gd_5(Si_xGe_{1-x})_4$ system lead to extreme behavior of the material such as the giant magnetocaloric effect, colossal magnetostriction, and giant magnetoresistance. These unique material characters can be utilized for various applications including magnetic solid refrigerants, sensors, and actuators.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

Development of Magnetoimpedance Sensor Utilizing Soft Magnetic Amorphous Ribbon with Exchange Coupling and Application to Nondestructive Testing (교환결합을 가진 연자성 비정질 리본을 이용한 자기 임피던스 센서 개발과 비파괴검사 응용)

  • Yoon, Seok-Soo;Kim, Gun-Woo;Lee, Sang-Hun;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.401-406
    • /
    • 2008
  • Recently, portable magnetic sensors with high sensitivity are strongly required for various applications such as biosensor, nondestructive testing and directional sensor. A novel magnetic sensor system was developed by utilizing giant magnetoimpedance(MI) effect of soft magnetic ribbons. The sensor system consists of sensing head of $Co_{66}Fe_{4}Si_{15}B_{15}$ ribbon having asymmetric MI characteristics through exchange coupling produced by field-annealing in open air and circuit for signal processing. The sensor system showed almost linear characteristics in dynamic range of $-1\;Oe\;{\sim}\;1\;Oe$ and sensitivity of 10.5 V/Oe. The sensor was applicable to nondestructive testing system to detect defects in wire ropes.

Annealing Effects of Amorphous Cores for the Application of Flux-gate Sensors (Flux-gate 센서용 비정질 코아의 열처리효과)

  • 김용준;손대락;손동환
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.134-140
    • /
    • 2001
  • Flux-gate magnetometer was developed in 1930's, and it has been widely used for the low magnetic field measurements. In this work, we have employed amorphous ribbon 2714A produced by Allied Chem. Co. as sensor core material. To develop low noise, low power consumption, and high reliability flux-gate magnetometer, we have measured ac magnetic properties depending on the annealing conditions. As quenched state amorphous core shows high noise level and ac magnetic properties were changed under the condition of accelerated aging test, but amorphous ribbon, which was annealed under 350 $\^{C}$ during 1 hour, shows low noise level of 0.1 nT in the frequency range of dc∼10 Hz which was 10 times better than the as quenched amorphous ribbon. Under accelerated aging test, ac magnetic properties such as squareness and coercivity of the annealed samples show higher reliability and approached to a certain limiting value as exponential function. We can see that high reliability and low noise flux-gate magnetometer could be developed, if we consider this ac magnetic properties change in the sensor design.

  • PDF

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • v.6 no.4
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.