• Title/Summary/Keyword: Magnetic Ballast

Search Result 44, Processing Time 0.02 seconds

Analysis of Electrical Characteristics and Performance of Ballast for Dual Lamps (이등용 안정기의 전기적 특성 및 성능 분석)

  • Park, Yong-San;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.79-83
    • /
    • 2013
  • An electronic ballast and magnetic ballast are two major types of ballasts used in HID(High Intensity Discharge) lamp. Compared with magnetic ballasts which can last for over 30 years and are recyclable at the end of their long lifetime, electronic ballasts have very short lifetimes due to the use of the electronic devices. In this paper, we developed a magnetic ballast for dual lamps and analyzed electrical characteristics and efficiency. As the experimental results, we confirm that the magnetic ballast for dual lamps makes it possible to effectively reduce current, active and reactive powers than conventional ballast.

A Optimal Design method for Dimmable Magnetic Ballast Design for Metal Halide Lamps (메탈핼라이드 램프용 조도제어형 자기식 안정기의 최적 설계 방법)

  • Park, Chong-Yeon;Lee, Hyeon-Jin
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.177-182
    • /
    • 2009
  • The inductor which is used at low frequency as the main part of magnetic ballast consists of an iron core, a bobbin and coil. The conventional inductor design method is not suitable for the magnetic ballast because it has various variables and is not a unique method for the magnetic ballast. Thus, this paper presents the optimal design method for a lamination type inductor using a magnetic ballast for Metal Halide Lamps. Also, the optimal inductor design method is researched for inductors of dimming ballasts and ignitors that have a gate-triggered structure using a SCR thyristor. By the simulation and experimental results, we showed that the proposed design methods is valid.

  • PDF

The realization of the Dimmable Magnetic Ballast for HID Lamps by the Life Time Extension Method of the Relays (릴레이 수명 연장 방법에 의한 HID램프용 디밍 자기식 안정기의 구현)

  • Jung, Kwang-Hyun;Lee, Hyeon-Jin;Park, Chong-Yeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.516-522
    • /
    • 2009
  • The dimmable magnetic ballast which applies the variable inductor needs a switching process for the dimming process, and it consists of mechanical relays because of costs and reliabilities. However, it is hard to operate with correct timing in mechanical relay, so relays reduce their own life time in inductive applications. Moreover this creates a destructive problem at the switching process. The life time reduction of relays means the life time reduction of the ballast. Thus, in this paper, we described the problem at the witching process in the dimmable magnetic ballast with a variable inductor, which consists of relays and the soft AC switching method in order to solve the problems. As result, we achieved the improvement of the life time and reliability of the ballast.

Electrical and Optical Characteristics of Ceramic Metal Halide Lamp with Operating Electronic Ballast (세라믹 메탈할라이드 램프의 전자식 안정기 구동을 통한 전기적 광학적 특성에 관한 연구)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Hoo;Jang, Hyeok-Jin;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2238-2243
    • /
    • 2008
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp's properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical, optical and thermal characteristics are analyzed by comparing magnetic ballast with electronic ballast.

Development of a metal-halide lamp's electronic ballast (메탈핼라이드 집어등용 전자식 안정기 개발)

  • Park, Seong-Wook;Bae, Bong-Seong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.2
    • /
    • pp.116-125
    • /
    • 2013
  • Jigging and angling fishery is prevalent in the East Sea of Korea and this fishery needs many lamps to attract the fish. And the fishing boat uses 24~47 ballasts by the vessel's tonnage to turn on the fishing lamp. A 3.5kW magnetic-type ballast being currently used at many fishing boats can drive two 1.5kW metal-halide lamps. Meanwhile, this ballast has large weight (25kg) and volume. Therefore it is one of reason for the over-consumption of energy and the fire, resulted from overheat and electrical short, occurs occasionally because the ballast is installed at narrow and hot engine room. In addition, most of magnetic ballast has several problems such as periodic condenser replacement, low energy efficiency and making lamp short life, etc. So it is necessary to improve or develop newly the electronic ballast, which has to be smaller, lighter and more efficient. An electronic ballast was designed for the fishing boat by considering duration and electromagnetic interference in the study. Its weight and volume are respectably 40% and 66% compared to current ballast on the basis of PCB. The metal-halide lamp's spectrum of the designed ballast was nearly same to that of the current ballast in the test of lighting. In particular, the light stability was improved and there isn't any radio interference. As mentioned above, it is expected that the developed electronic ballast can replace current magnetic ballast because of many advantages related to energy-saving.

Development of a High-Efficient Magneric Ballast for Fluorescentlamps (고효율의 형광램프용 자기식 안정기의 개발)

  • 남택주;김희식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.121-128
    • /
    • 1998
  • A new magnetic ballast was designed and developed to get high luminous efficiency. The core material of new magnetic ballast was G-9 and its shape of core is modified. The diameter of the coil was upgraded to 0.5[mm], and a new power-saving circuit was designed for the semiconductor ignition starter. The experimental results of the ballast showed reduction of the electric loss in the magnetic ballast about 1.7Watt (0.5[%]). The luminous efficiency was increased by 6.2 lm/Watt (7.6[%]) and the ballast efficiency factor(BEF) of 1.09(7.6[%]). The prototype was tested through national standard testing procedure. A high efficient energy-using equipment (the second grade in the efficiency of energy consumption) was certified. The saving power of 1.7[W] was shown by lighting appratus for fluorescent lamps. The result will be used for the high efficient magnetic ballast technology.nology.

  • PDF

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

Igniter design methods of the ballasts for Ceramic Metal Halide lamp (세라믹 메탈할라이드 램프용 안정기의 점화기 설계 방법)

  • Park, Chong-Yeun;Choe, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.75-81
    • /
    • 2010
  • We described the operating principles of two different type of igniters for lightning of Ceramic Metal Halide Lamp(CMHL) and also provide some useful comparisons. One is for magnetic ballast, the other one is for electronic ballast which operates lamp by low-frequency square-waveform. Ignition voltage of lamp depends on the structure of igniter, such as the length and electrical characteristics of cable, which make troubles for ignition in real sites. Therefore, we measured and analyzed ignition voltages from igniters which are used in magnetic and electronic ballast in cables at a distance of 5 meters between a lamp and a igniter to suggests an applicable solution in real sites.

  • PDF

Electrical Characteristics and Discharge Condition of Ceramic Metal Halide Lamp with Operating Property (구동특성에 따른 세라믹 메탈 할라이드 램프의 전기적 특성 및 방전현상에 관한 연구)

  • Jang, Hyeok-Jin;Kim, Nam-Gon;Yang, Jong-Kyung;Kim, Woo-Young;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.388-389
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp's properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF