• Title/Summary/Keyword: Machinery

Search Result 12,049, Processing Time 0.038 seconds

Removal Efficiency of Water Contents using Inertial Impaction Separator with Change in Relative Humidity (입구 습도 변화에 따른 관성 충돌 방식의 액적 분리장치의 수분제거효율 변화)

  • Song, Dong Keun;Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Kim, Hanseok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For design and incorporation of inertial pre-treatment separator, characteristics of removal of water contents with various operation conditions are needed. In this study, removal efficiency of water droplets at various flowrates (5-14 SCMM) and relative humidity (R.H.) conditions (40%, and 90%) has been investigated. At low R.H. condition, the removal characteristic is similar to the removal of solid particles. But, droplet growth resulting from the condensation of water vapor at high R.H. condition, is significant and it made increase in removal efficiency of droplet phase of water contents. For rapid removal of water contents, an effective method to enhancing condensation growth of water droplets is highly needed.

Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets (2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구)

  • Kim, Sumin;Kim, Hak-Joon;Kim, Myungjoon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.

Operation status of Agricultural Machinery Rental Service and its Improvement Plan (농업기계 임대사업 운영실태 및 개선방안)

  • Shin, Seung-Yeoub;Lee, Jung-Min;Kim, Yu-Yong;Noh, Jae-Seung
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.4
    • /
    • pp.61-69
    • /
    • 2016
  • In order to reduce the farmers' burden of purchasing agricultural machinery and address the shortage of farm workers, the government have been promoting agricultural machinery rental service since 2003. Despite of political purpose, the outcome of agricultural machinery rental service turned out to be adverse, high cost and low efficiency, by the pork barrel projects operated from some municipalities. Therefore, this study was aimed to improve the efficiency of agricultural machinery rental service by analyzing the operation status of agricultural machinery in local government. A questionnaire survey was conducted at 134 cities and counties in terms of rent type, management personnel, business budget, agricultural machinery ownership, rental performance, use rates, operational problems, and improvement plan. This study found that some agricultural machinery rental offices were only focused on the short-term rental service, which caused the increasing number of operating personnel, required facilities/equipment. The short-term rental service has a limitation for promoting the mechanization rate in dry-field farming. Therefore, it should be carried out along with the long-term rental service which a lessee maintains and manages agricultural machinery directly. Furthermore, the reasonable number of agricultural machinery based on regional circumstances should be considered to meet rental demand and collect the minimal rental fee for purchasing new agricultural machinery and replacing old ones.

A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone (고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구)

  • Kim, SooYeon;Kim, Jin-Seon;Sung, Jin-Ho;Han, Bangwoo;Kim, Yong-Jin;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

Molten Metal Inkjet System (용융 메탈 잉크젯 시스템)

  • Lee Taik-Min;Kang Tae-Goo;Yang Jeong-Soon;Jo Jeong-Dai;Kim Kwang-Young;Kim Dong-Soo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.585-586
    • /
    • 2006
  • In this paper, we present a design, analysis, fabrication and performance test of the novel DoD metal-jet system for application to the high-density and high-temperature-melting materials. Based on the theoretical analysis, we design the metal-jet print head system and fabricate the metal-jet system, which can eject the droplet of lead-free metal solder in the high-temperature. In the experimental test, we set up the test apparatus for visualization of the droplet ejection and measure the Ejected droplet volume and velocity. As a result, the diameter, volume and the velocity of the ejected droplet are about $65-70{\mu}m$, 145-180 pl and 4m/sec. We also fabricate vertical and inclined 3D micro column structures using the present molten metal inkjet system. The measured geometries of the micro column structures are about height of $2,100{\mu}m$, diameter of $200{\mu}m$ and aspect ratio of 10.5 for vertical micro column and $1,400{\mu}m$ of height and $150{\mu}m$ of diameter for $65^{\circ}$-inclined micro column, respectively.

  • PDF

Survey on the Regular Maintenance of Agricultural Machinery for the Full-Time Farmers (전업농가의 농업기계 정기 점검정비 실태조사)

  • 이성범;이종환;이운룡;강지원
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.323-330
    • /
    • 2001
  • The regular maintenance and repair status of major farm machinery such as power tiller, farm tractor, rice transplanter and combine harvester etc., were surveyed and analyzed for the full-time farmers in order to get basic information for promoting farm machinery productivity. The survey was carried out through 209 farmers from 9 provinces. The results of this study can be summarized as follows; 1. The regular maintenance of farm machinery was conducted at repair shop(49.5%) or dealer agency(12.0%), and also conducted by farmers at their house(34.9%). 2. For the status on the cleanness or exchange times of engine oil, fuel filter and air cleaner, most farmers conducted fewer times than the necessary times. And, 5.3%, 7.7%, and 2.9% of surveyed farmers experienced breakdowns due to the insufficient cleanness or exchange oil, fuel filer, and air cleaner, respectively. 3. Most farmers(76.1%) recognized the necessity of farm machinery training or education, and they preferred one week for the training period, simple or easy maintenance for the training level, agricultural technical center or farm machinery manufacturer for the training agency. 4. Complete recognition of operation manual and sufficient maintenance before-, during-, and after-operation for the farm machinery can minimize the breakdowns, enlarge the endurance prevent the safety accidents, and promote productivity of farm machinery. And, these can be accomplished by the thorough training or education for agricultural machinery.

  • PDF

Development of Capacitive Deionization with Calcium Alginate Based Cation Exchange Membrane for Hardness Control (칼슘알지네이트 이온교환막을 활용한 경도 제거용 축전식 탈염 기술 개발)

  • Yoon, Hongsik;Min, Taijin;Lee, Gunhee;Park, Inyong;Han, Bangwoo;Kang, Bo Sik;Ryu, Kyungha;Lee, Jiho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.563-571
    • /
    • 2021
  • In this study, calcium alginate based cation exchange membrane was prepared and used to develop membrane capacitive deionization (MCDI) system for effective hardness control. As a major result, the MCDI with Ca-alginate membrane showed 27% better deionization capacity than the MCDI with a commercial cation exchange membrane. This superior improvement in the deionization capacity was expected to be due to the high ratio of transport number/electrical resistance (Sc/Rratio) of Ca-alginate membrane. In addition, the MCDI with Ca-alginate membrane showed better deionization performance than the MCDI with Ca-alginate coating. This was because the space between the electrode and the Ca-alginate membrane was utilized for ion adsorption. The preliminary results indicated that the MCDI with Ca-alginate membrane can be a viable technique for the hardness control.

Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method (광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석)

  • Shin, Dongho;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Park, Inyong;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station (지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가)

  • Park, Dae Hoon;Hwang, Jungho;Shin, Dongho;Kim, Younghun;Lee, Gunhee;Park, Inyong;Kim, Sang Bok;Hong, Keejung;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.