Precise Test Sieves Calibration Method Based on Off-axis Digital Holography

  • Abdelsalam, Dahi Ghareab;Baek, Byung-Joon;Kim, Dae-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.146-151
    • /
    • 2011
  • We describe, throughout a Mach-Zehnder interferometric configuration, a new test sieves calibration method based on off-axis digital holography. The experiment is conducted on a test sieve of square openings. The nominal sieve opening is 1.00 mm with maximum individual opening of 1.14 mm in size. The recorded off-axis hologram is numerically processed using Fresnel transforms to obtain an object wave (amplitude and phase). From the reconstructed phase, the average size of the illuminated openings has been measured precisely. The proposed method can provide a real time solution for calibrating test sieves very precisely and with moderate accuracy.

Velocity and Temperature Visualization of Air Convection in Differently Heated Rectangular Cavity with Upper Channel (상부채널을 갖는 사각공간에서 열유속 변화에 따른 공기대류의 속도와 온도 가시화)

  • Lee, C.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.53-60
    • /
    • 2000
  • An experimental study was carried out in a cavity with upper channel and square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. The visualization system consists of 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000). Obtained result showed various flow patterns. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach-Zehnder are also compared in terms of constant heat flux.

  • PDF

Signal Stabilization of Optical Fiber Acoustic Sensor Using a Cylindrical Piezoelectric Stretcher (원통형 압전신장기를 이용한 광섬유 음향센서의 신호안정화)

  • Lee, D.-H.;Jho, M.-J.;Suh, S.-J.;Eun, H.-J
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.75-80
    • /
    • 1989
  • A Mach-Zehnder interferometer using single mode optical fiber was constructed which operates in homodyne detection scheme. Its response to air-borne soun pressure was examined experimentally. A signal stabilizer was developed for maintaining optical fiber interferometer in quadrature condition using a cylindrical piezoelectric stretcher. This maintains the optical fiber sensor at a maximum sensitivity in the presence of the phase drift caused by temperature fluctuation and other types of environmental disturbances.

  • PDF

Phase Stability of Injection-Locked Beam of Semiconductor Lasers (Injection-Locking된 반도체 레이저 광파의 위상 안전성)

  • 권진혁;김도훈
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.191-197
    • /
    • 1990
  • An experiment on the phase stability of injection-locked beam is done by using AlGaAs semiconductor lasers. The coherence of two beams from the master and slave lasers is measured by interference between the beams in the Twymann-Green interferometer. The phase change of the output beam of the slave laser as a function of the driving current is measured in the Mach-Zehnder interferometer consisted of the master and slave lasers and a value of 2.5radlmA is obtainccl.

  • PDF

Comparison of Signal to Noise Ratios in different configulation of optical coherence tomography systems (간섭계 형태에 따른 광단층 촬영장치의 SNR 비교)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.804-806
    • /
    • 2004
  • As a noninvasive imaging meathod, optical coherence tomography system has been extensively studied because it has some advantage such as imaging of high resolution, low cost, and compace size configuration. The optical power of the sample signal reflected from an object is usually very small in optical coherence tomography(OCT) due to absorption and scattering in a sample material. Furthermore, there happens a serious loss of sample signal power in a fiber coupler because it does not transfer to a photodetector but return to the optical source. In order to improve the SNR of OCT system, basic Michelson and Mach-Zehnder interferometer types were configured then, we compared simulation with measurement of reference sample Therefore, an On in configuration of Math-Zehnder interferometer was demonstrated in order to improve the signal to noise ratio

  • PDF

Chromatic dispersion measurement method with spectral interferometer (Spectral interferometer를 이용한 색분산 측정방법)

  • Lee, Ji-Yong;Lee, Seung-Rak;Kim, Deok-Yeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.307-308
    • /
    • 2007
  • We present a novel chromatic dispersion measurement method using a spectral domain interferometer for single mode optical fiber over a wide spectral range (200 nm). This technique is based on the Mach-Zehnder interferometer using a white light source and spectrometer. A phase was directly retrieved from a measured spectral interferogram to obtain relative group velocity, chromatic dispersion and dispersion slope. The measured results with the proposed method were compared with those obtained using a conventional measurement method. Those results have good agreement with each other. Our proposed method can simply, accurately, and quickly (< 500 ms) measure chromatic information for a short length of optical fiber as well as optical device.

  • PDF

Design of PLC Triplexer Using Three Waveguide Interferometer

  • Choi, Jun-Seok;Oh, Jin-Kyong;Lee, Dong-Hwan;Lee, Hyung-Jong;Kim, Sang-Duk
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.162-165
    • /
    • 2008
  • A novel planar lightwave circuit(PLC) triplexer using a three-waveguide interferometer(TWI) is proposed and examined using the transfer matrix and the beam propagation methods. The proposed triplexer consists of two three-waveguide couplers and three waveguides connecting the couplers. Simulation for the TWI triplexer shows the excess losses of 0.03 dB and 0.94 dB with the crosstalks of -22.3 dB and -14.5 dB in reception, respectively, for the wavelength of 1490- and 1550-nm, while showing the excess loss of 1.75 dB in transmission for the wavelength of 1310 nm. The proposed design shows compact feature as short as 11.5 mm for the refractive-index contrast of 0.45%.

Performance and Jitter Effects Analysis of Single Bit Electro-Optical Sigma-Delta Modulators (단일 비트 전자-광학 시그마-델타 변조기의 성능 및 지터 효과 분석)

  • Nam, Chang-Ho;Ra, Sung-Woong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.706-715
    • /
    • 2012
  • Electro-optical sigma-delta modulators are the core module of digital receiver to digitize wideband radio-frequency signals directly at an antenna. Electro-optical sigma-delta modulators use a pulsed laser to oversample an input radio-frequency signals at two Mach-Zehnder Interferometer(MZI) and shape the quantization noise using a fiber-lattice accumulator. Decimation filtering is applied to the quantizer output to construct the input signal with high resolution. The jitter affects greatly on reconstructing the original input signal of modulator. This paper analyzes the performance of first order single bit electro-optical sigma-delta modulator in the time domain and the frequency domain. The performance of modulator is analyzed by using asynchronous spectral averaging of the reconstructed signal's spectrum in the frequency domain. The reference value of time jitter is presented by analyzing the performance of jitter effects. This kind of jitter value can be used as a reference value on the design of modulators.

Requirements for Improvement in Transmission Performance for an Optical Delay Interferometer based Optical Duobinary Transmitters (광 간섭계를 이용한 광 듀오바이너리 송신기의 전송 성능 향상에 관한 조건 연구)

  • Lee, Dong-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.119-123
    • /
    • 2010
  • The transmission performance of 10Gb/s optical duobinary transmitters implemented by using a Mach-Zehnder(MZ) modulator and an optical delay interferometer is presented. We investigated the theoretical impact of transmission systems by the modulator driving voltage ratio(=driving voltage/switching voltage) and the optical interferometer time delay to improve transmission distance using computer simulation. By reducing the driving voltage ratio and optimizing the partial bit time delay, the transmission performance has been improved greatly.

Fiber Fabry-Perot Sensor using SLD Light Source (SLD 광원을 이용한 광섬유 패브리페로 센서)

  • Kim, Kwang-Soo;Lee, Byong-Yoon;Lee, Hong-Sik;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2186-2188
    • /
    • 2000
  • A fiberoptic sensor using an SLD as a light source has been studied. The sensor system employs an intrinsic fiber Fabry-Perot interferometer as a sensing tip and a fiber Mach-Zehnder interferometer as a processing one. A free loading test for temperature application shows that the fiberoptic sensor has a wide-dynamic range as well as high resolution. Due to the inherent property of the optical fiber itself and the intrinsic Fabry-Perot interferometer. the fiberoptic sensor gives obvious benefits when it is applied to harsh environments to monitor some physical parameters such as temperature, strain, pressure and vibration.