• Title/Summary/Keyword: MVA

Search Result 331, Processing Time 0.029 seconds

A study of excitation system of 500MVA short-circuit generator (500MVA급 단락발전기 여자시스템의 특성개선)

  • Jung, Heung-Soo;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun;Kim, Sun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.989-990
    • /
    • 2007
  • The excitation system of 500 MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time withstand current, short-circuit making and breaking current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit generator and the function and construction.

  • PDF

The analysis of troubleshooting in Kangjin UPFC (강진 UPFC 고장 실적 분석)

  • Kim, S.Y.;Yoon, J.S.;Jang, B.H.;Baek, D.H.;Kwak, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.211-213
    • /
    • 2005
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UPFC를 전남 강진군 강진변전소에 설치(2003. 5. 23준공) 운전하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병렬인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 준공이후 2년여에 걸친 운전으로, 강진 UPFC의 고장정지는 현저히 줄었다. 본 논문에서는 강진 UPFC의 주요 이벤트, 고장해소 및 설비의 신뢰성 향상을 위한 대응 조치들에 대해 정리하였다.

  • PDF

Development of 1MVA STATCOM for Wind Farm (풍력단지 적용을 위한 1MVA STATCOM 개발)

  • Jung, HongJu;Shin, HyunJin;Yeo, SangMin;Park, JungSoo;Lee, JeongMin;Suh, InYoung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.288-289
    • /
    • 2010
  • 다양한 신재생에너지의 발전원 확보를 위해서는 발전원의 출력 안정화가 필수적으로 수반되어져야 한다. 본 논문은 다양한 신재생에너지 발전원의 안정화를 위한 핵심기기 중 하나인 STATCOM의 설계 및 제작에 관한 내용이다. 개발 진행 중인 1MVA STATCOM은 제주도 행원 풍력발전의 전력품질을 개선하기 위해 설치될 예정으로 3-Level 인버터로 구성된 Stack과 LC 필터 그리고 변압기와 수배전반으로 구성되어 있다.

  • PDF

전(電)력질주 - "국내 전력의 한 페이지를 기록할 핵심 시험설비를 안전하게 운송하라!"

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.458
    • /
    • pp.46-49
    • /
    • 2015
  • 지난달 20일 경남 창원 제4부두. 한겨울 강한 바닷바람이 살을 에는 듯 세차게 불어왔지만 부두에 모인 사람들은 긴장감에 추위마저 느끼지 못했다. 이들은 국내 전력설비 역사의 한 획을 긋는 4,000MVA 대전력시험설비를 무사히 한국전기연구원 창원 본원으로 운송하기 위해 모인 사람들이었다. 드디어 밤 12시. 무게만 수백 톤에 이르는 설비들을 안전하게 운송하기 위한 특급수송 작전이 개시됐다. 팽팽한 긴장감 속에서 진행된 수송 작전 경과와 4,000MVA 대전력시험설비 증설사업의 의의에 대해 자세히 소개한다.

  • PDF

Feasibility Study of an HTS Transformer (고온 초전도 변압기 경제성 평가)

  • 김성훈;김우석;한송엽;최경달;주형길;홍계원
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.229-232
    • /
    • 2002
  • In this paper, we investigated the cost comparison between a 30 MVA high temperature superconducting(HTS) transformer and a conventional large power transformer, and estimated a break even point in time of the HTS transformer comparing to the conventional large power transformer. A value between 5, 000 and 8, 500 kA-m is chosen to calculate the price of HTS tape in a 30 MVA HTS transformer. And the number of cryocooler is decided by estimating the generated energy loss in HTS transformer.

  • PDF

발변전설비의 보호계전기술

  • 강계희;배주천
    • 전기의세계
    • /
    • v.43 no.4
    • /
    • pp.27-34
    • /
    • 1994
  • 전기기기의 설계, 제작기술 및 재두의 발달에 따라 근래의 발.변전 설비의 고장발생빈도는 매우 낮은 편이다. 그러나 이들 설비에 일단 고장이 발생하면 손상이 클 뿐 아니라 복구에 장기간이 소요될 경우가 많아 전력공급에 차질을 빚게 된다. 따라서 예상되는 각종 고장과 이상상태에 대비한 보호계전장치가 필요하게 되며 개별적인 보호장치에 적용 여부는 원칙적으로 그 고장에 대한 보호장치의 시설, 운전, 보수비용과 효과를 보호장치를 구비하지 않았을 경우 그 고장에 따른 위험성과 비교하여 판단하게 되나 실제로는 발.변전설비의 종류 및 특성, 용량등에 따라 경험적으로 선정되는 경우가 많다. 발.변전설비의 용량은 대체오 수백 KVA급으로부터 500MVA 또는 1000MVA정도의 대용량기기까지를 대상으로 보호계전기술을 서술한다.

  • PDF

Mean Value Analysis of a re-entrant line with production loss (생산 손실이 발생하는 재진입 라인의 평균치 분석)

  • 박영신;김수영;전치혁
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.265-267
    • /
    • 2000
  • 가공물을 한 개씩 작업하는 단일작업기계와 여러 개의 가공물을 한꺼번에 작업하는 배치 기계를 포함한 재진입 라인 시스템에서 각 기계가 고장이 일어날 수 있고, 불량품이 발생할 때, 이 시스템에서의 가공물의 생산주기를 구하는 방법을 Mean Value Analysis(MVA)를 이용하여 제시하고자 한다. 배치 기계와 고장 발생, 불량품 발생 등의 이유의 이런 시스템은 승법형 대기행렬 모형으로 모형화 할 수 없다. 본 논문에서는 각 기계에서의 체류 시간을 구하여 전 시스템의 생산 주기를 구하는 방법을 MVA 를 이용하여 제시한다.

  • PDF