• 제목/요약/키워드: MUSCLE ACTIVITIES

검색결과 1,303건 처리시간 0.041초

Hand Gesture Recognition Suitable for Wearable Devices using Flexible Epidermal Tactile Sensor Array

  • Byun, Sung-Woo;Lee, Seok-Pil
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1732-1739
    • /
    • 2018
  • With the explosion of digital devices, interaction technologies between human and devices are required more than ever. Especially, hand gesture recognition is advantageous in that it can be easily used. It is divided into the two groups: the contact sensor and the non-contact sensor. Compared with non-contact gesture recognition, the advantage of contact gesture recognition is that it is able to classify gestures that disappear from the sensor's sight. Also, since there is direct contacted with the user, relatively accurate information can be acquired. Electromyography (EMG) and force-sensitive resistors (FSRs) are the typical methods used for contact gesture recognition based on muscle activities. The sensors, however, are generally too sensitive to environmental disturbances such as electrical noises, electromagnetic signals and so on. In this paper, we propose a novel contact gesture recognition method based on Flexible Epidermal Tactile Sensor Array (FETSA) that is used to measure electrical signals according to movements of the wrist. To recognize gestures using FETSA, we extracted feature sets, and the gestures were subsequently classified using the support vector machine. The performance of the proposed gesture recognition method is very promising in comparison with two previous non-contact and contact gesture recognition studies.

환측 동기침법을 이용한 경추 추간판 탈출증 환자의 급성 압박성 요골신경마비 치험 1례 (A clinical study of the affected part acupuncture moving treatment on the acute radial nerve palsy patient who has Cervical Herniation)

  • 정훈;조남훈;박지용;박현민;배상은;홍남중
    • 대한한의정보학회지
    • /
    • 제17권2호
    • /
    • pp.73-81
    • /
    • 2011
  • Objectives : The purpose of this study is to evaluate the affected part acupuncture moving treatment for acute radial nerve palsy patient who has Cervical Herniation. Methods : We examined 1 patient with Radial nerve palsy who admitted Jaseng Hospital of Oriental Medicine. The patient was treated by the affected part acupuncture moving treatment including herbal mixture. Results : In this study, in the end of affected part acupuncture moving treatment, patient's condition has improved. Muscle strength was also increased. Conclusions : The affected part acupuncture moving treatment for acute radial nerve palsy was effective in restore of functional activities, but this treatment needs more study.

  • PDF

척수경막동정맥루로 인한 척수병증 환자의 색전술 이후 한의복합치료: 증례 보고 (Complex Korean Medical Treatment after Embolization for Myelopathy Due to Spinal Dural Arteriovenous Fistula: A Case Report)

  • 우현준;한윤희;이정한
    • 한방재활의학과학회지
    • /
    • 제31권3호
    • /
    • pp.105-114
    • /
    • 2021
  • A 38-year-old Korean man without any other history was diagnosed with myelopathy due to a spinal dural arteriovenous fistula. Following embolization and high-dose steroid therapy, the patient was treated with complex Korean medical therapies including acupuncture, pharmacopuncture, electro-acupuncture, Chuna manual therapy, herbal medicine, and cupping therapy in addition to conventional treatment. To assess the patient's improvement, international standard for neurological classification of spinal cord injury, Korean version of modified Barthel index, functional independence measure, spinal cord independence measure III, walking index for spinal cord injury II, modified Ashworth scale were used. After treatment, the muscle strength and sensory function of the lower extremities were improved, and the spasticity was reduced, resulting in a rapid improvement in performance of daily activities. These results suggest that complex Korean medical therapies may be effective for myelopathy, and further clinical studies are needed to clarify their effects.

Analysis of Postural Stability and Daily Energy Expenditure to Manage Tumor Patients' Functional Expectation

  • Caliskan, Emrah;Saygi, Evrim Karadag;Gencer, Zeynep Kardelen;Kurtel, Hizir;Erol, Bulent
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.491-499
    • /
    • 2018
  • Background: Advances in surgical techniques, implant technology, radiotherapy, and chemotherapy have increased the recovery chances of patients with bone sarcomas. Accordingly, patients' expectations on life quality have also increased, highlighting the importance of objective evaluation of the functional results of reconstruction. Methods: Thirteen patients with distal femoral endoprosthesis, who had been followed for an average of 2.9 years were evaluated. Postural stability, daily energy expenditure, muscle power, and range of motion were the four parameters analyzed in this study. The Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS) were used to assess postoperative function and examine correlations with other parameters. Results: Patients had sedentary activities in 84% of their daily lives. They exhibited a slower speed in the walk across test and a higher sway velocity in the sit-to-stand test (p = 0.005). MSTS scores were significantly correlated with the daily energy expenditure and walking speed. Conclusions: Objective functional results acquired from various clinics will provide significant data to compare reconstruction techniques, rehabilitation protocols, and surgical techniques. In this way, it will be possible to satisfy the expectations of patients that increase in relation to enhanced recovery.

Comparative In Vitro Toxicity Study of Docetaxel and Nanoxel, a Docetaxel-Loaded Micellar Formulation Using Cultured and Blood Cells

  • Do, Van Quan;Park, Kwang-Hoon;Park, Jung-Min;Lee, Moo-Yeol
    • Toxicological Research
    • /
    • 제35권2호
    • /
    • pp.201-207
    • /
    • 2019
  • Nanoxel-$PM^{TM}$ (Nanoxel) is a docetaxel-loaded methoxy-poly(ethylene glycol)-block-poly(D,L-lactide) (mPEG-PDLLA). This newly developed and marketed nanoformulation exhibits an improved pharmacokinetic profile, efficacy, and safety. Although the safety of Nanoxel to docetaxel as well as its bioequivalence must be clinically confirmed, all biological activities have not been examined in in vitro or in vivo studies. Here, the toxicity in a cultured cell system and the effects on blood cells were tested with Nanoxel and docetaxel. The in vitro cytotoxicity of Nanoxel was found to be comparable to or slightly lower than that of docetaxel depending on the concentrations tested or the cell types. Neither docetaxel nor Nanoxel induced erythrocytes hemolysis and produced reactive oxygen species up to $100{\mu}M$. However, Nanoxel was able to enhance the aggregatory response of platelets to collagen, whereas docetaxel attenuated such aggregation in a range of $50-100{\mu}M$, while thrombin-induced aggregation was not affected by either of them. Docetaxel or Nanoxel did not alter basal level of $Ca^{2+}$ and 5-hydroxytryptamine-evoked $Ca^{2+}$ transient in vascular smooth muscle cells. These results suggest that the mPEG-PDLLA micellar formulation alters the toxicological properties of docetaxel, and that extra cautions are needed when evaluating the safety of nanomedicine.

Effects of Multifactorial and Follow-up Programs Applying a Capacity Building Strategy: Focusing on Older Adults Living in a Urban-rural Complex Area

  • Han, Song YI;Ko, Young;Kim, Hee Ryang;Kim, Jiyoun
    • 지역사회간호학회지
    • /
    • 제30권2호
    • /
    • pp.243-255
    • /
    • 2019
  • Purpose: The purpose of this study is to examine effects of a multifactorial program for preventing the frailty of older adults and effects of a follow-up program applying a capacity building strategy. Methods: A quasi-experimental pretest-posttest design was used for the nonequivalent control group. The follow-up group (n=75) and non-follow-up group (n=68) received the same multifactorial program comprising muscle strength exercise, cognitive training, and psychosocial programs for 12 weeks. After completion of multifactorial program, the follow-up group took follow-up programs applying the capacity building strategy for following 12 weeks. The data of physical function, cognitive function, and psychological function, and self-rated health were collected from both groups three times: before intervention, after intervention, and 12 weeks after intervention. The data were analyzed using $x^2$ test and t-test. Results: In comparison with the non-follow-up group, the scores of Timed Up & Go Test, and physical activities energy expenditure were significantly improved in the follow-up group. Conclusion: These results indicate that a multifactorial program with follow-up adapting the strategies of capacity building for the older adults group is feasible to prevent the physical frailty in community.

회전근개 훈련용 기기 설계와 sEMG를 활용한 실험적 검증 (Design of Device for Rotator Cuff Training and Its Experimental Validation with sEMG)

  • 변상규;김재훈;정지용;김희영;신성욱;이응혁
    • 한국멀티미디어학회논문지
    • /
    • 제24권8호
    • /
    • pp.1035-1043
    • /
    • 2021
  • The shoulder is less stable than other joints, making it easier to onset of various shoulder disorders. In addition, limited range of motion and pain in the shoulder due to shoulder disorders restricts daily life and social activities. The problem with exercise therapy can be reduced in exercise effect by causing boredom through simple repetition of motion, thus reducing the patient's willingness to participate. Therefore, this paper aims to provide a treatment method that can induce active participation of patients by developing devices capable of passive, active, and resistance exercise and serious game contents using them. Furthermore, sEMG was used to verify whether the rotational exercise in the horizontal and vertical using serious game contents helps the shoulder movement actually. The measured sEMG signal was classified as 5 phases according to the angle of rotation and calculated the mean integrated EMG. The mean integrated EMG for the experimental results was higher in all phases when rotational was performed compared to those when both horizontal and vertical rotational exercise remained initial posture, indicating an increase in muscle activity.

상시 근골격 모니터링과 재활을 위한 온스킨 센서 디바이스 기술 (Imperceptible On-Skin Sensor Devices for Musculoskeletal Monitoring and Rehabilitation)

  • 박찬우;구재본;진한빛;김윤정;임채현;홍찬화;김혜진
    • 전자통신동향분석
    • /
    • 제37권2호
    • /
    • pp.30-41
    • /
    • 2022
  • As the society is superaging, the number of patients with movement disabilities due to musculoskeletal or nervous system illness is rapidly increasing. To improve public health and reduce medical expenses, it is essential to develop rehabilitation systems that allow patients to resume their daily-life activities. However, the existing musculoskeletal illness diagnosis and rehabilitation method is limited in terms of precision and efficiency because it is based on an empirical diagnosis and prescription without regard for individual characteristics. To overcome these limits, it is critical to design a novel concept of routine rehabilitation therapy device that is capable of inducing musculoskeletal balance by the precise analysis of musculoskeletal usage patterns via the motion and the muscle activity tracking of linked muscles. This study introduces the trend of on-skin sensor device technology for routine musculoskeletal monitoring and therapy. For on-skin rehabilitation systems, skin-adhesive and stretchable motion/posture, electromyography, pressure sensors, small-size and low-power wireless sensor interfaces, and user-friendly rehabilitation contents based on new algorithms are combined.

Spatial and Temporal Features of Motor Modules in an individual with Hemiparesis During the Curvilinear Gait: A Pilot Single-Case Study

  • LEE, Jae-Hyuk
    • 웰빙융합연구
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: This study aimed to investigate spatial and temporal features of motor control in an individual with hemiparesis during the curvilinear gait (CG) and proposed an exercise guideline. Research design, data and methodology: An individual aged 63 with hemiparesis by stroke disease was participated in the study. Autoencoder (AE) was used to extract four motor modules from eight muscle activities of the paretic leg during CG. After extraction, each module of four modules was operationally defined by numbering from M1 to M4 according to spatial and temporal features and compared with results reported in a previous study. Results: As a result, an individual with hemiparesis had motor module problems related to difficulty of weight acceptance (module 1), compensation for the weakness of ankle plantar flexor (module 2), a spastic synergistic pattern (module 3) and difficulty with transition from the swing to stance phase (module 4) in terms of spatial features. Also, a delayed activation timing of temporal motor module (module 2) related to the forward propulsion during CG was observed. Conclusions: Gait rehabilitation for the stroke will need to consider clinical significances in respect of the deterioration of motor module and provide the tailored approaches for each gait phase.

표고버섯, 양송이버섯, 배를 첨가한 홍두깨살의 연육 효과 (Effect of Letinus edodes, Agaricus bisporus and Pear Powder on Tenderization of Beef Eye of Round)

  • 남형경;김호경
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1009-1015
    • /
    • 2022
  • The purpose of this study was to investigate the effects of protease in Letinus edodes, Agaricus bisporus and Pear powder after freeze drying which has the ratio of 3% on the Tenderness of the Beef Eye of Round muscle. It were marinated in distilled water (Control), 3% Letinus edodes powder (L3), 3% Agaricus bisporus powder (A3), and 3% Pear powder (P3). As a result, enzyme activities were highest in Agaricus bisporus (p<0.001). There are significant difference in pH (p<0.001), color of the beef were slightly different between the C (control) group and the sample groups. The cooking loss showed the lowest value in the control and the highest value in the water holding capacity of Agaricus bisporus. In addition, Agaricus bisporus showed the lowest shear force values than the other sample groups(p<0.001).