• Title/Summary/Keyword: MTPA(Maximum Torque Per Ampere)

Search Result 49, Processing Time 0.023 seconds

Sensorless control of the Next Generation High Speed Drive System in low speed region (차세대 고속전철 저속영역에서의 센서리스 제어)

  • Jin, Kang-Hwan;Suh, Yong-Hun;Lee, Sang-Hyun;Kim, Yoon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.82-87
    • /
    • 2011
  • In this paper, a sensorless speed control system is designed for the next generation high speed railway at zero and low speed region. The applied vector control scheme is a maximum torque per ampere(MTPA) method to utilize reluctance torque of IPMSM. The designed sensorless control scheme is a rotating high frequency voltage signal injection method. To verify the designed system, a simulator for the vector controller and sensorless controller is implemented using Matlab/simulink.

Maximum Torque Control of Induction Motor Drive using Multi-HBPI Controller (다중 HBPI 제어기를 이용한 유도전동기 드라이브의 최대토크 제어)

  • Kang, Sung-Jun;Ko, Jae-Sun;Choi, Jung-Sik;Baek, Jeong-Woo;Jang, Mi-Geum;Kim, Soon-Young;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.363-366
    • /
    • 2009
  • The maximum output torque developed by the machine is dependent on the allowable current rating and maximum voltage that the inverter can supply to the machine. Therefore, to use the inverter capacity fully, it is desirable to use the control scheme considering the voltage and current limit condition, which can yield the maximum torque per ampere over the entire speed range. This controller is controlled speed and current using hybrid PI(HBPI) controller and estimation of speed using ANN. Also, this paper is proposed control of maximum torque per ampere(MTPA) of induction motor. This strategy is proposed which is simple in structure and has the honest goal of minimizing the stator current magnitude for given load torque. The performance of the proposed induction motor drive with maximum torque control using HBPI controller is verified by analysis results at dynamic operation conditions.

  • PDF

Development of Artificial Intelligent PI controller for Maximum Torque Control of Induction Motor (유도전동기의 최대토크 제어를 위한 인공지능 PI 제어기 개발)

  • Kang, Sung-Jun;Ko, Jae-Sub;Choi, Jung-Sik;Baek, Jung-Woo;Jang, Mi-Geum;Moon, Ju-Hui;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.587-588
    • /
    • 2010
  • The maximum output torque developed by the machine is dependent on the allowable current rating and maximum voltage that the inverter can supply to the machine. Therefore, to use the inverter capacity fully, it is desirable to use the control scheme considering the voltage and current limit condition, which can yield the maximum torque per ampere over the entire speed range. This controller is controlled speed using artificial intelligent PI(AIPI) controller. Also, this paper is proposed control of maximum torque per ampere(MTPA) of induction motor. The performance of the proposed induction motor drive with maximum torque control using AIPI controller is verified by analysis results at dynamic operation conditions.

  • PDF

Sensorless Vector Control for Maximum Torque of SynRM in the Field Weakening Region (약계자 영역에서 SynRM의 최대 토크제어를 위한 센서리스 벡터제어)

  • Lee, Jung-Chul;Chung, Dong-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.32-38
    • /
    • 2002
  • In this paper, a new approach for the SynRM(Synchronous Reluctance Motor) control which ensures producing MTPA(Maximum Torque per Ampere) over the entire field weakening region is presented. In addition, this paper presents a speed sensorless control scheme of SynRM using flux observer. Also, by adjusting the base speed for the field weakening operation according to the flux level, the current and voltage limit, the smooth and precise transition into the field weakening operation can be achieved. The validity of the proposed scheme is verified through simulation.

Optimal Design of Interior PM Synchronous Machines Using Randomly-Guided Mesh Adaptive Direct Search Algorithms (RG-MADS를 적용한 매입형 영구자석 동기전동기의 최적설계)

  • Kim, Kwang-Duck;Lee, Dong-Su;Jung, Sang-Yong;Kim, Jong-Wook;Lee, Cheol-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.216-222
    • /
    • 2012
  • Newly proposed RG-MADS (Randomly Guided Mesh Adaptive Direct Search) has been applied to the optimal design of Interior Permanent Magnet Synchronous Motor (IPMSM) which has the distinctive features of magnetic saturation. RG-MADS, advanced from classical MADS algorithm, has the superiority in computational time and reliable convergence accuracy to the optimal solution, thus it is appropriate to the optimal design of IPMSM coupled with time-consuming Finite Element Analysis (FEA), necessary to the nonlinear magnetic application for better accuracy. Effectiveness of RG-MADS has been verified through the well-known benchmark-functions beforehand. In addition, the proposed RG-MADS has been applied to the optimal design of IPMSM aiming at maximizing the Maximum Torque Per Ampere (MTPA), which is regarded as representative design goal of IPMSM.

A Evaluation of Emergency Braking Performance for Electro Mechanical Brake using Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기를 적용한 전기기계식 제동장치의 비상제동 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Joon-Hyuk;Kim, Seog-Won;Kim, Sang-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.170-177
    • /
    • 2020
  • This study examined the clamping force control method and the braking performance test results of an electromechanical brake (EMB) using braking test equipment. Most of the studies related to EMBs have been carried out in the automotive field, dealing mainly with the static test results for various control methods. On the other hand, this study performed a dynamic performance evaluation. The three-phase interior permanent magnet synchronous motor (IPMSM) was applied to drive the actuator of the EMB, and the analysis was verified by JMAG(Ver. 18.0), which is finite element method (FEM) software. The current control, speed control, and position control were used for clamping force control of the EMB, and the maximum torque per ampere (MTPA) control was applied to the current controller for efficient control. The EMB's emergency braking deceleration performance was tested in the same way as conventional pneumatic brake systems when the wheel of a train rotates at 110 km/h, 230 km/h, and 300 km/h. The emergency braking time, with the wheel stopped completely at the maximum rotational speed, was approximately 73 seconds. The similarity of the braking time and deceleration pattern was verified through a comparison with the performance test results of the pneumatic brake system applied to the next generation high-speed railway vehicle (HEMU-430X).

A MTPA Control Method for Sensorless V/f Operation of SPMSMs (SPMSM의 센서리스 V/f 운전 시 MTPA 제어 기법)

  • Kim, Won-Jae;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.240-246
    • /
    • 2018
  • In this paper, a sensorless V/f control based on maximum torque per ampere (MTPA) operation for PMSMs is proposed. Given that the MTPA operation is not considered in the conventional sensorless V/f control, efficient PMSM drives cannot be achieved. Therefore, this paper proposes an improved technique based on the d-axis current control to enable the MTPA operation in the V/f control for PMSMs. A stabilization technique is also proposed to improve the dynamic characteristics and stability against load variation. The effectiveness of the proposed technique is verified by conducting experiments with a 250 W SPMSM for driving a blower.

Simple Estimation Scheme for Initial Rotor Position and Inductances for Effective MTPA-Operation in Wind-Power Systems using an IPMSM

  • Kang, Yi-Kyu;Jeong, Hea-Gwang;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.396-404
    • /
    • 2010
  • This paper presents simple schemes used to estimate the initial rotor position and the d- and q-axis inductances for effective Maximum Torque per Ampere (MTPA) operation in a wind-power system using an IPMSM (Interior Permanent Magnet Synchronous Machine). An IPMSM essentially requires an exact coordinate transformation and accurate inductance values to use a reluctance torque caused by the saliency characteristic. In the proposed high-frequency voltage testing method, there is no voltage drop caused by the resistance and the electromotive force. The initial rotor position and the inductance can be measured through an analysis of the stator current without turning the rotor. The experimental results are presented in order to illustrate the feasibility of the proposed method.

Development of an 80[kW] IPMSM Drive System for an Electric Vehicle (전기자동차용 80[kW] IPMSM 구동 시스템 개발)

  • Kim, Sang-Hoon;Park, Nae-Chun
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.61-66
    • /
    • 2013
  • This paper is about the development of 80[kW] IPMSM(Interior Permanent Magnet Synchronous Motor) drive system for an electric vehicle. MTPA(Maximum Torque per Ampere) operation and flux-weakening operation for the optimal torque control of the IPMSM are presented. In this system, the torque control of the IPMSM is achieved by using the look-up table, which gives d- and q-aixs current references for the given torque command in the MTPA operation and flux-weakening operation regions. This look-up table is made by current injection tests, and from which the motor parameters are also estimated. The proposed system is verified by the experiment on the electric vehicle drive system, which consists of an 80[kW] IPMSM and an IGBT inverter.

  • PDF

Numerical Investigation on Permanent-Magnet Eddy Current Loss and Harmonic Iron Loss for PM Skewed IPMSM

  • Lim, Jin-Woo;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.417-422
    • /
    • 2011
  • This paper presents the characteristics of PM eddy current loss and harmonic iron loss for PM step-skewed Interior Permanent Magnet Synchronous Motor (IPMSM) with concentrated windings and multi-layered PM under the running condition of maximum torque per ampere (MTPA) and flux-weakening control. In particular, PM eddy current loss and harmonic iron loss in IPMSM have been numerically computed with three-dimensional Finite Element Analysis (3D FEA), whereby IPMSM with concentrated windings and multi-layered PM has been designed to identify the optimized skew angle contributing to the reduced PM eddy current loss and torque ripples, while maintaining the required average torque. Furthermore, numerical investigation on PM eddy current loss and iron loss at MTPA and flux-weakening control has been carried-out in terms of PM step-skew.