• 제목/요약/키워드: MTF measurement

검색결과 62건 처리시간 0.02초

HDTV용 CRT 프로젝션 광학엔진의 MTF 측정 연구MTF (measurement for optical engine of CRT rear projection HDTV)

  • Song, Jong-Sup;Lee, Ji-Young;Lee, Yun-Woo;Lee, Hoi-Youn;Lee, In-Won;Jo, Jae-Heung;Kim, Jin-Ho;Park, Sang-Kyung
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.34-35
    • /
    • 2002
  • Large-screen projectors for video applications and computer monitors are convenient instruments for conference presentations as well as for TV use at home. Recently, CRT and LCD projectors have achieved higher resolutions and luminance in the projection TV The large surface of the CRT compared to the LCD allows a great number of pixels to be displayed, while simultaneously providing maximum brightness of the final picture. (omitted)

  • PDF

회의실 유리창 진동음의 음성 명료도 분석 (Speech Intelligibility Analysis on the Vibration Sound of the Glass Window of a Conference Room)

  • 김희동;김윤호;김석현
    • 한국소음진동공학회논문집
    • /
    • 제17권4호
    • /
    • pp.363-369
    • /
    • 2007
  • The purpose of the study is to obtain acoustical information to prevent eavesdropping of the glass window. Speech intelligibility was investigated on the vibration sound detected from the glass window of a conference room. Objective test using speech transmission index(STI) was performed to estimate quantitatively the speech intelligibility. STI was determined based on tile modulation transfer function(MTF) of the room-glass window system. Using Maximum Length Sequency(MLS) signal as a sound source, impulse responses of the glass window and MTF were determined by signals from accelerometers and laser doppler vibrometer. Finally, speech intelligibility of the interior sound and window vibration were compared under different sound pressure levels and amplifier gains to confirm the effect of measurement condition on the speech intelligibility.

편심측정 결과가 반영된 몬테카를로 시뮬레이션을 이용한 적외선 광학계 조립정렬 공차 할당 기법 (Tolerance Allocation Method for IR Optics Fabrication Using Monte-Carlo Simulation Based on Measured Reflective Eccentricity)

  • 유재은
    • 한국광학회지
    • /
    • 제22권4호
    • /
    • pp.161-169
    • /
    • 2011
  • 본 논문에서는 광학 민감도가 큰 IR 광학계의 조립정렬과정에서 목표 성능을 만족시키기 위한 조립정렬 허용범위를 설정하는 방법을 제시하였다. 조립정렬 과정에서 편심측정기를 이용하여 각각의 광학소자에 대한 반사 편심량을 측정할 수 있다. 측정된 값을 이용하여 몬테카를로 시뮬레이션을 수행하였고 이를 이용하여 조립 정렬 이후의 광학계의 성능을 예측하였다. 시뮬레이션 결과와 실제 제작된 광학계의 광학 성능을 비교하여 본 논문에서 제시한 공차 할당 기법의 타당성을 확인하였다.

렌즈 평가를 위한 MTF 알고리즘 (HTF Algorithm for Evaluation of Lenses)

  • 송필재;이종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.403-406
    • /
    • 2006
  • Various cameras that is included digitial camera and portable individual terminal are supplied rapidly. Therefore, is trying for quality sophistication of camera that buy each camera manufacture. However, is selecting sample test way because there is no correct lens measurement method in mass production. This paper presents method to measure performance of lens to improve performance of camera. This paper presents method to measure performance of lens to improve performance of camera. As automation public prosecutor lens quality is correct and did quantification so that done measuring is possible. And processing designed possible MTF with high steed.

  • PDF

디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구 (Research for The Environmental Optimization of Dose and Image quality in Digital Radiography)

  • 이광재;김민기;이종웅;김호철
    • 전자공학회논문지
    • /
    • 제50권2호
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography(DR)는 film/screen(F/S)과 비교하여 넓은 계조와 높은 Detective Quantum Efficiency(DQE), Modulation Transfer function(MTF)를 바탕으로 화질의 개선과 저 선량으로 검사가 가능할 것으로 예상됐지만 기대와는 다르게 과노출이 Signal to Noise Ratio(SNR)향상을 가져 오면서 환자 피폭선량의 증가를 가져오게 되었으며 이는 Dose Creep이라는 개념으로 설명 된다. DR에서의 선량 증가 이유는 F/S의 촬영에서 사용했던 관전압(kVp)을 고정 적용하여 Auto Exposure Control(AEC)를 사용하기 때문에 과노출을 유발 할 수 있다. 이에 본 논문은 DR에서 적합한 일반촬영 방법을 제안하고자 관전압이 대조도에 주는 영향, 관전류(mA)변화에 따른 MTF 측정, 머리 모형을 촬영한 영상의 Peak Signal to Noise Ratio(PSNR) 측정을 통해 정량적 평가를 시행 하였다. 그 결과 관전압에 의한 대조도 변화는 후보정 이후 개선이 가능하며, 관전류에 의한 MTF 측정 결과 50%영역은 1.41~1.39 lp/mm, 10% 영역은 3.19~2.8 lp/mm로 관전류 변화에 따른 초점크기 변화는 영상의 해상력에 영향을 주지 않는다. 영상의 PSNR측정 결과는 관전압과 관전류가 증가 하여도 90kVp를 제외하고 30dB 이상으로 시각에 의한 영상의 차이를 인지하기 어렵다. 실험결과를 바탕으로 디지털 일반촬영에서 관전압은 80kVp 이상 100kVp이하, 관전류는 선예도와 상관 관계가 없으므로 선량과 조사시간을 단축 시킬 수 있는 방향으로 사용하기를 제안한다.

Measurement of Imaging Property of Flat-Panel Detector

  • Matsumoto, Masao;Suekane, Kouji;Maeda, Kouji;Ogata, Yuji;Inamura, Kiyonari;Kanai, Kouzo;Kanamori, Hitoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.385-388
    • /
    • 2002
  • We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curves, Modulation Transfer Function (MTF), Wiener spectra (WS), Noise Equivalent Quanta (NEQ) and Detective Quantum Efficiency (DQE)) for the direct type and indirect type of Flat-Panel Detector (FPD). First, the digital and overall characteristic curves of the both types of FPD had more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of the direct-type FPD were superior to those of the indirect-type FPD. Third, for identical exposures, the digital and overall WS of the direct-type FPD were similar or worse than those of the indirect-type FPD, and for larger exposure, the digital WS of the both types of FPD were smaller, but overall WS of the both types of FPD were larger. Fourth, the digital and overall NEQ and DQE of the direct-type FPD were worse than both NEQ and DQE of the indirect-type FPD at lower spatial frequencies, but were better at higher spatial frequencies.

  • PDF

변조전달함수 측정에 있어 기하학적 조정 불량이 해상도에 미치는 영향 (Effects of the Geometrical Misalignment on the MTF Measurement)

  • 김준우
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.705-713
    • /
    • 2021
  • 엑스선 영상 시스템으로부터 획득한 영상의 공간주파수에 대한 해상도를 분석하기 위해 변조전달함수(modulation-transfer function, MTF)를 계산한다. 일반적으로 검출기의 응답함수는 슬릿-카메라를 사용하여 선분포함수(line-spread function, LSF)를 획득하고, 푸리에 변환을 거쳐 변조전달함수를 도출한다. 엑스선이 항상 슬릿-카메라 중심에 입사해야 된다는 조건 때문에 실험자에 의해 발생하는 검출기와 슬릿-카메라의 기울임은 검출기 성능에 영향을 미치게 된다. 이와 더불어 기울임에 확대율이 더해진다면 엑스선 영상 시스템의 성능평가에 문제가 발생할 것이다. 본 연구에서는 실험적 오차에 기인하여 이를 변조전달함수, 즉 푸리에 도메인에서 실험과 분석모델을 해석하였고, 공간주파수에 미치는 영향을 분석하였다. 나아가 다양한 엑스선 영상 시스템에 있어 성능평가가 실시되어야 할 것이고, 실험적 오차는 불가결하게 발생하며 이를 허용할 수 있는 범위에 대한 검토가 이루어져야 한다.

시간에 따르는 CR장비의 영상의 질평가 (Measurement of Image Quality According to the Time of Computed Radiography System)

  • 손순룡;최관우;김정민;정회원;권경태;황선광;이익표;김기원;정재용;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.365-374
    • /
    • 2015
  • 진단의 높은 정확성을 유지하기 위하여 영상 품질의 정기적인 quality assurance (QA) 검사는 필수적이다. 이 연구의 목적은 2006년부터 2015년까지 시간에 따른 (2006, 2009, 2012, 2015) computed radiography (CR) system의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하여 평가 하는 것이다. 우리는 edge method를 이용하여 pre-sampled MTF를 구하였고 international electrotechnical commission standard IEC: 62220-1의 RQA5가 측정에 적용되었으며, X선관 초점으로부터 CR 표면까지의 거리는 150 cm이며, 부가필터 21 mmAl을 사용하였다. 관전압은 $72{\pm}2kVp$였으며 관전압을 1~2 kVp조절하여 HVL이 $7.1{\pm}1mmAl$되도록 하였다. 연구결과는 MTF의 공간주파수 50% ($mm^{-1}$)에서 사용 기간 별로 2006년은 1.54, 2009년은 1.14, 2012년은 1.12, 2015년은 1.38 이었고 공간주파수 10% ($mm^{-1}$)에서 사용 기간 별로 2006년은 2.68, 2009년은 2.44, 2012년은 2.44, 2015년은 2.46 이었다. 각각의 노이즈 분포는 2006년이 가장 낮은 노이즈 분포를 보였으며 2015, 2009, 2012 순으로 낮은 노이즈 분포를 나타내었다. Peak DQE와 $1mm^{-1}$에서도 2006년이 가장 우수한 DQE를 보였으며 2015년, 2009년, 2012년 순으로 DQE값을 나타내었다. 정확한 진단을 위하여 주기적인 CR 시스템의 유지보수가 필요하며 본 연구는 CR 시스템의 QA 및 수행성능 평가에 기초가 될 것으로 생각된다.

해상도 타겟을 이용한 무인항공영상의 품질 평가 (Quality Evaluation of UAV Images Using Resolution Target)

  • 이재원;성상민
    • 한국지리정보학회지
    • /
    • 제22권1호
    • /
    • pp.103-113
    • /
    • 2019
  • 공간해상도는 영상품질을 평가하는 매우 중요한 파라미터들 중의 하나이다. 본 연구에서는 무인 항공영상의 품질평가 방안의 일환으로 bar target과 Siemens star 도형을 이용하여 공간해상도와 MTF(Modulation Transfer Function)를 평가하는 방안을 제시하였다. 이를 위하여 고정익 eBee(Canon IXUS)로는 비행고도 130m와 260m로 촬영하고, 회전익 GD-800(SONY NEX-5N)으로는 130m, Phantom 4 pro(FC 6310)는 90m 고도에서 각각 촬영하여 정사영상을 제작하여 공간해상도를 측정하였다. 실험결과 공간해상도는 Siemens star와 Bar target 모두에서 카메라에 관계없이 정확히 비행고도에 비례하여 낮아짐을 알 수 있었다. 즉, 서로 상이한 카메라가 탑재된 Canon IXUS(eBee)와 SONY NEX-5N(GD-800)으로 130m의 동일 고도에서 촬영한 영상의 공간해상도는 4.1cm로 동일하였으며, eBee 260m의 경우에는 공간해상도가 8.0cm이었다. 아울러 Siemens star로 측정한 해상도가 Bar target에 비하여 모든 고도에서 1~2cm 가량 낮았다. 영상의 해상도와 명암 정보를 동시에 나타내는 MTF의 ${\sigma}_{MTF}$ 측정에서도 비행고도에 비례하는 일반적인 경향을 알 수 있었다. 하지만 130m 동일고도에서 SONY NEX-5N(GD-800)의 ${\sigma}_{MTF}$ 는 0.36이고, Canon IXUS(eBee)는 0.59로 카메라 성능이 더 좋은 SONY NEX-5N(GD-800)이 우수함을 알 수 있었다. 본 연구의 결과는 무인항공영상의 공간해상도 분석과 품질의 신뢰도 향상에 기여할 것으로 기대한다.