The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

MTM MEASUREMENT OF THE LENS ON THE KITSAT-1 EARTH IMAGING SYSTEM (우리별 인공위성의 지상 촬영 장치에 쓰여진 렌즈의 MTF 측정)

  • 류광선;민경욱;유상근
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.320-326
    • /
    • 1994
  • The KITSAT-1 (Auguse, 1992) and the KITSAT-2(September, 1993) were successfully launched and operated by the SatRec(Satellite Research Center). Both carry the CCD cameras to monitor the image of the earth. We used the camera bench type automatic equipment in the KSRI(Korea Standards Research Institute) to measure the MTF(Modulation Transfer Function) value of the lens attached to the CCD camera. We measured the tangential MTF and the sagital MTF by varing the f-number and the field angle. According to the result, the light from a point source is focused within one pixel of the CCD chip when the f-number is smaller than 4.0, and the MTF value becomes smaller as the field angle increases.

  • PDF

Evaluation of color CRT monitor by MTFA (MTFA에 의한 칼라 CRT의 화질 평가)

  • 김태희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The MTF(modulation transfer function) measuring system with a linear CCD(charge coupled-device) was constructed to cvaluate a color CRT(catode ray tube). The measured MTF values were corrected by considering the spectral response and the pixel sizes of CCD. The effects of a spot size, video bandwidth, pitch of shadow mask holes, display luminance, and ambient illumination on image quality were studied. The uniformity of resolution and the contrast Ioss by ambient light of the color CRT monitor were measured, and the results were analyzed by MTFA(modulation threshold area).

  • PDF

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.

A Study on Assessment of MTF Performance and Theoretical Analysis of Convex Trial Lenses (볼록 검안렌즈의 MTF 성능 분석 및 이론적 해석에 대한 연구)

  • Bang, Hyun Jin;Lee, Jong Ung;Son, Byung Ho;Ahn, Kyo Hoon;Choi, Eun Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.217-223
    • /
    • 2013
  • White light MTF(Modulation Transter Function)s of biconvex trial lenses from 10 to 20 diopter (D) were represented as a function of angular frequency and visual acuity, and then they were compared with AIM(Aerial Image Modulation) curves. All of the biconvex trial lenses evaluated in on-axis mode had MTF performance that could resolve Landolt's ring up to visual acuity 2.0. However, in a half field angle of five degrees, the trial lens of 10 diopters was able to resolve Landolt's ring up to visual acuity 0.9, and that of 20 diopter only up to visual acuity 0.8. This means that the trial lenses in the case of a half field angle of five degrees do not have sufficient resolution to measure visual acuity by 1.0.

CCD Scanning type MTF Measuring System for Microlens Arrays (CCD를 이용한 미세렌즈의 MTF 측정)

  • 이윤우;조현모;이인원;박태호;윤성균;서형원
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.364-371
    • /
    • 1994
  • Real-time MTF measuring system for testing microlens arrays with a linear CCD array is developed. The spread function of slit image that is relayed and magnified by a microscopic object lens can be measured at several times in a second. The signal uniformity and MTF of CCD is also calibrated. The experimental result of micro lens arrays developed for contact image sensor is presented.sented.

  • PDF

MTF comparision of CCD camera measured by two methods: Twyman-Green interferometer method and zoom lens method with three sinusoidal gratings (트와이만-그린 간섭계를 이용한 CCD의 MTF 값과 줌 렌즈를 이용한 CCD의 MTF 값 측정 비교.)

  • 홍성목;조재흥;임천석;이윤우;이회윤
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.28-29
    • /
    • 2003
  • 각종 렌즈 및 카메라, 망원경, 현미경 등 다양한 광학계들이 설계 및 개발 되고 있는 시점에서 그 성능을 정확하게 평가하는 것이 매우 중요하다. 광학계의 성능 평가를 위해서는 크게 정성적인 방법과 정량적인 방법으로 나눌 수 있는데, 정성적인 방법에 의한 평가는 분해능 표판이나 주기적인 격자의 상을 스크린 등에 결상시킨 후 사람의 눈을 통해서 한계 분해능을 평가하는 방법이다. 정량적인 방법에 의한 평가는 OTF(Optical Transfer Function)를 측정하거나 설계 자료를 통해 계산해 내는 것이다. (중략)

  • PDF

Image Quality Evaluation for the Railway Abrasion Measurement with a High Resolution (고해상도 레일 마모도 측정을 위한 영상 평가)

  • Ahn, Sung-Hyuk;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.887-894
    • /
    • 2009
  • There is no standard rule for the test of the railway abrasion measurement system composed of the line laser and the camera. This paper is proposed of the method to estimate the performance of the railway abrasion measurement system. The performance estimation is achieved by the quantitative analysis parameters such as MTF, NPS and DQE.

MTF Measuring Equipment of Optical System for LCD Substrate Inspection (LCD 기판 검사 광학계의 MTF 측정장치 제작)

  • Hong, Sung-Mok;Kim, Hee-Nam;Jo, Jae-Heung;Lee, Yun-Woo;Lee, Hoi-Youn;Yang, Ho-Soon;Lee, In-Won;Jung, Jin-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • We developed the equipment to measure the MTF(modulation transfer function) of an optical system for automatically inspecting the surface condition of an LCD substrate. We have made an object generator with USAF(United States Air Force) targets of three bar patterns and an integrating sphere, and an image analyzer with a 2 dimensional CCD(charge coupled device) and a relay lens. The MTF of the lens under test was obtained by correcting the measured CTF(contrast transfer function) which is the ratio of the contrast in the image of the USAF target to the contrast in the object. We have measured an optical system of F/13.65 (2.6x), the MTF are 30.6 % tangential plane and 26.1 % sagittal plane at 62.5 1p/mm.