• 제목/요약/키워드: MS solution

검색결과 509건 처리시간 0.025초

Studies on mycotoxins using LC-MS/MS for the forage produced in Incheon

  • Ra, Do Kyung;Choi, Jae Yeon;Lee, Ju Ho;Nam, Ji Hyun;Lee, Jeoung Gu;Lee, Sung Mo
    • 한국동물위생학회지
    • /
    • 제42권3호
    • /
    • pp.127-133
    • /
    • 2019
  • The purpose of this study was to investigate the contamination level of representative mycotoxins that have adverse effects on livestock by using LC-MS/MS method and to utilize the results as basic data for the establishment of quality control system for feed, and to provide information on production and storage. A total of nine mycotoxins, including aflatoxin $B_1$, aflatoxin $B_2$, aflatoxin $G_1$, aflatoxin $G_2$, ochratoxin A, fumonisin $B_1$, fumonisin $B_2$, deoxynivalenol (DON), zearalenone (ZEN) were simultaneously analyzed in LC-MS/MS under ESI positive mode. Fumonisin $B_1$ and fumonisin $B_2$ were detected from 3 cases of 75 forage produced in Incheon area, the detection rate was 4.0%. The detection concentration was 0.01~0.02 mg/kg, which was lower than the domestic recommended limit. Fumonisins were detected in a slightly different manner from the results of mycotoxin studies reported in Korea, which is attributed to the high temperature and dry summer weather of the year. The result of LC-MS/MS method performance of 9 mycotoxins, the recovery of DON was quite low as $41.53{\pm}3.91%$ that is not suitable for simultaneous analysis. This is probably due to that the extract solution used in this study was not suitable for the extraction of DON, along with the characteristics of a very dry forage. For the study of mycotoxins in Incheon area forage for the first time, further investigation is needed for the safe supply of livestock products.

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권5호
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

이동로봇의 장애물 회피기술 (A Technology of Obstacle Avoidance of Mobile Robot)

  • 오세봉;한성현
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.132-145
    • /
    • 2008
  • We propose a new technique for autonomous navigation and travelling of mobile robot based on ultrasonic sensors through the narrow labyrinth that leave only distance of a few centimeters on each side between the guides and the robot. In our current implementation the ultrasonic sensor system fires at a rate of 100 ms, that is, each of the 8 sensors fires once during each 100 ms interval. This is a very good firing rate, implemented here for optimal performance. This paper presents an extensively tested and verified solution to the problem of obstacle avoidance. Our solution is based on the optimal placement of ultrasonic sensors at strategic locations around the robot. Both the sensor location and the associated navigation algorithm are defined in such a way that only the accurate radial sonar data is used for accurate travelling.

오존산화공정에서 수산화라디칼(OH.)의 생성속도 측정 (The estimation of Hydroxyl radical generation rate in Ozonation)

  • 권충일;공성호;배성렬
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권1호
    • /
    • pp.3-12
    • /
    • 2001
  • 오존산화공정에서 수산화라디칼(OH.)의 생성속도가 다양한 실험조건(오존의 주입농도, 니트로벤젠의 농도, scavenger, pH, 과산화수소)에서 측정되었다. 니트로벤젠은 오존과의 직접적인 반응보다는 수산화라디칼에 의해 분해되었으며 분해속도는 오존과 니트로벤젠의 농도의 함수로 표현되었다. 또한 수산화라디칼 scavenger의 농도가 증가할수록 반응속도는 감소하였다. 실험상에서 얻은 모든 결과는 일차반응속도식을 따랐다. Probe compound와 scavenger를 이용한 경쟁적 방법을 사용하여 수산화라디칼을 측정하였는데, 그 결과 수산화라디칼의 생성속도는 오존의 농도에 선형적으로 비례하였으며, 오존 1몰당 수산화라디칼은 0.24몰이 생성되었다. 동일 오존농도에서 pH의 변화에 따른 수산화라디칼의 생성속도가 측정되었으며, (pH 10.2 ($0.91Ms^{-1}$) > pH 7.3($0.72Ms^{-1}$) > pH 5.6($0.67Ms^{-1}$) > pH 3.4($0.63Ms^{-1}$)) 중성이하의 pH에서보다 알칼리성 pH에서 수산화라디칼은 많이 발생됨을 알 수 있다. 또한 과산화수소의 첨가도 수산화라디칼의 생성속도를 증진시키는 결과를 낳았다. pH의 조절과 과산화수소의 첨가시 발생속도를 비교해보면 과산화수소를 첨가했을 때 수산화라디칼의 발생속도는 1.6배정도 더 크게 측정되었는데 이는 수산화라디칼을 발생시키는 데 있어서 과산화수소의 첨가가 pH의 조절보다는 더 좋은 증진제로써 작용할 수 있다는 것을 설명해준다. 이러한 결과들은 오염된 토양이나 지하수를 처리하기 위한 오존을 이용한 고급산화공정에 충분히 적용될 수 있을 것이라 판단된다.

  • PDF

다검출기 유도결합 플라즈마 질량분석기를 이용한 신속하고 정밀한 Pb 동위원소 분석 (Rapid and Precise Determination of Pb Isotope Ratios Using Mu1ti-Collector ICP/MS)

  • 최만식;정창식;신형선;임태선
    • 암석학회지
    • /
    • 제10권3호
    • /
    • pp.157-171
    • /
    • 2001
  • 다검출기 유도결합 플라즈마 질량분석기(Multi-Collector Inductively Coupled Plasma Mass Spectrometer; MC/ICP/MS; AXIOM MC 모델)를 이용한 Pb동위원소 분석 시 고려 사항인 Pb/Ti 비율, Pb농도 영향, 기질 원소 영향을 살펴보고, NBS 981 용액을 2001년 3월부터 8월까지 42번 측정하여 정확도 및 재현성 을 검토하였다. 그리고 암석, 청동기 및 퇴적물 시료의 Pb 동위원소를 분석하여 열 이온화 질량분석기(TIMS) 자료와 비교하였다. NBS 981 Pb 200 ng으로 동위원소 비율을 측정하였을 때 $^{206}$ $Pb^{204}$ , $Pb^{207}$ //$Pb^{204}$ , $Pb^{208}$ $Pb^{204}$ Pb 비율은 약 500 ppm(2sd), $^{/}$$207^{206}$ Pb 및 $Pb^{208}$ $Pb^{206}$Pb 비율은 100~200 ppm(2sd)의 재현성을 얻을 수 있었다. Pb등위원소 분석의 정확도 및 재현성 측면에서 최적 조건은 1) Pb/Tl농도 비가 10 이고 2) Pb농도가 100 ng/ml 이상이며 3) 질량 분별 효과는 지수 법칙에 따라 보정하고 이 때 사용된 Tl의 동위원소 비율($^{205}$ $Tl^{203}$ Tl)은 2.3887이며 질량 분별 인자는 측정된 $208^{Pb}$ $^{206}$$Pb^{205}$ $Tl^{203}$ Tl 비율로부터 경험적으로 구해진 Pb의 인자를 이용하는 것이었다. 시료 중의 기질 원소들(matrix elements)에 의한 Pb 동위원소 비율의 영향은 없는 것으로 판단되며, TIMS와 비교된 시료들에 대하여 Pb 등위원소들은 측정 오차 범위 내에서 잘 일치하였다. 즉, MC/ICP/MS에 의한 Pb 동위원소 분석은 시료 전처리 단계를 줄여도 WS와 유사한 정밀도를 얻을 수 있어 신속한 분석방법이라 할 수 있다.다.

  • PDF

천궁의 경정배양을 통한 기내번식 (In Vitro Propagation of Cindium officinale Makino Through Shoot Tip Culture)

  • 이현숙;정재동;김창배;윤재태;최부술
    • 식물조직배양학회지
    • /
    • 제21권4호
    • /
    • pp.221-225
    • /
    • 1994
  • 주요 약용작물로 사용하고 있는 천궁의 경정을 기내배양 하여 건전한 종경을 대량으로 증식하는데 적함한 배양조건을 구명하기 위하여 실험한 결과를 요약하면 7월에 채취한 재료를 1%의 NaOCI에 20분간 표면살균한 후, carbenicillin 500 mg/L, BA 1.0 mg/L 와 $GA_3$ 1.0 mg/L가 첨 가된 1/2 MS배지가 오염율 감소와 신초 재분화율을 높이는데 효과적이었고, 재분화한 신초의 기내증식은 BA 0.5 mg/L와 당 60 g/L가 함유된 1/2 MS가 양호하였으며 이들 유묘는 1/2 MS에 NAA 3.0 mg/L 단용배지에서 배양하였을때 발근하였다.

  • PDF

Analysis of Minor Additives and Polymer in Used-stripper Using Pyrolysis-Gas Chromatography/Mass Spectrometry and Electrospray Mass Spectrometry

  • Koo, Jeong-Boon;Park, Chang-Hyun;Han, Cheol;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권2호
    • /
    • pp.368-372
    • /
    • 2009
  • The trace polymer and additives in used stripper solutions were analyzed by a combination of Py-GC/MS and ESI-MS. In the comparison of the pyrolysates produced by the pyrolysis of the pure stripper and photoresist at $500{^{\circ}C}$, the presence of novolac polymer in the used stripper was confirmed by the presence of the characteristic peaks of its pyrolysates, such as those of the methylphenol, di-methylphenol and methylenebis(methylphenol) isomers. The intact trace polymer was measured by ESI-MS, which showed the distribution of oligomers at intervals of 120 Da, indicating di-methylphenol to be the repeat unit. Additional MS/MS measurements demonstrated that the end group is methylphenol and the repeat groups are di-methylphenol. Some modified oligomers caused by the methylation or di-methylation of the repeat unit were also identified. Although the polymer is only present at a trace level in the used stripper, these combined analytical methods provided the means to qualify the stripper solution through the identification and structural determination of the polymer.

상아질 지각과민 처치제의 임상적 효과에 대한 연구 (CLINICAL STUDY OF DESENSITIZER FOR TREATMENT OF DENTINAL HYPERSENSITIVITY)

  • 조경모;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.219-224
    • /
    • 2000
  • The purpose of this study is for evaluating the effect of MS Coat desensitizing agent in clinical situation. In this study total 60 teeth of 30 patients who is feeling hypersensitivity after periodontal surgery were treated with MS Coat desensitizing agent, and 20 teeth with saline solution for placebo effects and evaluated. All teeth were cleaned with rubber cup and pumice, after then the antibacterial agent was applied for 20 seconds and simply isolated using cotton roll Desensitizing agent was applied with a specific instrument in the manufacturers package by abrading motion for 10 seconds and re-done 8 times. Tactile stimulus with sharp explorer, air stimulus with syringe of dental unit, $7^{\circ}C$ cold water stimulus using micropipette applicator was done to evaluate hypersensitivity before apply test agent, immediate after application, 1 week after, and 3 month after application. The degree of hypersensitivity was recorded using 100mm Visual Analogue Scale and compared between group and evaluation times. From this clinical study sensitivity to the stimulus was significantly induced in both groups and MS Coat made a significant reduction in VAS score than placebo group did(p<.01). The results of this study could demonstrate that MS Coat desensitizing agent can use effectively to heat dentinal hypersensitivity.

  • PDF

Time Synchronization Error and Calibration in Integrated GPS/INS Systems

  • Ding, Weidong;Wang, Jinling;Li, Yong;Mumford, Peter;Rizos, Chris
    • ETRI Journal
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2008
  • The necessity for the precise time synchronization of measurement data from multiple sensors is widely recognized in the field of global positioning system/inertial navigation system (GPS/INS) integration. Having precise time synchronization is critical for achieving high data fusion performance. The limitations and advantages of various time synchronization scenarios and existing solutions are investigated in this paper. A criterion for evaluating synchronization accuracy requirements is derived on the basis of a comparison of the Kalman filter innovation series and the platform dynamics. An innovative time synchronization solution using a counter and two latching registers is proposed. The proposed solution has been implemented with off-the-shelf components and tested. The resolution and accuracy analysis shows that the proposed solution can achieve a time synchronization accuracy of 0.1 ms if INS can provide a hard-wired timing signal. A synchronization accuracy of 2 ms was achieved when the test system was used to synchronize a low-grade micro-electromechanical inertial measurement unit (IMU), which has only an RS-232 data output interface.

  • PDF

피부흡수 대체시험법의 조건설정을 통한 수용성, 지용성 물질의 투과 특성 연구 (A Permeation Characteristics Study of Water- or Oil-soluble Substances through Condition Setting for the In Vitro Skin Absorption Method)

  • 서지은;이진호;김배환
    • 한국환경보건학회지
    • /
    • 제43권1호
    • /
    • pp.77-86
    • /
    • 2017
  • Objectives: The purpose of this study was to compare permeation characteristics in three skin types using oil-soluble benzoic acid and water-soluble caffeine after method condition optimization based on OECD guideline 428. Methods: A Franz diffusion cell, a reliable alternative method for skin permeation, was used. One-milliliter samples were taken and immediately replaced with fresh solution in the receptor chamber at regular time intervals (1, 2, 4, 7, 10 and 24 hr). The amount of test substances was measured by LC-MS/MS. Results: The permeation rate increased dose-dependently, and the permeation orders were $KeraSkin^{TM}$ > hairless mouse full skin > human cadaver epidermis for skin types, and benzoic acid solution > caffeine solution > benzoic acid cream > caffeine cream for type of test materials. Conclusion: According to the definitions of Marzulli, benzoic acid and caffeine would be classified as 'fast' and 'moderate' compared with the permeation of other chemical species. The setting conditions and permeation characteristics performed in this study are expected to contribute to future permeation studies.