• 제목/요약/키워드: MS analysis

검색결과 3,878건 처리시간 0.031초

Quality Assessment of Curcuma longa L. by Gas Chromatography-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis

  • Li, Ming;Zhou, Xin;Zhao, Yang;Wang, Dao-Ping;Hu, Xiao-Na
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권10호
    • /
    • pp.2287-2293
    • /
    • 2009
  • Gas Chromatography-Mass Spectrometry (GC-MS) fingerprint analysis, Principle Components Analysis (PCA), and Hierarchical Cluster Analysis (HCA) were introduced for quality assessment of Curcuma longa L. (C. longa). The GC-MS fingerprint method was developed and validated by analyzing 33 batches of samples of C. longa from different geographic locations. 18 chromatographic peaks were selected as characteristic peaks and their relative peak areas (RPA) were calculated for quantitative expression. Two principal components (PCs) were extracted by PCA. C. longa collected from Guizhou and Fujian were separated from other samples by PC1, capturing 71.83% of variance. While, PC2 contributed for their further separation, capturing 11.13% of variance. HCA confirmed the result of PCA analysis. Therefore, GC-MS fingerprint study with chemometric techniques provides a very flexible and reliable method for quality assessment of C. longa.

GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS)

  • 김진영;김종상;김민경;이재일;서용준;인문교
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

Basics of Ion Mobility Mass Spectrometry

  • Lee, Jong Wha
    • Mass Spectrometry Letters
    • /
    • 제8권4호
    • /
    • pp.79-89
    • /
    • 2017
  • Ion mobility mass spectrometry (IM-MS) combines the advantages of ion mobility spectrometry (IMS) and MS for effective gas-phase ion analysis. Separation of ions based on their mobilities prior to MS can be performed without a great loss in other analytical figures of merit, and the extra dimension of analysis offered by IM can be beneficial for isomer and complex sample analyses. In this review, basic principles of IMS and IM-MS are described in addition to an introduction to various IMS techniques and commercial IM-MS instruments. The nature of collision cross-section (${\Omega}_D$), an important parameter determining the transport properties of ions in IMS, is also explained in detail.

GC-MS에 의한 옥수수 미숙종자의 Brassinosteroid 동정 (Identification of Brassinosteroids in Immature seeds of Zea mays by GC-MS analysis)

  • 김선재;;박근형
    • Applied Biological Chemistry
    • /
    • 제38권2호
    • /
    • pp.179-183
    • /
    • 1995
  • 옥수수미숙종자에 함유된 brassinosteroid활성물질을 탐색하고자 MeOH추출물에서 얻어진 brassinosteroid활성물질을 정제, 분획하여 GC-MS로 분석한 결과, castasterone, teasterone, 28-norcastasterone, 6-deoxocastasterone 등의 4종의 brassinosteroid가 옥수수종자로부터 최초로 동정되었다.

  • PDF

In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교 (Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro)

  • 이인희;김유현
    • 대한임상검사과학회지
    • /
    • 제47권4호
    • /
    • pp.306-312
    • /
    • 2015
  • 알러지 반응이 일어나면 histamine이 방출되기 때문에 histamine을 정량 측정함으로써 유발된 알러지의 정도를 확인 할 수 있다. 일반적으로는 항원-항체반응으로 microplate reader를 이용하여 흡광도를 측정하여 정량 한다. 본 연구에서는 histamine 방출량을 측정함에 있어서 일반적인 항원-항체반응과 분석 화학적인 방법으로 HPLC-MS를 이용한 방법을 비교하였다. 세포주는 RBL-2H3를 사용하였고, C48/80으로 자극시켜 알러지를 유발하였다. 유발된 알러지는 ${\beta}$-hexosaminidase의 측정으로 탈 과립을 확인하였으며 실험의 정당성을 위하여 세포독성 능을 확인하였다. Histamine 정량에서 항원-항체반응에 의한 측정의 정량한계는 10.257 ppm이었고, HPLC-MS에 의한 정량한계는 0.020 ppm으로 현저한 차이를 보였다. 알러지 활성 및 항 알러지 실험에 있어서 histamine의 측정은 HPLC-MS를 이용한 분석이 더 정밀하고 정확한 실험인 것을 확인하였다.

LC/MS/MS를 이용한 비글견의 혈장 중 Doxifluridine 및 5-Fluorouracil의 동시 분석법 Validation (Validation of a Selective Method for Simultaneous Determination of Doxifluridine and 5-Fluorouracil in Dog Plasma by LC-MS/MS)

  • 김기환;김원;김진성;김경일;강원구;이종화;하정헌;정은주
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.179-186
    • /
    • 2007
  • A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.

LC/MS/MS를 이용한 가바펜틴 300 mg 캡슐의 성인 지원자에 대한 생물학적 동등성 및 약물동태 연구 (Bioequivalence and Pharmacokinetic study of Gabapentin 300mg Capsules using Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) in Volunteers)

  • 정지훈;권준택;윤휘열;강원구;권광일
    • 한국임상약학회지
    • /
    • 제16권1호
    • /
    • pp.63-68
    • /
    • 2006
  • Gabapentin, 1-(aminomethyl-1-cyclohexyl)acetic acid, is anew antiepileptic drug related to ${\gamma}-aminobutyric$ acid(GABA) currently being introduced in therapy worldwide. The bioavailability and pharmacokinetics of gabapentin capsules were examined in 22 volunteers who received a single oral dose in the fasting state by randomized balanced $2{\times}2$ crossover design. After dosing, blood samples were collected for a period of 24 hours and analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS). Time course of plasma gabapentin concentration was analyzed with non-compartmental and compartmental approaches. $WinNonlin^{(R)}$, the kinetic computer program, was used for compartmental analysis. One compartment model with first-order input, first-order output with no lag time and weighting by $1/(predieted\;y)^2$ was chosen as the most appropriate pharmacokinetic model for the volunteers. The major pharmacokinetic parameters $(AUC_{0-24hr},\;AUC_{inf},\;C_{max}\;and\;T_{max})$ and other parameters $(K_a,\;K_{el},\;V_d/F\;and\;Cl/F)$ of $Gapentin^{TM}$ (test drug) and $Neurontin^{TM}$ (reference drug) were estimated by non-compartmental analysis and compartmental analysis. The 90% confidence intervals of mean difference of logarithmic transformed $AUC_{0-24hr}\;and\;C_{max}$ were $log(0.9106){\sim}log(1.l254)\;and\;log(0.8521){\sim}log(1.0505)$, respectively. It shows that the bioavailability of the test drug is equivalent with that of the reference drug. There was no statistically significant difference between the two drugs in all pharmacokinetic parameters.

  • PDF

Ethyl Acetate와 Methanol을 이용한 블루베리 추출물 대사체 분석 (Metabolomic Analysis of Ethyl Acetate and Methanol Extracts of Blueberry)

  • 조영희;김수경;권다애;이홍진;최형균;어중혁
    • 한국식품영양과학회지
    • /
    • 제43권3호
    • /
    • pp.419-424
    • /
    • 2014
  • 본 연구에서는 LC-MS/MS를 이용한 블루베리의 methanol과 ethyl acetate 추출 분획에 존재하는 대사체의 분석을 통해 효율적인 대사체 profiling의 가능성을 탐색하였다. LC-MS/MS에서 검출되는 대사체를 통계 처리한 결과, methanol 추출 분획에서는 5-O-feruloylquinic acid, malvidin hexoside, malvidin-3-arabinoside, petunidin-3-arabinoside, delphinidin hexoside, delphinidin, petunidin hexoside와 같은 안토시아닌 계열의 화합물들이 존재하였고, ethyl acetate 분획에서는 chlorogenic acid, chlorogenic acid dimer, 6,8-di-C-arabinopyranosylluteolin, luteolin과 같은 플라보노이드 계열의 화합물이 검출되었다. 본 연구는 기존 연구와 달리 대사체학 기법을 이용한 블루베리 추출물 전체 대사물질의 profiling을 시도한 최초의 연구로서 블루베리에 함유된 유용 성분의 스크리닝 등 향후 응용 연구에 유용한 기반으로 이용될 수 있을 것으로 기대된다.

Comparative Proteomic Analyses of the Yeast Saccharomyces cerevisiae KNU5377 Strain Against Menadione-Induced Oxidative Stress

  • Kim, Il-Sup;Yun, Hae-Sun;Jin, In-Gnyol
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.207-217
    • /
    • 2007
  • The Saccharomyces0 cerevisiae KNU5377 strain, which was isolated from spoilage in nature, has the ability to convert biomass to alcohol at high temperatures and it can resist against various stresses [18, 19]. In order to understand the defense mechanisms of the KNU5377 strain under menadione (MD) as oxidative stress, we used several techniques for study: peptide mass fingerprinting (PMF) by matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry (MS) followed by two-dimensional (2D) gel electrophoresis, liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), and surface-enhanced laser desorption ionization-time of flight (SELDI-TOF) technology. Among the 35 proteins identified by MALDI-TOF MS, 19 proteins including Sod1p, Sod2p, Tsa1p, and Ahp1p were induced under stress condition, while 16 proteins were augmented under normal condition. In particular, five proteins, Sod1p, Sod2p, Ahp1p, Rib3p, Yaf9p, and Mnt1p, were induced in only stressed cells. By LC-ESI-MS/MS analysis, 37 proteins were identified in normal cells and 49 proteins were confirmed in the stressed cells. Among the identified proteins, 32 proteins were found in both cells. Five proteins including Yel047cp and Met6p were only upregulated in the normal cells, whereas 17 proteins including Abp1P and Sam1p were elevated in the stressed cells. It was interesting that highly hypothetical proteins such as Ynl281wp, Ygr279cp, Ypl273wp, Ykl133cp, and Ykr074wp were only expressed in the stressed cells. SELDI-TOF analysis using the SAX2 and WCX2 chips showed that highly multiple-specific protein patterns were reproducibly detected in ranges from 2.9 to 27.0 kDa both under normal and stress conditions. Therefore, induction of antioxidant proteins, hypothetical proteins, and low molecular weight proteins were revealed by different proteomic techniques. These results suggest that comparative analyses using proteomics might contribute to elucidate the defense mechanisms of KNU5377 under MD stress.

Analysis and Exposure Assessment of Perchlorate in Korean Dairy Products with LC-MS/MS

  • Oh, Sung-Hee;Lee, Ji-Woo;Mandy, Pawlas;Oh, Jeong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.12.1-12.7
    • /
    • 2011
  • Objectives: Perchlorate is an emerging contaminant that is found everywhere, including various foods. Perchlorate is known to disturb the production of thyroid hormones and leads to mental disorders in fetuses and infants, as well as metabolic problems in adults. In this study, we attempted to establish an LC-MS/MS method for measuring perchlorate in dairy products and used this developed method to investigate perchlorate levels in Korean milk and yogurt samples. Methods: The developed method of perchlorate analysis requires a shaker and 1% acetic acid/acetonitrile as the extracting solvent. Briefly, the samples were extracted and then centrifuged (4000 rpm, 1hour), and the supernatant was then passed through a $Envi^{TM}$ Carb SPE cartridge that had been prewashed sequentially with 6 mL of acetonitrile and 6 mL of 1% acetic acid in water. The final volume of the sample extract was adjusted to 40 mL with reagent water and the final sample was filtered through a 0.20-${\mu}m$ pore size PTFE (Polytetrafluoroethylene) syringe filter prior to LC-MS/MS. Results: The average levels of perchlorate in milk and yogurt samples were $5.63{\pm}3.49\;{\mu}g/L$ and $3.65{\pm}2.42\;{\mu}g/L$, respectively. The perchlorate levels observed in milk samples in this study were similar to those reported from China, Japan, and the United States. Conclusions: The exposure of Koreans to perchlorate through the consumption of dairy products was calculated based on the results of this study. For all age groups, the calculated exposure to perchlorate was below the reference of dose (0.7 ${\mu}g/kg$-day) proposed by the National Academy of Science, USA, but the perchlorate exposure of children was higher than that of adults. Therefore, further investigation of perchlorate in other food samples is needed to enable a more exact assessment of exposure of children to perchlorate.