• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.023 seconds

MRI-Guided Gadolinium Neutron Capture Therapy

  • Ji-Ae Park;Jung Young Kim;Hee-Kyung Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.113-118
    • /
    • 2022
  • Gadolinium neutron capture therapy (Gd-NCT) is a precision radiation therapy that kills cancer cells using the neutron capture reaction that occurs when 157Gd hits thermal neutrons. 157Gd has the highest thermal neutron capture cross section of 254,000 barns among stable isotopes in the periodic table. Another stable isotope, 155Gd, also has a high thermal neutron trapping area (~ 60,700 barns), so gadolinium that exists in nature can be used as a Gd-NCT drug. Gd-NCT is a mixed kinetic energy of low-energy and high-energy ionizing particles, which can be uniformly distributed throughout the tumor tissue, thereby solving the disadvantage of heterogeneous dose distribution in tumor tissue. The Gd complexes of small-sized molecule are widely used as contrast agents for magnetic resonance imaging (MRI) in clinical practice. Therefore, these compounds can be used not only for diagnosis but also therapy when considering the concept of Gd-NCT. This multifunctional trial can look forward to new medical advance into NCT clinical practices. In this review, we introduce gadolinium compounds suitable for Gd-NCT and describe the necessity of image guided Gd-NCT.

Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils (6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.699-706
    • /
    • 2018
  • In this study, we measured signal intensities according to array coil position changes to provide reference data of coil directions and the distances as it deters image quality unless the coils are aligned properly. The multi-purpose MRI phantom was placed in body array coils, and it was moved to the top, bottom, left, and right directions by 2 cm from the center to 10 cm. After obtaining images, signal intensities were measured and compared. The results of this study were as follows: Except for the upward direction, the signal intensities of the reference signal was not significantly different from that of the reference signal intensity within 2cm in both T1 and T2-weighted images. In conclusion, in clinical circumstances which various challenges exist to align the coils exactly on the same lines, array coils should be positioned at least within 2 cm from the center except for the upward direction, on the same line to prevent the image qualities are lowered.

Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI (고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발)

  • Lee, Hong-Seok;Woo, Dong-Cheol;Min, Kwang-Hong;Kim, Yong-Kwon;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • Purpose : The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. Materials and Methods : Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm, thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. Results : SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. Conclusion : The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.

  • PDF

Clinical Usefulness of I-123 MIBG Scintigraphy with Early Planar and SPECT Image in The Diagnosis of Neuroendocrine Tumors (신경내분비종양 진단에 있어서 I-123 MIBG 조기 평면 영상과 SPECT 영상의 임상적 유용성)

  • Shin, Jung-Woo;Ryu, Jin-Sook;Won, Kyoung-Sook;Choi, Yun-Young;Kim, Hee-Jung;Yang, Seoung-Oh;Lee, Hee-Kyung;Suh, Yong-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.516-523
    • /
    • 1996
  • The purpose of this study was to evaluate the clinical usefulness of I-123 MIBG scintigraphy with early planar and SPECT image in the diagnosis of neuroendocrine tumors. We reviewed I-123 MIBG scintigraphies of 21 patients who had been suspected to have neuroendocrine tumors by CT or MRI findings. Early 4 hour planar and SPECT images were obtained in all patients and delayed (13-24 hour) planar images were performed in 17 patients. Final diagnoses were made by surgery, biopsy, or clinical follow up. Twelve patients were confirmed to have neuroendocrine tumors. With 4 hour planar and SPECT images, there were 9 true positives(6 pheochromocytomas, 1 paraganglioma, 1 neuroblastoma, and 1 medullary cancer of the thyroid), 8 true negatives(1 adrenal cortical adenoma, 1 malignant fibrous histiocytoma, 1 adenoma in colon and 5 benign nonfunctioning adrenal tumors), 1 false positive(hepatocellular carcinoma) and 3 false negatives(1 recurred medullary cancer of the thyroid, 1 liver metastasis of carcinoid tumor and 1 ganglioneuroma). The sensitivity and specificity of I-123 MIBG scintigraphy were 75% and 89%, respectively. SPECT images provided good anatomical correlation with CT or MRI. Delayed images showed increased tumor to background ratio in 5 out of 8 true positive patients, but did not change the diagnosis. In conclusion, early 4 hour images with I-123 MIBG is clinically convenient and useful method in the detection of neuroendocrine tumors, and SPECT images can provide good anatomical correlation with CT or MRI.

  • PDF

Brain MRI Template-Driven Medical Images Mapping Method Based on Semantic Features for Ischemic Stroke (허혈성 뇌졸중을 위한 뇌 자기공명영상의 의미적 특징 기반 템플릿 중심 의료 영상 매핑 기법)

  • Park, Ye-Seul;Lee, Meeyeon;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.2
    • /
    • pp.69-78
    • /
    • 2016
  • Ischemic stroke is a disease that the brain tissues cannot function by reducing blood flow due to thrombosis or embolisms. Due to the nature of the disease, it is most important to identify the status of cerebral vessel and the medical images are necessarily used for its diagnosis. Among many indicators, brain MRI is most widely utilized because experts can effectively obtain the semantic information such as cerebral anatomy aiding the diagnosis with it. However, in case of emergency diseases like ischemic stroke, even though a intelligent system is required for supporting the prompt diagnosis and treatment, the current systems have some difficulties to provide the information of medical images intuitively. In other words, as the current systems have managed the medical images based on the basic meta-data such as image name, ID and so on, they cannot consider semantic information inherent in medical images. Therefore, in this paper, to provide core information like cerebral anatomy contained in brain MRI, we suggest a template-driven medical images mapping method. The key idea of the method is defining the mapping characteristics between anatomic feature and representative images by using template images that can be representative of the whole brain MRI image set and revealing the semantic relations that only medical experts can check between images. With our method, it will be possible to manage the medical images based on semantic.

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

Prior to Breast MRI Guidelines in Korea, Where Were We?

  • Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.35-42
    • /
    • 2021
  • Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.

Quantitative Analysis of Modified Fermi-Direc Filter applied to Clinical MR Image (임상 MR영상에 적용된 변형 Fermi-Direc필터의 정량적 평가)

  • Kim, Ki-Hong;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.225-230
    • /
    • 2009
  • Filtering has been used to improve the image quality not only in MRI but in most image processing fields. In this paper, modified Fermi-Direc filter was transformed in various shapes, and then the optimum shape was designed. In addition, Newly made filter was applied in real clinic, which showed the obvious improvement in image quality. In conclusion, filtered image was superior to original image in contrast and sharpness. Then, this was proved by the histogram of R, G, B channel used for the quantitative analysis.

Multimodal Medical Image Registration based on Image Sub-division and Bi-linear Transformation Interpolation (영상의 영역 분할과 이중선형 보간행렬을 이용한 멀티모달 의료 영상의 정합)

  • Kim, Yang-Wook;Park, Jun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.34-40
    • /
    • 2009
  • Transforms including translation and rotation are required for registering two or more images. In medical applications, different registration methods have been applied depending on the structures: for rigid bodies such as bone structures, affine transformation was widely used. In most previous research, a single transform was used for registering the whole images, which resulted in low registration accuracy especially when the degree of deformation was high between two images. In this paper, a novel registration method is introduced which is based image sub-division and bilinear interpolation of transformations. The proposed method enhanced the registration accuracy by 40% comparing with Trimmed ICP for registering color and MRI images.