• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.025 seconds

Gradient Waveform Synthesizer in Magnetic Resonance Imaging System using Digital Signal Processors (DSP를 이용한 자기공명영상시스템의 경사자계 파형 발생기)

  • Go, Gwang-Hyeok;Gwon, Ui-Seok;Kim, Chi-Yeong;Kim, Hyu-Jeong;Kim, Sang-Muk;An, Chang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In this paper, we develop a TMS320C31 (60MHz) digital signal processor (DSP) board to synthesize gradient waveforms for Spiral Scan Imaging (SSI), which is one of the ultra fast magnetic resonance imaging (MRI) methods widely used. In SSI, accurate gradient waveforms are very essential to high quality magnetic resonance images. For this purpose, sampling rate for synthesizing the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP boards accurate gradient waveforms are obtained. Ultra fast spiral scan imaging with the developed with the developed DSP board is currently under development.

  • PDF

Morphological variation of the velum in children and adults using magnetic resonance imaging

  • Kotlarek, Katelyn J.;Haenssler, Abigail E.;Hildebrand, Kori E.;Perry, Jamie L.
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.153-158
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate variations in velar shape according to age, sex, and race using magnetic resonance imaging (MRI). Materials and Methods: The study sample consisted of 170 participants (85 children, 85 adults) between 4 and 34 years of age. Velar morphology was visually classified using midsagittal MRI scans for each participant by 2 independent raters. Inter- and intra-rater reliability was assessed. Statistical analyses were performed to identify correlations of velar shape with sex, age, and race. Results: The most frequent velar shape was "butt" for both adults(41%) and children (58%) in this study. The least common shapes for adults were "leaf" and "S." The children did not exhibit any "leaf" or "straight" velar shapes. A statistically significant difference was noted for age with respect to velar shape (P=0.014). Sex and race were found to have no significant impact on velar shape in this study. Conclusion: When using MRI to evaluate velar morphology, the "butt" shape was most common in both children and adults. Velar shape varied significantly with age, while race and sex did not have a significant impact.

Fascicular Involvement of the Median Nerve Trunk in the Upper Arm: Manifestation as Anterior Interosseous Nerve Syndrome With Unique Imaging Features

  • Jae Eun Park;Darryl B. Sneag;Yun Sun Choi;Sung Hoon Oh;SeongJu Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.449-458
    • /
    • 2024
  • Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.

Current Landscape and Future Perspectives of Abbreviated MRI for Hepatocellular Carcinoma Surveillance

  • Hyo Jung, Park;Nieun Seo;So Yeon Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.598-614
    • /
    • 2022
  • While ultrasound (US) is considered an important tool for hepatocellular carcinoma (HCC) surveillance, it has limited sensitivity for detecting early-stage HCC. Abbreviated MRI (AMRI) has recently gained popularity owing to better sensitivity in its detection of early-stage HCC than US, while also minimizing the time and cost in comparison to complete contrast-enhanced MRI, as AMRI includes only a few essential sequences tailored for detecting HCC. Currently, three AMRI protocols exist, namely gadoxetic acid-enhanced hepatobiliary-phase AMRI, dynamic contrast-enhanced AMRI, and non-enhanced AMRI. In this study, we discussed the rationale and technical details of AMRI techniques for achieving optimal surveillance performance. The strengths, weaknesses, and current issues of each AMRI protocol were also elucidated. Moreover, we scrutinized previously performed AMRI studies regarding clinical and technical factors. Reporting and recall strategies were discussed while considering the differences in AMRI protocols. A risk-stratified approach for the target population should be taken to maximize the benefits of AMRI and the cost-effectiveness should be considered. In the era of multiple HCC surveillance tools, patients need to be fully informed about their choices for better adherence to a surveillance program.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

Brain Perfusion SPECT Imaging in Sturge-Weber Syndrome: Comparison with MR Imaging (Sturge-Weber 증후군의 뇌관류 SPECT 영상: 자기공명영상과의 비교)

  • Ryu, Jin-Sook;Choi, Yun-Young;Moon, Dae-Hyuk;Yang, Seoung-Oh;Ko, Tae-Sung;Yoo, Shi-Joon;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.56-64
    • /
    • 1996
  • The purpose of this study was to evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. $^{99m}Tc$-HMPAO or $^{99m}Tc$-ECD interictal brain SPECTs were performed on 5 pediatric patients with Sturge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Sturge-Weber syndrome.

  • PDF

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

Analysis on Ischemic Cerebrovascular of Middle Age and Oldest-Old Age by Using Magnetic Resonance Imaging (자기공명영상을 이용한 중년 및 초고령의 허혈성 뇌혈관 호발 부위에 대한 분석)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.391-396
    • /
    • 2012
  • The purpose of this study was to present basic research data to utilize magnetic resonance imaging (MRI) with analyzing intracerebral regional distributions of ischemic cerebrovascular disease of middle aged and oldest-old aged people. We retrospectively analyzed middle-aged group (average age of 44.2 year-old, 43 males, 26 females) and oldest-old aged group (average age of 84.7 year-old, 58 males, 71 females) who taken MRI screening for ischemic cerebrovascular disease from May 2006 year to January 2008 year. The intracerebral vascular were classified into 8 vessels, which anterior communication artery (ACoA), posterior communication artery (PCoA), anterior cerebral artery (ACA), middle cerebral artery (MCA), posterior cerebral artery (PCA), internal carotid artery (ICA), common carotid artery(CCA), and basilar artery (BA). The result of middle-aged group showed that more ischemic cerebrovascular diseases appeared in men than women, and it affected in MCA mostly. In oldest-old aged group, ischemic cerebrovascular diseases occurred evenly spaced in intracerebral region of right, left, and both vessels, and women have more than men. For men, the most occurred in ICA and for women the most occurred in MCA. Specially middle-aged group in men showed that more ischemic cerebrovascular diseases in MCA appeared than oldest-old aged group in men. It is suggested that the analysis on ischemic cerebrovascular could be helpful in the clinical diagnosis and treatment.

Design and Implementation of Microstrip Quadrature Coupler and High Power Transmitting/Receiving Switch Using Dynamic Loading Technique for 1-Tesal MRI System (동적 부하 기술을 이용한 1-Tesla 자기공명 영상 시스템용 마이크로 스트립 quadrature coupler 및 고출력 송수신 스위치의 설계 및 제작)

  • 류웅환;이미영;이흥규;이황수;김정호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.1-11
    • /
    • 1999
  • It is now common practice to utilize the quadrature RF coils to improve the signal-to-noise ratio (SNR) in the Magnetic Resonance Imaging (MRI) System. In addition, to make such an available SNR improvement, it is mandatory to use a well-designed quadrature coupler, which facilitates a perfect 3-dB coupling and quadrature-phase shift. However, the four ports matching condition has to be well considered during the RF excitation and the signal detection period. This work investigates the effects of such a mismatching condition (especially, due to patient) from the analysis, simulation, and real implementation and firstly proposes dynamic loading technique for a quadrature coupler and transmitting/receiving switch module to minimize a patient mismatching and enhance a system reliability. Also, we designed and implemented the quadrature coupler and transmitting/receiving switch module using microstrip. As a result, the SNR of our MRI system using the microstrip quadrature coupler and transmitting/receiving switch module with dynamic load increases 3 dB compared with the old one using USA quadrature switch. Also, the power capability of quadrature coupler and transmitting/receiving switch module is 5-kw peak power. Considering power loss and reduction of size, we used a RT/duroid 6010 substrate with high permittivity and for simulation we use Compact Software.

  • PDF

Automatic Left Ventricle Segmentation Algorithm using K-mean Clustering and Graph Searching on Cardiac MRI (K-평균 클러스터링과 그래프 탐색을 통한 심장 자기공명영상의 좌심실 자동분할 알고리즘)

  • Jo, Hyun-Wu;Lee, Hae-Yeoun
    • The KIPS Transactions:PartB
    • /
    • v.18B no.2
    • /
    • pp.57-66
    • /
    • 2011
  • To prevent cardiac diseases, quantifying cardiac function is important in routine clinical practice by analyzing blood volume and ejection fraction. These works have been manually performed and hence it requires computational costs and varies depending on the operator. In this paper, an automatic left ventricle segmentation algorithm is presented to segment left ventricle on cardiac magnetic resonance images. After coil sensitivity of MRI images is compensated, a K-mean clustering scheme is applied to segment blood area. A graph searching scheme is employed to correct the segmentation error from coil distortions and noises. Using cardiac MRI images from 38 subjects, the presented algorithm is performed to calculate blood volume and ejection fraction and compared with those of manual contouring by experts and GE MASS software. Based on the results, the presented algorithm achieves the average accuracy of 6.2mL${\pm}$5.6, 2.9mL${\pm}$3.0 and 2.1%${\pm}$1.5 in diastolic phase, systolic phase and ejection fraction, respectively. Moreover, the presented algorithm minimizes user intervention rates which was critical to automatize algorithms in previous researches.