• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.025 seconds

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Cortical Dysplasia: Tc-99m ECD SPECT Findings and Comparative Study with MRI according to Pathologic Grading (뇌피질 이형성증: Tc-99m ECD SPECT 소견과 병리적 등급에 따른 MRI와 비교 연구)

  • Park, Soon-Ah;Lim, Seok-Tae;Sohn, Myung-Hee;Chung, Gyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.23-32
    • /
    • 2001
  • Purpose: Cortical dysplasia (CD) designates a diverse group of malformations resulting from one or more abnormalities in the development of the cerebral cortex. We investigated the findings of interictal SPECT and the diagnostic usefulness of interical and ictal SFECT according to pathological grading (PG) in comparison with MRI. Materials and Methods: This study included 16 patients (M:F=9:7, age: $19.9{\pm}11.8$ yrs) with pathologically proven CD. Tc-99m ECD SPECT was performed in all patients: interictal 11, interictal and ictal 3, ictal 2. MRI were obtained in all patients and image analysis was done blindly as to the result of SPECT. Pathologic findings of CD were classified into grade 1 G1, dyslamination), grade 2 (G2, dysplastic neurons) and grade 3 (G3, balloon cells). We compared SFECT with MRI in lesions-to-lesions and analyzed the result according to PG. Results: In SFECT and MRI. 38 and 27 lesions were visually recognized. In 14 interictal SPECT, variable findings in 35 lesions were demonstrated: 25 were hypoperfusion, 7 hyperperfusion, 2 heterotopic perfusion in the white matter. By comparison between two studios, missed lesions were founded: SPECT were 1 lesion, MRI 12. Review of missed 12 lesions of MRI were followed according to PG: G1 patients were 16.7% (4/19), G2 40.0% (6/15), and G3 50% (2/4). Conclusion: Interictal SFECT in CD showed variable findings such as hypoperfusion, hyperperfusion or heterotopic perfusion. However, for detection of missed CD on MRI, SFECT may help to detect a functional abnormality of the lesion with high PG.

  • PDF

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

Automatic segmentation of magnetic resonance images using error back-propagation algorithm (오류 역전파 알고리즘을 이용한 자기 공명 영상 자동 세그멘테이션)

  • 최재호;조범준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.11
    • /
    • pp.2425-2431
    • /
    • 1997
  • The increased usage of Magnetic Resonance Image (MRI) required the method for automatic segmentation of medical image that is more useful so as to diagnose the dissecitive information of a atient quickly and effectively through MR scans.The use of neural networks may give much hep to solving the complex problems concerned the matter. This paper proposes the new method for automatic segmentation of magnetic resonance (MR) images of the brain by using neural networks brained by back-propagation algorithm. The trained neural networks by the segmenting MR images of a patient produce an output that networks can segment MR images of the other patients automatically, too and show a clear image of the brain.

  • PDF

Improved Sampling Method For Volume Rendering (Volume Rendering를 위한 향상된 Sampling 방법)

  • 박재영;이병일;최흥국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.213-216
    • /
    • 2000
  • 본 논문에서는 volume rendering 기법을 이용하여 2차원 MRI 영상들을 합성하여 3차원 영상 만들 때 보다 해상도를 높이기 위한 개선된 sampling방법을 소개한다 2차원 슬라이스 영상들이 3차원으로 재구성할 때 voxel 기반으로 렌더링을 하기 때문에 오브젝트의 내부 영역까지도 볼 수 있는 것이 volume rendering의 가장 큰 장점이다. 따라서 영상을 재구성하는 과정에서 보다 향상된 interpolation을 적용시켜서 공간 해상도를 향상시키면 보다 명확하게 오브젝트 내부 정보를 살펴 볼 수 있다. 본 논문에서는 nearest neighbor 이나 linear 같은 interpolation으로 sampling한 방법보다 cubic interpolation을 3차원 공간에서 적용 시켜서 보다 resampling이 잘 되도록 하여 해상도를 향상시켜 보았다. 이렇게 향상된 Interpolation 적용시켜서 렌더링할 때 얼마나 오브젝트 내부 영역이 잘 가시화가 되었는지 transfer function을 적용시켜서 오브젝트 내부 정보를 렌더링 해보았고, 임의의 축으로 오브젝트을 잘라서 2D 단면 영상으로 출력해 보았다. 보다 향상된 interpolation을 적용시켜서 resampling을 하면 영상 해상도가 개선되었음을 볼 수 있었다.

  • PDF

A Study of Histogram of Oriented Gradients Feature Vector Based on Support Vector Machine for Medical Image Classification (의료 이미지 분류를 위한 서포트 벡터 머신 기반의 Histogram of Oriented Gradients 특징 벡터 연구)

  • Lee, SeungHwan;Yoo, JaeChern
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.5-6
    • /
    • 2020
  • 현대 의학에서 의료 영상은 수많은 영상처리 의료기기의 핵심이다. PACS(Picture Archiving Communication System)를 통해 관리되는 의료 영상 자료들은 요청에 따라 저장, 검색 및 전송을 수행하여 신속한 의료 서비스를 가능하게 한다. 그러나 만약에 관리자의 실수로 의료 영상 데이터가 바뀐다면 이는 사용자로 하여금 불편함과 낮은 신뢰성을 야기한다. 그리하여 본 논문에서는 서포트 벡터 머신 기반의 HOG(Histogram of Oriented Gradients) 특징 벡터를 이용하여 X-ray와 MRI(Magnetic Resonance Imaging) 사진을 분류하고 의료 영상 분류의 가능성을 제시하는 것을 목표로 한다.

  • PDF

Diffusion-Weighted Imaging for Detecting Glufosinate Ammonium Intoxication: A Case Report (글루포시네이트 암모늄 중독 환자의 확산자기공명영상 소견: 증례 보고)

  • Hyoung Yeob Kim;Noh Hyuk Park
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1354-1359
    • /
    • 2022
  • Glufosinate ammonium-containing herbicides are non-selective herbicides, used worldwide. With the increasing use of glufosinate ammonium-containing herbicides, cases of acute intoxication in suicide attempts have also increased. Herein, we report a case of a patient presenting cytotoxic edema in the posterior limbs of the bilateral internal capsules, bilateral middle cerebellar peduncles, and splenium of the corpus callosum on the brain diffusion-weighted MRI after glufosinate ammonium intoxication.

Diffuse Hemangiomatosis in the Intra-Abdominal Cavity Mimicking Peritoneal Metastasis: A Case Report (복강 내 전이와 유사한 복강 내 생긴 해면 혈관종증: 증례 보고)

  • Won Ik Ahn;Ji Yeol Shin;Ju Wan Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1182-1188
    • /
    • 2022
  • We call hemangiomatosis if hemangioma arises multifocally from single or multiple organs. It develops predominantly on liver, and there are just few cases of hemangiomatosis from greater omentum and mesentery. Herein, we present the imaging and histopathological findings including CT and MRI images of a 62-year-old male patient with a hemangiomatosis on liver, greater omentum and mesentery.