• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.029 seconds

Vital Signs Investigation in Subjects Undergoing Magnetic Resonance Imaging (자기공명검사 시 활력 징후의 변화)

  • Jeong, Mi-Ae;Choi, Kwan-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.412-417
    • /
    • 2019
  • This study was proposed to investigate vital signs in subjects undergoing high magnetic field (3T) MR imaging for provide basic data on causes of claustrophobia as few previous studies were conducted on this special issue. Vital signs of 104 patients were monitored before and during the clinically indicated MR examinations to identify any relationship between MR scanning and the vital signs. An increase of systolic, diastolic blood pressure and pulse pressure were observed. However, they were not statistically significant(p>0.05), which meant the vital signs measured before and during the MRI scanning showed no significant change. This study is considered to be meaningful basic data for analyzing the links between vital sign fluctuations on claustrophobia during routine clinical MR examinations.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

The Magnetic Resonance Images and Clinical Features of the Asymptomatic Pineal Cysts (무증상 송과체 낭종의 임상적 양상 및 자기공명영상 소견)

  • Lim, Kang-Taek;Park, Se-Hyuck;Shin, Dong-Ik;Cho, Byung Moon;Oh, Sae Moon;Hwang, Do Yun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.113-117
    • /
    • 2000
  • Objective : Asymptomatic cyst of the pineal gland is a common incidental finding in adults on computerized tomography or magnetic resonance image(MRI) or at postmortem examination. This study was conducted to identify MRI findings of the benign pineal cysts and to determine the proper management of asymptomatic pineal cysts. Methods : From January 1995 to March 1999, 13 cases of asymptomatic pineal cysts were diagnosed incidentally on MRI. The mean age of the patients at diagnosis was 43 years(ranged 8 to 69 years). Five patients were females and eight patients were males. We analyzed the clinical presentations and MRI findings. Results : Clincal features were not related to pineal cysts in all 13 cases included posttraumatic headache in seven cases, headache related to brain tumor in two cases, one of facial palsy, one of diabetic neuropathy, and two of other diseases. MRI demonstrated a well-demarcated mass lesion(mean 1.3cm in diameter) of low signal intensity on T1-weighted images and high signal intensity on T2-weighted images. Gadolinium-enhanced MRI, performed in 10 cases, demonstrated a rim enhancement. Hydrocephalus was not present in all cases. Follow-up MRI(ranged 12 to 36 months) obtained in 3 of the 13 patients showed stability of cyst size. After symptomatic treatment, presenting symptoms were resolved in all patients and symptom related to pineal cysts have not been developed during follow up period(mean 27 months). Conclusion : The long-term behavior of asymptomatic pineal cysts is still unknown. But we advocate conservative management of these benign pineal cysts that may be developmental variants of normal pineal gland.

  • PDF

Contribution of Lateral Ankle Instability Evaluation with MRI to Proximal Fifth Metatarsal Fracture (제5 중족골 근위부 골절 환자의 자기공명영상 검사를 통한 족관절 외측 불안정성 평가의 기여도)

  • Yoo, Jong-Min;Chu, In-Tak;Lee, Kyu-Jo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.119-122
    • /
    • 2010
  • Purpose: One of the main contributors to proximal fifth metatarsal fracture is ankle inversion and the incidence of recurrence may increase in patients with ankle instability. So, the authors confirmed the patients of proximal fifth metatarsal fracture with ankle instability by checking the history and magnetic resonance imaging (MRI) and assessed the value of MRI as therapeutic prognosis and clinical indicators for prevention of recurrence. Materials and Methods: Patients with proximal fifth metatarsal fractures visited our hospital during recent five years were reviewed. 35 patients with suspected damage by ankle inversion had been identified a history of ankle instability and checked the hindfoot malalignment through hindfoot alignment view and MRI was performed prospectively. The patients was devided to three groups on the location of fracture site and the groups were compared each other. Results: The mean time from injury to checking MRI was 10.7 days. There was no structural abnormality and was no significant difference according to the location of fracture. The patients with history of ankle inversion were 31(88.6%) and the patients with history of chronic or recurrent injury were 22 patients (62.9%). The lesion of MRI related to lateral ankle instability were identified in all patients. Conclusion: This study noted a high incidence of lateral ankle instability that was identified by MRI in the patients of proximal fifth metatarsal fracture. Aggressive treatment for lateral ankle instability should be needed for complications as proximal fifth metatarsal fracture to reduce the recurrence and occurrence.

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Prediction of Tumor Progression During Neoadjuvant Chemotherapy and Survival Outcome in Patients With Triple-Negative Breast Cancer

  • Heera Yoen;Soo-Yeon Kim;Dae-Won Lee;Han-Byoel Lee;Nariya Cho
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.626-639
    • /
    • 2023
  • Objective: To investigate the association of clinical, pathologic, and magnetic resonance imaging (MRI) variables with progressive disease (PD) during neoadjuvant chemotherapy (NAC) and distant metastasis-free survival (DMFS) in patients with triple-negative breast cancer (TNBC). Materials and Methods: This single-center retrospective study included 252 women with TNBC who underwent NAC between 2010 and 2019. Clinical, pathologic, and treatment data were collected. Two radiologists analyzed the pre-NAC MRI. After random allocation to the development and validation sets in a 2:1 ratio, we developed models to predict PD and DMFS using logistic regression and Cox proportional hazard regression, respectively, and validated them. Results: Among the 252 patients (age, 48.3 ± 10.7 years; 168 in the development set; 84 in the validation set), PD was occurred in 17 patients and 9 patients in the development and validation sets, respectively. In the clinical-pathologic-MRI model, the metaplastic histology (odds ratio [OR], 8.0; P = 0.032), Ki-67 index (OR, 1.02; P = 0.044), and subcutaneous edema (OR, 30.6; P = 0.004) were independently associated with PD in the development set. The clinical-pathologic-MRI model showed a higher area under the receiver-operating characteristic curve (AUC) than the clinical-pathologic model (AUC: 0.69 vs. 0.54; P = 0.017) for predicting PD in the validation set. Distant metastases occurred in 49 patients and 18 patients in the development and validation sets, respectively. Residual disease in both the breast and lymph nodes (hazard ratio [HR], 6.0; P = 0.005) and the presence of lymphovascular invasion (HR, 3.3; P < 0.001) were independently associated with DMFS. The model consisting of these pathologic variables showed a Harrell's C-index of 0.86 in the validation set. Conclusion: The clinical-pathologic-MRI model, which considered subcutaneous edema observed using MRI, performed better than the clinical-pathologic model for predicting PD. However, MRI did not independently contribute to the prediction of DMFS.

Additional Value of Integrated 18F-FDG PET/MRI for Evaluating Biliary Tract Cancer: Comparison with Contrast-Enhanced CT

  • Jeongin Yoo;Jeong Min Lee;Jeong Hee Yoon;Ijin Joo;Dong Ho Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.714-724
    • /
    • 2021
  • Objective: To evaluate the value of 18F-fluorodeoxyglucose PET/MRI added to contrast-enhanced CT (CECT) in initial staging, assessment of resectability, and postoperative follow-up of biliary tract cancer. Materials and Methods: This retrospective study included 100 patients (initial workup [n = 65] and postoperative follow-up [n = 35]) who had undergone PET/MRI and CECT for bile duct or gallbladder lesions between January 2013 and March 2020. Two radiologists independently reviewed the CECT imaging set and CECT plus PET/MRI set to determine the likelihood of malignancy, local and overall resectability, and distant metastasis in the initial workup group, and local recurrence and distant metastasis in the follow-up group. Diagnostic performances of the two imaging sets were compared using clinical-surgical-pathologic findings as standards of reference. Results: The diagnostic performance of CECT significantly improved after the addition of PET/MRI for liver metastasis (area under the receiver operating characteristic curve [Az]: 0.77 vs. 0.91 [p = 0.027] for reviewer 1; 0.76 vs. 0.92 [p = 0.021] for reviewer 2), lymph node metastasis (0.73 vs. 0.92 [p = 0.004]; 0.81 vs. 0.92 [p = 0.023]), and overall resectability (0.79 vs. 0.92 [p = 0.007]; 0.82 vs. 0.94 [p = 0.021]) in the initial workup group. In the follow-up group, the diagnostic performance of CECT plus PET/MRI was significantly higher than that of CECT imaging for local recurrence (0.81 vs. 1.00 [p = 0.029]; 0.82 vs. 0.94 [p = 0.045]). Conclusion: PET/MRI may add value to CECT in patients with biliary tract cancer both in the initial workup for staging and determination of overall resectability and in follow-up for local recurrence.

Dynamic Contrast Enhanced MRI and Intravoxel Incoherent Motion to Identify Molecular Subtypes of Breast Cancer with Different Vascular Normalization Gene Expression

  • Wan-Chen Tsai;Kai-Ming Chang;Kuo-Jang Kao
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1021-1033
    • /
    • 2021
  • Objective: To assess the expression of vascular normalization genes in different molecular subtypes of breast cancer and to determine whether molecular subtypes with a higher vascular normalization gene expression can be identified using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI). Materials and Methods: This prospective study evaluated 306 female (mean age ± standard deviation, 50 ± 10 years), recruited between January 2014 and August 2017, who had de novo breast cancer larger than 1 cm in diameter (308 tumors). DCE MRI followed by IVIM DWI studies using 11 different b-values (0 to 1200 s/mm2) were performed on a 1.5T MRI system. The Tofts model and segmented biexponential IVIM analysis were used. For each tumor, the molecular subtype (according to six [I-VI] subtypes and PAM50 subtypes), expression profile of genes for vascular normalization, pericytes, and normal vascular signatures were determined using freshly frozen tissue. Statistical associations between imaging parameters and molecular subtypes were examined using logistic regression or linear regression with a significance level of p = 0.05. Results: Breast cancer subtypes III and VI and PAM50 subtypes luminal A and normal-like exhibited a higher expression of genes for vascular normalization, pericyte markers, and normal vessel function signature (p < 0.001 for all) compared to other subtypes. Subtypes III and VI and PAM50 subtypes luminal A and normal-like, versus the remaining subtypes, showed significant associations with Ktrans, kep, vp, and IAUGCBN90 on DEC MRI, with relatively smaller values in the former. The subtype grouping was significantly associated with D, with relatively less restricted diffusion in subtypes III and VI and PAM50 subtypes luminal A and normal-like. Conclusion: DCE MRI and IVIM parameters may identify molecular subtypes of breast cancers with a different vascular normalization gene expression.

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.

Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System (자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석)

  • Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4891-4895
    • /
    • 2010
  • RF coil is an important component of the Magnetic Resonance Imaging (MRI) system and the performance of RF coil is one of major factors for high SNR images. Sensitivity and RF field uniformity are parameters for evaluating RF coil performance. Since the B1 field is induced by RF coil, MR signal is strongly affected by RF coil structure and arrangement. In receiving MR signal, the RF coil sensitivity to MR Signal is also determined by the induced B1 field of RF coil. Therefore, the spatial distribution of B1 field must be verified. In this work, we performed computer simulation of the basic RF coil structures using Matlab and verified their sensitivity and uniformity through their B1 field distribution. This work will be useful for the advanced multi-channel RF coil design.