• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.026 seconds

Three-Dimensional Printed Model of Partial Anomalous Pulmonary Venous Return with Biatrial Connection (양측 심방 연결을 형성하는 부분 폐정맥 환류 이상의 3D 프린팅 모델)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Sung-A Chang;Tae-Gook Jun;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1523-1528
    • /
    • 2020
  • Partial anomalous pulmonary venous return (PAPVR) is a rare congenital cardiac anomaly that can be difficult to detect and often remains undiagnosed. PAPVR is diagnosed using non-invasive imaging techniques such as echocardiography, CT, and MRI. Image data are reviewed on a 2-dimensional (D) monitor, which may not facilitate a good understanding of the complex 3D heart structure. In recent years, 3D printing technology, which allows the creation of physical cardiac models using source image datasets obtained from cardiac CT or MRI, has been increasingly used in the medical field. We report a case involving a 3D-printed model of PAPVR with a biatrial connection. This model demonstrated separate drainages of the right upper and middle pulmonary veins into the lower superior vena cava (SVC) and the junction between the SVC and the right atrium, respectively, with biatrial communication through the right middle pulmonary vein.

A Study of Optimal SOAmin for Motor and Language Tasks in Event-related fMRI using Stochastic Design (통계학적 자극설계를 이용한 Event-related fMRl에서 운동과 언어과제의 최적 SOAmin에 대한 연구)

  • 문찬홍;유재욱;나동규;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.28-34
    • /
    • 2002
  • Purpose : The minimum stimulus onset asynchronoy(SOAmin) is one of important experimental parameters for an event-related fMRI experiment designed with the stochastic stimulus. In this study, the most efficient SOAmin is explored for the stronger activation in motor and language tasks with the stimulus designed stochastically. Materials and methods : The event-related fMRI during motor and language tasks were obtained in four normal right-handed subjects. EPI-BOLD sequence is used at 1.5Tesla MR system for the acquisition of event-related fMRI. For each task the subjects are responded for the stimulus' with 2, 3, 4, and 6 seconds SOAmin. The obtained images are processed with SPM99, and the p value is set as 0.05 for the significant activation detection. The Z value and the number of activated pixels are compared for each task. Results : For the motor task, the primary and supplementary motor areas are activated, and for the language task the consistent activated signals are detected in the Broca's. The activated signal is to be stronger for the shorter SOAmin for both motor and language tasks. At primary motor area, the activated signals is the strongest for 3 seconds SOAmin and for the supplementary motor area the result with 2 seconds SOAmin shows the strongest activation. And the result of language task shows the strongest activation at the 2 seconds SOAmin. Conclusion : In the event-related fMRI of motor and language tasks with the stochastically designed stimulus, the 2 or 3 seconds SOAmin is efficient for more activated and clustered activation.

  • PDF

Understanding the Pathophysiology and Magnetic Resonance Imaging of Multiple Sclerosis and Neuromyelitis Optica Spectrum Disorders

  • Laura Cacciaguerra;Maria A. Rocca;Massimo Filippi
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1260-1283
    • /
    • 2023
  • Magnetic resonance imaging (MRI) has been extensively applied in the study of multiple sclerosis (MS), substantially contributing to diagnosis, differential diagnosis, and disease monitoring. MRI studies have significantly contributed to the understanding of MS through the characterization of typical radiological features and their clinical or prognostic implications using conventional MRI pulse sequences and further with the application of advanced imaging techniques sensitive to microstructural damage. Interpretation of results has often been validated by MRI-pathology studies. However, the application of MRI techniques in the study of neuromyelitis optica spectrum disorders (NMOSD) remains an emerging field, and MRI studies have focused on radiological correlates of NMOSD and its pathophysiology to aid in diagnosis, improve monitoring, and identify relevant prognostic factors. In this review, we discuss the main contributions of MRI to the understanding of MS and NMOSD, focusing on the most novel discoveries to clarify differences in the pathophysiology of focal inflammation initiation and perpetuation, involvement of normal-appearing tissue, potential entry routes of pathogenic elements into the CNS, and existence of primary or secondary mechanisms of neurodegeneration.

VALIDITY OF CLINICAL, TRANSCRANIAL RADIOGRAPHIC AND MAGNETIC RESONANCE IMAGING METHOD IN THE DIAGNOSIS OF INTERNAL DERANGEMENT OF TEMPOROMANDIBULAR JOINT (악관절장애 환자의 임상 및 측사위경두개 촬영에 의한 진단과 자기공명영상에 의한 진단의 비교연구)

  • Choi Jeong Hee;Chung Hyun Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.327-336
    • /
    • 1991
  • The purpose of this study was to evaluate the validity among the clinical, transcraial radiographic and MRI diagnosis in internal derangement of the temporomandibular joint. Fourty two temporomandibular joints were assessed in twenty one patients who visited the dental department of Chonnam National University Hospital with the complaint of temporomandibular disorder from Oct. 1990 to Oct. 1991. The results were as follows: 1. In the clinically symptomatic 29 TMJs, 26 (89.7%) joints reveal disc displacement and 3 (10.3%) joints reveal normal disc position on MRI. The sensitivity of clinical diagnosis was 0.77, and the specificity was 0.63. 2. In the normal 22 TMJs on the trans cranial radiographic finding, 16 (72.7%) joints reveal disc displacement, and 6 (27.3%) joints reveal normal disc position on MRI. In the abnormal 20 TMJs on the transcranial radiographic finding, 18 (90%) joints reveal disc displacement, and 2 (10%) joints reveal normal disc position on MRI. The sensitivity of trans cranial radio- graph was 0.53, and the specificity was 0.75.

  • PDF

Detecting Deception Using Neuroscience : A Review on Lie Detection Using Functional Magnetic Resonance Imaging (거짓 탐지와 뇌과학 : 기능적 자기공명영상을 활용한 거짓 탐지)

  • Choi, Yera;Kim, Sangjoon;Do, Hyein;Shin, Kyung-Shik;Kim, Jieun E.
    • Korean Journal of Biological Psychiatry
    • /
    • v.22 no.3
    • /
    • pp.109-112
    • /
    • 2015
  • Since the early 2000s, there has been a continued interest in lie detection using functional magnetic resonance imaging (fMRI) in neuroscience and forensic sciences, as well as in newly emerging fields including neuroethics and neurolaw. Related fMRI studies have revealed converging evidence that brain regions including the prefrontal cortex, anterior cingulate cortex, parietal cortex, and anterior insula are associated with deceptive behavior. However, fMRI-based lie detection has thus far not been generally accepted as evidence in court, as methodological shortcomings, generalizability issues, and ethical and legal concerns are yet to be resolved. In the present review, we aim to illustrate these achievements and limitations of fMRI-based lie detection.

Development and evaluation of MR compatible patch antenna for hyperthermia (온열치료를 위한 MR호환 평판가열안테나 개발 및 성능평가)

  • Kim, D.H.;Chun, S.I.;Jang, M.Y.;Yoon, M.S.;Kim, Y.B.;Jung, B.D.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.17-21
    • /
    • 2009
  • The thermal treatment have been combined with MRI which is able to acquire both an anatomical image with high-contrast and a thermal image, and have recently used for removing the tumor effectively. This study is to make a patch antenna which is designed to operate at 2.45GHz that has compatibility with MRI. The characteristic and specific absorption rate(SAR) were confirmed using computer simulation and confirmed a possibility of hyperthermia by performing experiment.

  • PDF

Usefulness of Functional MRI for the study of concentration sheet (Functional MRI를 이용한 학습집중력 향상 시트 개발)

  • Kim, Chang-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.13-17
    • /
    • 2009
  • In this thesis, we made a sheet to improve the concentration of study. To demonstrate the improvement in the concentration of study, we obtained functional magnetic resonance imaging (fMRI), which has superior time resolution and measures brain noninvasively by using intrinsic contrast agent. As a result of Brainwave measurement, we could verify the blood flow's activate in the nearby frontal lobe related to memory process and noticeable ratio change in absolute alpha wave and beta wave after the analysis of Brainwave measurement. fMRI ascertains the physiological function of the brain and is being used to prevent the trouble medically that can be caused before and after the operation. For the visibility of cranial nerve network, many researches will be carried out to develope the product which is related to brain like concentration of study.

  • PDF

Analysis of Claustrophobia in MRI Exam Among The Korea Auxiliary Police and Combat Auxiliary Police (전·의경 MRI 폐소공포증에 대한 분석)

  • Jeon, Woo-Jin;Jeong, Jae-Kyo;Chun, Sung-Joon;Yoon, Dae-Hyun;Lim, Yoon-Sik;Seok, Jong-Min
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.21-25
    • /
    • 2014
  • This study, was conducted to find out the correlation factors of anxiety of the patients during MRI exam on the claustrophobia. This study conducted a survey targeting those korea auxiliary police and combat auxiliary police patients who were admitted to the National Police Hospital over a period from January 2 to December 24, 2013 to investigate their degree of claustrophobia. In study result, sufficient explain before exam was helpful and decrease anxiety. However, they felt more anxious about limited spare, and when the entered a bore. Symptoms of instability and fear were stuffy, sweat, dyspnea, palpitation those are ascending rank of frequency.

  • PDF

The Evaluation of Optimized Inversion-Recovery Fat-Suppression Techniques for T2-Weighted Abdominal MR Imaging : Preliminary report (복부의 T2강조 영상에서 지방소거기법의최적의 평가)

  • Lee, Da-Hee;Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-35
    • /
    • 2012
  • To test the real image quality of a spectral attenuated inversion-recovery (SPAIR) fat-suppression (FS) techniquein clinical abdominal MRI by comparison to turbo spin echo inversion-recovery (TSEIR) fat-suppression (FS) technique. 3.0T MRI studies of the abdomen were performed in 30 patients with liver lesions (hemangiomas n: 15; HCC n: 15). T2W sequences were acquired using SPAIR TSEIR. Measurements included retroperitoneal and mesenteric fat signal-to-noise (SNR) to evaluate FS; liver lesion contrast-to-noise (CNR) to evaluate bulk water signal recovery effects; and bowel wall delineation to evaluate susceptibility and physiological motion effects. SPAIR-TSEIR images produce significantly improved FS and liver lesion CNR. The mean SNR of the retroperitoneal and mesenteric fat for SPAIR were 20.5, 10.2 and TSEIR were 43.2, 24.1 (P<0.05). SPAIR-TSEIR images produced higher CNR for both hemangiomas CNR 164.88 vs 126.83 (P<0.05) and metastasis CNR 75.27 vs 53.19 (P<0.05). Bowel wall visualization was significantly improved using in both SPAIR-TSEIR (P< 0.05). The real image quality of SPAIR was better than over conventional TSEIR FS on clinical abdominal MRI scans.

  • PDF

The Frequency Effect in the Somatosensory Cortex Response to Vibrotactile Stimulator in fMRI (기능적 자기공명영상에서 진동자의 자극 주파수가 감각피질의 반응에 미치는 영향)

  • Lee Hyunsook
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.128-133
    • /
    • 2004
  • The fMRI response of the somatosensory cortex was investigated with vibrotactile stimulation. Three different frequencies of 8, 15, or 25 Hz were applied in order to mainly focus on the hemodynamic response of Meissner corpuscles sensitive to frequencies of 5-40 Hz. A closed-system, pneumatically-driven, rubber diaphragm was fabricated that overcame many of the limitations of existing vibrotactile devices and produced robust sensory cortex activation in an fMRI experiment. Increasing frequency vs. activation area was analyzed in terms of signal percent change and number of pixels. Our preliminary results indicated that the distribution of the signal percentage change widened and more activated pixels were obtained with higher frequencies.

  • PDF