• Title/Summary/Keyword: MRI 영상

Search Result 1,907, Processing Time 0.035 seconds

Popliteal Artery Entrapment Syndrome -One case report - (슬와동맥 포착증후군 - 1예 보고 -)

  • Oh Jae-Yun;Lee Seock-Yeol;Lee Chol-Sae;Lee Seung-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.791-794
    • /
    • 2006
  • Popliteal artery entrapment syndrome is a rare disorder and lead to claudication and disturbance of blood flow from the results of an abnormal relationship of the popliteal artery to the gastrocnemius muscle, a fibrous band or the popliteus muscle in a young male population. The specific diagnosis is difficult, In most cases, surgical treatment provides a definitive diagnosis of the lesion and is necessary for the patient's recovery. A 34-years-old male was admitted complaining of claudication and pain on left leg. Ankle-brachial index, vascular sonography, CT-angiogram and MRI revealed an occlusion of proximal popliteal artery of left leg. The patient was confirmed as a popliteal artery entrapment syndrome (type IV) that the popliteal artery was entrapped by a fibrous band around the popliteus muscle in the operative fold. Completely occluded fibrotic popliteal artery was removed, and interposition with ipsilateral greater saphenous vein graft was done. After surgery, symptoms of the patient have improved.

Primary Malignant Melanoma of Lung -A case report- (원발성 폐 악성 흑색종 -1예 보고-)

  • Jeong, Young-Kyun;Lee, Eung-Bae;Park, Jae-Yong
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.76-79
    • /
    • 2006
  • Primary malignant melanoma of the lung is extremely rare. A 46-year-old lady was admitted with two month history of dry cough and blood-tinged sputum. Chest CT showed 4.5 $\times$ 5.0 cm sized mass at the right lower lobe. Repeated bronchoscopic and percutaneous biopsies showed no definite diagnosis. Preoperative evaluations revealed no systemic metastais. So, we tried the surgical approach. Right lower lobectomy and lymph node dissection was done. The mass and lymph node were confirmed as primary malignant melanoma. The patient presented with right hemiparesis 40 days after operation. Brain MRI showed 1.5$\times$2.0 cm sized mass lesion on the left parietal lobe. Mass excision was done. However, she expired 8 months later.

Development of 3D Modeling Technology of Human Vacancy for Bio-CAD (Bio-CAD를 위한 인체공동부의 3차원 모델링 기술 개발)

  • Kim, Ho-Chan;Bae, Yong-Hwan;Kwon, Ki-Su;Seo, Tae-Won;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.138-145
    • /
    • 2009
  • Custom medical treatment is being widely adapted to lots of medical applications. A technology for 3D modeling is strongly required to fabricate medical implants for individual patient. Needs on true 3D CAD data of a patient is strongly required for tissue engineering and human body simulations. Medical imaging devices show human inner section and 3D volume rendering images of human organs. CT or MRI is one of the popular imaging devices for that use. However, those image data is not sufficient to use for medical fabrication or simulation. This paper mainly deals how to generate 3D geometry data from those medical images. A new image processing technology is introduced to reconstruct 3D geometry of a human body vacancy from the medical images. Then a surface geometry data is reconstructed by using Marching cube algorithm. Resulting CAD data is a custom 3D geometry data of human vacancy. This paper introduces a novel 3D reconstruction process and shows some typical examples with implemented software.

Two Cases of Avascular Necrosis of the Femur Head after Whole Pelvic Radiation Therapy for the Treatment of Cervical Cancer (자궁경부암의 전골반방사선치료 후 발생한 대퇴골두 무혈성괴사 2예)

  • Yu, Jeong-Il;Huh, Seung-Jae;Park, Won;Oh, Dong-Ryul;Lee, Jung-Ae
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.126-130
    • /
    • 2008
  • Avascular necrosis(AVN) is a disease characterized by the temporary or permanent loss of the blood supply to the bones, resulting from many possible causes, including radiation therapy. The femoral head is known to be the most common site of AVN. The authors encountered two cases of AVN of the femoral head among 557 patients with cervical cancer treated with whole pelvic radiation therapy at the Samsung Medical Center. AVN of the femoral head was presented with a sclerotic density change in a plain roentgenography and a decreased signal intensity lesion on the T1 and T2 weighted phases of a magnetic resonance image(MRI). Although it is a very rare complication after whole pelvic radiation therapy, AVN of the femoral head should be considered when characteristic imaging findings appear on follow-up examinations.

$^{18}$F-Fluoride-PET in Skeletal Imaging ($^{18}$F-Fluoride-PET을 이용한 골격계 영상)

  • Jeon, Tae-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.253-258
    • /
    • 2009
  • Bone scintigraphy using $^{99m}$Tc-labeled phosphate agents has long been the standard evaluation method for whole skeletal system. However, recent shortage of $^{99m}$Tc supply and advanced positron emission tomography (PET) technology evoked the attention to surrogate radiopharmaceuticals and imaging modalities for bone. Actually, fluorine-18 ($^{18}$F) was the first bone seeking radiotracer before the introduction of $^{99m}$Tc-labeled agents even though its clinical application failed to become pervasive anymore after the rapid spread of Anger type gamma camera systems in early 1970s. However, rapidly developed PET technology made us refocus on the usefulness of $^{18}$F as a PET tracer. Early study comparing $^{18}$F-Na PET scan and planar bone scintigraphy reported that PET has higher sensitivity and specificity in the diagnosis of metastatic bone lesions than planar bone scan. Subsequent reports comparing between PET and both planar and SPECT bone image also revealed better results of PET scan in similar study groups. Rapid clinical application of PET/CT also accumulated considerable amount of experiences in skeletal evaluation and this modality is known to have better diagnostic power than stand alone PET system as well as bone scan. Furthermore $^{18}$F-Na PET/CT revealed better or at least equal results in detection of primary and metastatic bone lesions compared with CT and MRI. Therefore, it is obvious that $^{18}$F-Na PET/CT has potential to become new imaging modality for practical skeletal evaluation so continuous and careful evaluation of this modality and radiopharmaceutical must be required.

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Temporomandibular Disorder Caused by Nasopharyngeal Cancer (비인두암종에 의한 측두하악장애)

  • Byun, Young-Sub;Kim, Ki-Seo;Ahn, Hyung-Joon;Choi, Jong-Hoon;Kwon, Jeong-Seung
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.395-399
    • /
    • 2008
  • Orofacial pain and limited range of mouth opening as symptoms of temporomandibular disorder are mainly triggered by the structural and/or functional changes of temporomandibular joint and related structure itself. But careful diagnostic evaluation should be needed because they may be occurred by another pathologic conditions such as neoplasm in head and neck region. If there would be atypical pain characteristics or clinical features, systemic comorbid symptoms, or poor response to treatment, advanced imaging modalities such as CT or MRI will be mandatory for differential diagnosis. We experienced the case which was diagnosed as nasopharyngeal cancer mimicking temporomandibular disorder, and reviewed clinical considerations for proper differential diagnosis.

The Effect of Korean Medicinal Admission Treatment and Radiological Characteristics on 25 Cases of Spondylolysis (척추분리증 환자 25예의 한방 입원치료 효과와 영상의학적 특성)

  • Lee, Sang-Won;Kim, Yang-Sun;Kim, Yong-Wha;Kim, Yu-Gon;Park, Han-Sol;Lee, Ji-Eun;Lim, Jin-Woong;Jeong, Hyeon-Gyo;Choi, In-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.1
    • /
    • pp.95-103
    • /
    • 2020
  • Objectives The purpose of this study is to assess the effect of korean medicinal admission treatment for degenerative lumbar diseases with spondylolysis and analyze their radiological findings. Methods This study was performed on 25 cases' medical records of spondylolysis patients with both X-rays and MRI images. Their general characteristics, morphologies of intervertebral discs, grades of spondylolisthesis, grades of intervertebral foraminal stenosis were analyzed. The efficacy of treatment was evaluated by numeric pain rating scale (NPRS) changes and statistically assessed by paired t-test using program R Studio. Results After admission treatment, NPRS scores significantly decreased from 6.76±2.07 to 2.38±1.22 (p<0.01). Spondylolysis was associated with degenerative disc change and intervertebral foraminal stenosis at the same or adjacent vertebral level. In spondylolisthesis cases (76%), forward slippage occurred at the same level of spondylolysis in every case. Conclusions Spondylolysis could play a key role in the lumbar degenerative mechanism and korean medicinal admission treatment is effective on pain relief of degenerative lumbar diseases with spondylolysis.

Meniscal Repair with Meniscal Arrows (반월상연골 화살을 이용한 반월상연골 봉합술)

  • Kim Jung-Man;Oh In-Soo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.124-130
    • /
    • 2002
  • Purpose: The results of meniscal repair of peripheral tear of meniscus with meniscal arrow was analysed. Materials and Methods: Peripheral tears of posterior 1/2 of menisci of 25 cases including 18medial, 6 lateral and 1 both menisci were repaired with meniscal arrows. One to six meniscal arrows were used for each meniscus according to the length of tears. Concurrent tears of ACL were noted in14 cases. The follow-up period was 3.4 years in average. The findings of physical examination and MRI which were taken once or twice in 1$\~$5 years after operation were evaluated. Results: Healing of the tear was achieved in all cases. However, a vertical longitudinal tear of body occurred in two medial menisci along the line of insertion of arrows. An arrow migrated subcuta-neously in two cases, respectively. Conclusions: The meniscal arrow was effective in the treatment of the peripheral tear of menicus. However, there was a chance of occurrence of longitudinal tear of the meniscus in case of insertion of arrows in a row. Migration of the arrow may occur.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.