• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.025 seconds

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

Development of Next Medical Imaging System beyond MRI (POST MRI 시대를 위한 3차원 차세대 의료영상기술 개발)

  • Hong, H.B.;Shin, S.W.;Park, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.96-104
    • /
    • 2014
  • 1895년 독일 과학자 Wilhelm Roentgen 박사가 X-ray를 발견하고 미국의 Herman Carr가 MRI(Magnetic Resonance Imaging)의 기본 원리를 개발하여 발표한 이후 전자기장을 이용한 비침습적 의료영상 이미지 시스템은 놀라운 발전을 계속하여 왔다. 하지만, X-ray, CT(Computed Tomography), PET(Positron Emission Tomography)의 경우는 방사능의 사용과 조영제의 독성이라는 문제로 인하여 안전성에 대한 계속적인 문제를 야기해왔고 상대적으로 안전성이 입증된 MRI의 경우는 장비 자체 및 운용비가 일반화되기에는 고가여서 우리나라를 포함한 선진국에서도 아주 제한적으로 운영되고 있는 실정이다. 따라서, 세계적으로도 이러한 문제를 해결하기 위하여 안전하면서도 상대적으로 저렴한 비용으로 운용이 가능한 의료영상장비를 개발하기 위하여 많은 노력들이 경주되고 있어 관련 연구동향 및 산업화 동향을 소개하고자 한다.

  • PDF

Pathophysiology and MRI Findings of Infectious Spondylitis and the Differential Diagnosis (감염성 척추염과 감별질환의 병태생리와 MRI 소견)

  • Sunjin Ryu;Yeo Ju Kim;Seunghun Lee;Jeongah Ryu;Sunghoon Park;Jung Ui Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1413-1440
    • /
    • 2021
  • On MRI, abnormal signals of the intervertebral disc, destruction of the upper and lower vertebral body endplate around the disc, and bone marrow edema around the endplate are considered typical findings of infectious spondylitis. These findings can also appear in various non-infectious spinal diseases, such as degenerative changes, acute Schmorl's node, spondyloarthropathy, synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO), chronic recurrent multifocal osteomyelitis, and calcium pyrophosphate dihydrate crystal deposition disease. The imaging findings of infectious spondylitis that can be differentiated from these non-infectious spinal diseases on MRI are high signal intensity and abscess of the disc space, an abscess in the paraspinal soft tissue, and the loss of the linear low signal intensity on T1-weighted images of the bony endplate. However, these differentiation points do not always apply since there are many similarities in the imaging findings of infectious and non-infectious diseases. Therefore, for an accurate diagnosis, it is important to know the imaging characteristics related to the pathophysiology of not only infectious spondylitis but also non-infectious spinal diseases, which requires differentiation from infection.

Acalculous Hemorrhagic Cholecystitis with Chronic Intraluminal Hematoma: MRI Findings (혈종을 동반한 무결석 출혈성 담낭염: 자기공명영상소견)

  • Oh, Sang-Young;Park, Mi-Hyun;Jee, Keum-Nahn;Jeon, Gyeong-Sik;Kim, Hong-Ja
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.195-198
    • /
    • 2009
  • Acalculous hemorrhagic cholecystitis is a rare complication of acute cholecystitis and is associated with a high mortality rate. We present a case of acalculous hemorrhagic cholecystitis with hematoma in the gallbladder lumen, which was diagnosed using magnetic resonance imaging (MRI). The T1- & T2-weighted MRI revealed gallbladder distension with a hypointense intraluminal hematoma. The excellent tissue contrast provided by MRI is useful for detecting hematomas in the cases of hemorrhagic cholecystitis.

  • PDF

Remotely controlled Interactive Magnetic Resonance Imaging in Network Environment (Network을 이용한 원격 핵자기 공명 영상)

  • Park, J.I.;Kim, C.Y.;Park, D.J.;Ryu, W.S.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1383-1385
    • /
    • 1996
  • A network based interactive magnetic resonance imaging (MRI) system has been developed using the World Wide Web. For this purpose, an HTTP server is developed on the host computer of the MRI system. Capabilities of video and audio conferencing are included for monitoring experiment. Using the developed system. MRI imaging has been successfully carried out at the Signal Processing Lab in the Kwangwoon University with the remote MRI system located at the Medical Image Research Center at the KAIST in Daejon.

  • PDF

Synovial Sarcoma of the Anterior Chest Wall: A Case Report (앞가슴벽에 생긴 윤활막육종: 증례 보고)

  • Mingook Kim;Seung Eun Lee;Joon Hyuk Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1227-1233
    • /
    • 2020
  • Synovial sarcoma is a malignant soft tissue tumor that usually involves the extremities, particularly near the knees; a synovial sarcoma originating in the chest wall is extremely rare. We describe a 26-year-old woman diagnosed with a synovial sarcoma originating in the chest wall, based on CT and MRI findings. Contrast-enhanced CT images revealed a small, well-defined enhancing mass with calcification, in the subpleural area. This lesion was initially diagnosed as a benign tumor; however, the patient developed sudden severe pain with spontaneous bleeding and hemothorax, suggesting the possibility of malignancy. MRI revealed a multilobulated mass with a fluid-fluid level, which characterizes a synovial sarcoma.

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

Detection of Brain Ventricle by Using Wavelet Transform and Automatic Thresholding in MRI Brain Images (MRI 뇌 영상에서 웨이브릿 변환과 자동적인 임계치 설정을 이용한 뇌실 검출)

  • Won, Chul-Ho;Kim, Dong-Hun;Woo, Sang-Hyo;Lee, Jung-Hyun;Kim, Chang-Wook;Chung, Yoon-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.9
    • /
    • pp.1117-1124
    • /
    • 2007
  • In this paper, an algorithm that can define the threshold value automatically proposed in order to detect a brain ventricle in MRI brain images. After the wavelet transform, edge sharpness, which means the average magnitude of detail signals on the contour of the object, was computed by using the magnitude of horizontal and vertical detail signals. The contours of a brain ventricle were detected by increasing the threshold value repeatedly and computing edge sharpness. When the edge sharpness became maximal, the optimal threshold was determined, and the detection of a brain ventricle was accomplished finally. In this paper, we compared the proposed algorithm with the geodesic active contour model numerically and verified the efficiency of the proposed algorithm by applying real MRI brain images.

  • PDF

Extremely Rare CT and MRI Findings of Peritoneal Leiomyoma Mimicking Hepatic Mass: A Case Report (매우 드문 간종괴로 오인된 복막 평활근종의 CT 및 MRI 소견: 증례 보고)

  • Jonghun Woo;Seo-Youn Choi;Hee Kyung Kim;Ji Eun Lee;Min Hee Lee;Sanghyeok Lim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.946-951
    • /
    • 2023
  • Leiomyoma is a common benign tumor from smooth muscle cells, mostly in the uterus. Peritoneal leiomyomas (PLs) are extremely rare and mostly reported as disseminated peritoneal leiomyomatosis. However, to the best of out knowledge, radiologic findings of isolated PL are not reported in English literature. Herein, we introduce the radiologic findings of PL mimicking hepatic mass in a 34-year-old female. CT showed a mass with curvilinear heterogeneous enhancement at the liver's peripheral area. On MRI, the mass showed gradual and heterogeneous enhancement on gadoxetic acid-enhanced MRI and diffusion restriction. The radiologic diagnosis was a benign hepatic tumor, such as degenerated hemangioma, adenoma, and inflammatory myofibroblastic tumor; however, the mass was diagnosed as PL pathologically.

Effects of the Variability of Individual Data on the Group Results; an Acupuncture Study Using fMRI (기능적 자기공명영상을 이용한 침 연구에 있어서 개체 별 다양성이 그룹분석에 미치는 영향 연구)

  • Bae, Seong-In;Jahng, Geon-Ho;Ryu, Chang-Woo;Lim, Sabina
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.277-289
    • /
    • 2009
  • Recently, functional MRI has been used to investigate the neurobiological mechanisms of acupuncture and the specificity of acupoint. The group data tend to be regarded as more important than the individual data in the most of previous studies. This study was designed to investigate the effect of the variability of individual data on the group results. A functional MRI (fMRI) of the whole brain was performed in fifteen healthy subjects during placebo and acupuncture stimulations at the ST36 acupoint. After remaining at rest for 30 seconds, the acupuncture was inserted and twisted at the rate of 2 Hz for 45 seconds and then the acupuncture was removed immediately. This process was repeated three times. Individual and group analyses were performed by voxel-based analyses using SPM2 software. Visual inspections of the activation and deactivation maps from individual sessions have shown the large variability across fifteen subjects. This means that the group data reflected the brain activation responses of only a few subjects. We suggest that the individual data should be presented to demonstrate the effect of acupuncture.

  • PDF