• Title/Summary/Keyword: MRI 소음

Search Result 20, Processing Time 0.03 seconds

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Study on Analysis of Acoustic Noise in MRI (자기 공명 영상법에서의 소음 분석에 관한 연구)

  • Park, S.H.;Chung, S.T.;Chung, S.C.;Cho, Z.H.;Moon, C.W.;Yi, J.H.;Sin, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.550-554
    • /
    • 1997
  • Acoustic or sound noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as unctional MRI (fMRI). Our recent observations in MRI or the visual and motor cortex show very different results with sound noise in comparison with the results obtained without sound noise. Although a number of ideas has been suggested in the literature about the possible elimination or reduction of sound noise, progress has been slow due to the basic role of gradient pulsing in MR imaging. Therefore, we report on some typical behavior of sound noise observed from MRI scanners and the analyses of their characteristics. Data are obtained both from a commercial MRI scanner (GE Signa 1.5-T EPI system).

  • PDF

Comparison of Claustrophobia, Noise Sensitivity and Vital Signs according to Anxiety Sensitivity Level before and after MRI (자기공명영상(MRI) 검사 전·후 불안민감성 제수준에 따른 폐쇄공포, 소음민감성 및 활력징후 비교)

  • Park, Young-Hae
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.6
    • /
    • pp.950-959
    • /
    • 2008
  • Purpose: The present study was conducted in order to examine claustrophobia, noise sensitivity and vital signs according to anxiety sensitivity level in patients who have Magnet Resonance Imaging(MRI). Methods: With 100 outpatients, we measured anxiety sensitivity, claustrophobia, noise sensitivity and vital sign before and after MRI. Measuring tools were ASI, CLQ-M, and NSI. Data were collected from February to March, 2008. Results: The ASI score was higher in women than in men(p < .05), and no statistically significant difference was observed according to age, region of scanning, experience in MRI, and the use of contrast agent. Both men and women patients showed the same ASI score and decrease in CLQ M and NSI between before and after MRI. In women, ASI, CLQ M and NSI were in positive correlation with one another(p < .001), and in men, there was no correlation between ASI and CLQ M, and positive correlation was observed with NSI(p < .05). In comparison according to ASI level, blood pressure and pulse rate were not different in men and women. CLQ M was not different in men, but was different in women(p < .001). NSI was different in both men and women(men p < .05; women p < .001). Conclusion: MRI may cause claustrophobia in patients with high anxiety sensitivity, and noise appears to aggravate anxiety. In particular, claustrophobia was more serious in women than in men. Therefore, it is necessary to develop nursing interventions to reduce anxiety sensitivity particularly for female patients, and to make plans to educate and lower noise before MRI in order to reduce claustrophobia.

  • PDF

Acoustic Effects on fMRI : A Study on Auditory, Motor and Visual cortices (소음이 뇌기능 영상에 미치는 영향 : 청각, 운동, 시각 피질에 관한 연구)

  • Chung, S.C.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.71-74
    • /
    • 1997
  • MR acoustic sound or noise due to gradient pulsings has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources which obscures the small signals obtainable from the subtle changes occurring in oxygenation status in the cortex and blood capillaries. Therefore, we have studied the effects of acoustic or sound noise arising in fMR imaging of the auditory, motor and visual cortices. The results show that the acoustical noise effects on motor and visual responses are opposite. That is, for the motor activity, it shows an increased total motor activation while for the visual stimulation, corresponding (visual) cortical activity has diminished substantially when the subject is exposed to a loud acoustic sound. Although the current observations are preliminary and require more experimental confirmation, it appears that the observed acoustic-noise effects on brain unctions, such as in the motor and visual cortices, are new observations and could have significant consequences in data observation and interpretation in future fMRI studies.

  • PDF

Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence (1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.491-496
    • /
    • 2018
  • The purpose of this study is to analyze the noise spectra in DWI (diffusion-weighted imaging) pulse sequences of 1.5 Tesla and 3.0 Tesla MRI, The ACR (American College of Radiology) phantom and noise spectrum were analyzed by FFT (fast Fourier transform) and TFFT (temporal frequency analysis) using WavePad sound editor version 8.13 (NCH software, Greenwood Village, CO, USA). Noise spectra, FFT and TFFT were analyzed for laboratory 1.5Tesla and 3.0Tesla DWI MR pulse sequences. The noise threshold of the frequency amplitude in the FFT and TFFT at 3.0Tesla compared to 1.5Tesla was between 1.5Tesla and -6 dB, and between 3.0Tesla and 0 dB, the DWI pulse sequence for the patient's noise reduction was appropriately MR examination needs to be applied.

Studies on Possibility of Emotional State's Measurement using functional Magnetic Resonance Imaging (뇌기능영상을 이용한 감성지수 측정 가능성에 관한 연구)

  • 정순철;민병찬;김철중;김상균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.231-236
    • /
    • 1999
  • 외부의 자극에 따른 인간 감성 변화의 실체를 파악하고자 심리학, 생리학, 의공학 등의 분야에서 많은 연구가 이루어져 왔다. 본 논문은 fMRI의 기본 원리와 지금까지 저자들의 fMRI 연구 내용을 중심으로 감성 변화의 측정에 이용 또는 응용 가능성이 있는 실험 결과들에 대해서 서술하고자 한다. 먼저 자극강도에 따른 해당피질에서의 활성화 영역의 분석을 통해 외부 자극과 반응 영역간의 정량적인 측정이 가능하다는 것을 보였다. 둘째로 시간축 신호의 해석을 통해 감성 변화의 추이를 관찰할 수 있다는 것을 보였다. 마지막으로 간섭요인 (소음)이 뇌기능에 미치는 영향에 대한 분석을 통해 감성의 변화가 이의의 뇌기능 수행에 미치는 영향을 유추해 보았다.

  • PDF

A case of patient diagnosed as and treated with Hyeongbangdojeoksan (소음인(少陰人)으로 오진(誤診)한 소양인(少陽人) 결흉(結胸) 치험례(治驗例))

  • Park, Hye-San;Kim, Hyoung-Son;Joo, Jong-Cheon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.14 no.2
    • /
    • pp.147-152
    • /
    • 2002
  • One woman, Sixty three years old, suffered from chest pain, abdominal pain, nausea and vomiting for about three months. Although many examinations, brain magnetic resonance imaging(MRI), chest computed tomography(CT), abdominal CT, gastric endoscope, abdominal ultrasonography, and so forth, was performed from every point of view, those were non-significant. At first, I wrongly diagnosed her case as disease of Soumin and gave Soumin Gwakhyangjeongkisan. But she complained of diarrhea and chest discomfort. I re-diagnosed her case as Soyangin Gyeolhyung and treated with Hyeongbangdojeoksan, herbal medicine, consisted of Rhizoma Rehmanniae(生地黃), Lignum Akebiae(木通), Radix Scrophulariae(玄蔘), Semen Trichosanthis(瓜蔞仁), etc. Three weeks have passed from first visit and she did not suffered from pain. I experienced the excellent effect of Hyeongbangdojeoksan to Soyangin Gyeonlhyung.

  • PDF

Sasang Herb medicine, IRCT (InfraRed Computer Thermography), Yakchim (Korean herb-acupuncture) remedy (체통환자(體痛患者)의 사상의학적(四象醫學的) 사초(四焦)와 이목구비(耳目口鼻)를 중심(中心)으로 한 체열(體熱) 분석(分析))

  • Kim, Su-Beom;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.377-393
    • /
    • 1996
  • Lumbago is the common disease in the human, many people have been sicked the Lumbago. As the traditional methods of Lumbago treatment, acupuncture, moxibustion, herb medicines have been applied to a patient, nowadays, new methods have been applied physical remedy, Yakchim (Korean herb acupuncture) remedy, Chuna remedy to. This report was collected 73 Lumbago patients by name, sex, age, motive, symptoms, X-ray, CT, MRI, lRCT, Sasang constitution type, Sasang herb medicine, Yakchim, Chuna, period of remedy, satisfaction of remedy, at the "WooRee Korean Medical Clinic" during 21 months from Sep. 14, 1994 to May 25, 1996. And this report was studied about the distribution of the Sasang constitution type, the Sasang herb medicine, the effect, the period. The results were as follows: 1. Lumbago patients were distributed like that; Taeum-ln (太陰人) 47 (66.3 %), Soyang-In 16 (21.9 %), Soum-In (13.7 %), Taeyang-In (太陽人) 0. This was different from distribution of Donguisuseibowon (東醫壽世保元), Taeum-In (太陰人) 50%, Soyang-In (少陽人) 30 %, Soum-In (少陰人) 20 %, Taeyang-In (太陽人) little, this report shows that the number of Taeum-In (太陰人) is more than that of Donguisuseibowon and the number of Soum-In is less than that of Donguisuseibowon. 2. The average satisfaction of remedy was 60.3 %, Taeum-In's satisfaction was 66.0 %, Soum-In's satisfaction was 56.3 %, Soyang-In's satisfaction was 60.0 %. 3. The effective herb medicines were as follows, Soyang-In used the Hyong Bang Ji Hwang Tang (荊防地黃湯), Yuk Mi Ji Hwang Tang (六味地黃樓), Soum-In used the Sib Yi Mi Goan Jung Tang (十二味寬中湯), Taeum-In used the Chung Sim Yon Ja Tang (淸心蓮子陽), Chung Pae Sa Gan Tang (淸師爾肝湯), Yeol Da Han So Tang (熱多寒少湯). 4. The period of remedy was about 6 weeks. The period of remedy of each types was as follows, Taeum-In was about 5.7 weeks, Soum-In was about 6.8 weeks, Soyang-In was about 4.2 weeks. 5. The method of Lumbago remedy is divided three types, sprain Lumbago, Pyobyong (表病 : outside Syndromes) Libyong (裡病 : inside symdromes). Soum-In's methods are Pyobyong's ascending the Yang (陽), adding the Gi (氣) [升陽益氣], and Libyong's descending the inside Yim (裡陰) [裡陰降氣], Soyang-In's methods are Pyobyongs's decending the outside-Yim [表陰降氣], and Libyong's ascending the cool Yang (濟陽) [淸陽上升]. Taeum-In's methods are Pyobyong's ascending the Lung's Yang (肺陽升氣), and Libyong's colding the dried hot liver (淸肝燥熱). Taeyang's methods are strong the liver and making Yim. (補r肝生陰) 6. There are two methods for using the YakChim (Korean herb-acupuncture) by Sasang constitution medicine, one is to select the Yakchim, the other is to choice the point for appling the Yakchim. The first, to select the Yakchim, the other is follows; Soum-In can select the bee Venom, Soyang-In can select the H.O. (Hong Whoa 紅花), Taeum-In can select the I (Hodo 胡挑), V, O.K. (Ungdarn, 薦膽), Uwhang 牛黃, Sa-Hyang 麝香, etc., Palgang Yakchim (eight principles Korean herb-acupuncture (八剛藥鐵)) could made by abstracted Sasang herb medicine. The second, to choice the points for applying the Yakchim are used in the TaeGiuk Acupuncture method (太梗針法), Sacho (四焦, four warmer) by Sasang constritutional physiology and pathology.

  • PDF

Principle and Recent Advances of Neuroactivation Study (신경 활성화 연구의 원리와 최근 동향)

  • Kang, Eun-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.172-180
    • /
    • 2007
  • Among the nuclear medicine imaging methods available today, $H_2^{15}O-PET$ is most widely used by cognitive neuroscientists to examine regional brain function via the measurement of regional cerebral blood flow (rCBF). The short half-life of the radioactively labeled probe, $^{15}O$, often allows repeated measures from the same subjects in many different task conditions. $H_2^{15}O-$ PET, however, has technical limitations relative to other methods of functional neuroimaging, e.g., fMRI, including relatively poor time and spatial resolutions, and, frequently, insufficient statistical power for analysis of individual subjects. However, recent technical developments, such as the 3-D acquisition method provide relatively good image quality with a smaller radioactive dosage, which in turn results in more PET scans from each individual, thus providing sufficient statistical power for the analysis of individual subject's data. Furthermore, the noise free scanner environment $H_2^{15}O$ PET, along with discrete acquisition of data for each task condition, are important advantages of PET over other functional imaging methods regarding studying state-dependent changes in brain activity. This review presents both the limitations and advantages of $^{15}O-PET$, and outlines the design of efficient PET protocols, using examples of recent PET studies both in the normal healthy population, and in the clinical population.

Female External Genitalia and Urethra on MR Imaging: Optimal Pulse Sequence and Comparison of Anatomy in Premenopausal and Postmenopausal Women (여성 외부 생식기와 요도의 자기공명영상 소견: 적합한 영상기법과 폐경 전후의 해부학적 변화 비교)

  • Whang, Shin-Young;Ahn, Kyung-Sik;Sung, Deuk-Jae;Park, Beom-Jin;Kim, Min-Ju;Cho, Sung-Bum;Lee, Nam-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.146-153
    • /
    • 2011
  • Purpose : To describe normal anatomy and compare the differences of external genital organs and urethra on MR imaging in pre- and postmenopausal women. Materials and Methods : A total of 19 pre- and 18 postmenopausal healthy women underwent pelvis MR imaging at 1.5 T. Two radiologists retrospectively scored and compared the image quality of female external genitalia and urethra on axial T2-weighted images (T2WI) and axial fat-suppressed contrast-enhanced T1-weighted images (FSCE-T1WI) by using Wilcoxon signed ranks test. The radiologists compared the wall thickness or size of external genital organs and urethra on FSCE-T1WI between two groups by using Student t test. Results : Image quality was better with FSCE-T1WI than with T2WI in all subjects (p < 0.05). The vestibular bulb, clitoris and labium minor were more clearly visualized on FSCE-T1WI in premenopausal subjects rather than in postmenopausal subjects (p < 0.05). The urethra had a target-like appearance with three layers in premenopausal and postmenopausal subjects. Postmenopausal subjects were observed to have significantly smaller vaginal wall thickness, urethral wall thickness and vestibular bulb width than premenopausal subjects (p < 0.05). Conclusion : The anatomy and morphologic changes of female external genital organs and urethra were well discernible on FSCE-T1WI.