• Title/Summary/Keyword: MRA data

Search Result 84, Processing Time 0.036 seconds

eMRA: Extension of MRA Considering the Relationships Between MDR Concepts (eMRA: MDR의 개념간 관계성을 고려한 MRA 확장)

  • Joo, Young-Min;Kim, Jangwon;Jeong, Dongwon;Baik, Doo-Kwon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.3
    • /
    • pp.161-172
    • /
    • 2013
  • Metadata registry (MDR) is the international standard, developed by ISO/IEC for exchange and sharing data between databases. Many MDR systems are used in diverse domains such as medical service, bibliography, environment for sharing and integrating data. However, those systems have different physical structures individually because the MDR standard defines only the metamodel for registering and storing metadata. It causes heterogeneity between the system structures and requires additional cost to maintain interoperability. ISO/IEC 13249-8 Metadata Registry Access (MRA) is developing as an international standard to provide a consistent access facility to data stored in different metadata registries. However, MRA does not consider the relationships between the concepts (classes) defined in the MDR specification. It causes that incorrect query results returned from MDR systems. It also requires additional cost of modeling and rewriting queries to reflect each physical model. Therefore, this paper suggests eMRA which considers the relationships between the concepts in MDR. The comparative evaluations are described to show the advantages of eMRA. eMRA has superior performance in query modeling and referential integrity than MRA defined by the relationship between the concept of MDR.

Association Analysis for MRA Results of Defense R&D (국방연구개발사업 제조성숙도 평가결과에 대한 연관도 분석)

  • Eom, W
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.309-326
    • /
    • 2017
  • Purpose: The purpose of this study is to propose useful idea and data by association analyzing MRA results of defense research and development. Methods: The collected data through the DTaQ MRA system are analyzed using three association analysis measurements. Results: The results of this study are as follows; some evaluation items are very highly associated according to confidence and lift. The result is also meaningful as contents of evaluation items. The result of this study suggests a direction for improvement of MRA system. Conclusion: Some evaluation items of MRA are meaningfully associated. Therefore, the result can support the improvement of MRA system.

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

Development of Initial Ship Design Analysis System Based on MRA (MRA 기반 선박 초기설계 해석 시스템 개발)

  • Han J.S.;Kwon K.E.;Choi Y.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.3
    • /
    • pp.217-223
    • /
    • 2005
  • Tight integration between design and analysis processes and the data representation in the ship design application domain have been studied in this paper. Multi-Representation Architecture for design and analysis integration, proposed at Georgia Institute of Technology, has been carefully investigated for the application in the initial ship design stage. The MRA approach facilitates efficient generation of analysis models from the initial ship design data, thus reducing design lead time. Easy generation of analysis model is important because it allows quick analysis iteration under frequent design changes. The SMM, ABB and PBAM are defined for the analysis model of the typical ship structure. Only a part of the typical initial ship design data has been considered in the experimental implementation of the proposed approach. However, the prototype implementation shows that the application of MRA approach in the structural ship design domain is quite feasible. It is also contemplated that the same approach can be extended for other design and analysis views in the ship design domain.

Predictive Modeling for Microbial Risk Assessment (MRA) from the Literature Experimental Data

  • Bahk, Gyung-Jin
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.137-142
    • /
    • 2009
  • One of the most important aspects of conducting this microbial risk assessment (MRA) is determining the model in microbial behaviors in food systems. However, to fully these modeling, large expenditures or newly laboratory experiments will be spent to do it. To overcome these problems, it has to be considered to develop the new strategies that can be used data in the published literatures. This study is to show whether or not the data set from the published experimental data has more value for modeling for MRA. To illustrate this suggestion, as example of data set, 4 published Salmonella survival in Cheddar cheese reports were used. Finally, using the GInaFiT tool, survival was modeled by nonlinear polynomial regression model describing the effect of temperature on Weibull model parameters. This model used data in the literatures is useful in describing behavior of Salmonella during different time and temperature conditions of cheese ripening.

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

IT Export-Import Fuction Estimation and MRA Effect (정보통신기기 산업의 대미 수출입 함수 추정을 통한 MRA효과)

  • Lim, Kwang-Sun;Park, Yong-Jadse
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.131-134
    • /
    • 2007
  • From January 2000 to September 2006, we use the 81 months of the data to estimate the exportation and importation function of the Korea information communications main device industry towards to U.S., and through this process we extract the cost elasticity. And from cost elsticity, we estimate the exportation and importation enlarging effect between Korea and U.S assumption of the exportation and importation reduction rate was givien to MRA contract between Korea and U.S.

  • PDF

Statistical Probability Analysis of Storage Temperatures of Domestic Refrigerator as a Risk Factor of Foodborne Illness Outbreak (식중독 발생 위해인자로서 가정용 냉장고의 온도에 대한 확률분포 분석)

  • Bahk, Gyung-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.373-376
    • /
    • 2010
  • The objective of this study was to present the proper probability distribution model based on the data obtained from surveys on domestic refrigerator food storage temperatures in home. Domestic refrigerator temperatures were determined as risk factors in foodborne disease outbreaks for microbial risk assessment (MRA). The temperature was measured by directly visiting 139 homes using a data logger from May to September of 2009. The overall mean temperature for all the refrigerators in the survey was $3.53{\pm}2.96^{\circ}C$, with 23.6% of the refrigerators measuring above $5^{\circ}C$. Probability distributions were also created using @RISK program based on the measured temperature data. Statistical ranking was determined by the goodness of fit (GOF, i.e., the Kolmogorov-Smirnov (KS) or Anderson-Darling (AD) test) to determine the proper probability distribution model. This result showed that the LogLogistic (-10.407, 13.616, 8.6107) distribution was found to be the most appropriate for the MRA model. The results of this study might be directly used as input variables in exposure evaluation for conducting MRA.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.