• Title/Summary/Keyword: MR3

Search Result 1,596, Processing Time 0.03 seconds

Study on Performance Comparison of MR Damper for Fluid Properties and Orifice Shapes (MR 유체물성과 오리피스 형상에 대한 MR 댐퍼 성능비교 연구)

  • Kwon, Young-Chul;Park, Sam-Jin;Kim, Ki-Young;Baek, Dae-Sung;Lee, Seok-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1305-1310
    • /
    • 2014
  • MR(Magneto-Rheological) damper generates the magnetic shear force due to the cohesiveness of MR fluid influenced by a magnetic field. MR fluid consists of magnetic particles and a base liquid. In the present study, the damping forces of MR damper were investigated for density 1.3, 1.5 and $1.7g/cm^3$, and viscosity 1000 and 10000cp, and for the change of orifice shapes. It was found that the increase in the density and viscosity of MR fluid could change the damping force of MR damper due to the magnetic effects. Also, the damping forces on orifice shapes increased as the orifice gap and length decreased. These results showed that the properties of MR fluid and orifice shapes were important for the optimum design of MR damper.

Experimental study on Magnetic Flow Characteristics of MR Fluid (MR 유체의 자기유동 특성에 대한 실험연구)

  • Lee, Seok-Hyun;Kim, Ki-Young;Baek, Dae-Sung;Kwon, Young-Chul;Park, Sam-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3611-3616
    • /
    • 2013
  • Physical characteristics of a magneto-rheological(MR) fluid can be influenced by a magnetic field. In the present study, the behaviors of MR fluid are visualized and the shear stresses are measured under the magnetic field for density 1.3, 1.5 and 1.7 $g/cm^3$, and viscosity 100, 1000 and 10000cp. When the magnetic field is applied, particles of MR fluid are arranged along lines of magnetic field. It is observed that the flow pattern of MR fluid under the magnetic field is different from that of MR fluid without the magnetic field. Shear stress of MR fluids under the magnetic field changes significantly. Shear stress by the magnetic field increases the shape of a quadratic equation. When the density changes from $1300kg/m^3$ to $1700kg/m^3$ at 2.0A, the shear stress increases about 33%.

Experimental Study on Physical Characteristics along Chemical Compositions of MR Fluid (MR 유체의 화학적 조성에 따른 물리특성 실험연구)

  • Baek, Dae-Sung;Lee, Seok-Hyun;Kim, Ki-Young;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4747-4752
    • /
    • 2013
  • Physical characteristics of a magneto-rheological(MR) fluid can be influenced by a magnetic field. MR fluid is a suspension of micrometer-sized magnetic particles in a base liquid such as oil. Therefore, the key issue is dispersion stability because density of micrometer-sized magnetic particles are different from that of oil. In the present study, dispersion stability and physical characteristics along chemical compositions of MR fluid are investigated. 216 kinds of MR fluids are made by using magnetic powder(#2), surfactant(#2), base oil(#2), functional additive(#3), density(#3) and viscosity(#3). From experimental results, SEM photograph, magnetic flux density, supernatant and sediment of 216 kinds of MR fluids are obtained.

Study on Simulation and Optimization of C3MR Liquefaction Cycle (천연가스 액화공정의 C3MR 냉동사이클의 공정모사와 최적화에 관한 연구)

  • Park, Chang Won;Cha, Kyu Sang;Lee, Sang Gyu;Lee, Chel Gu;Choi, Keun Hyung
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.67-72
    • /
    • 2013
  • The LNG liquefaction plant which have a higher value-added business in the LNG value chain takes about 35% of total cost. Liquefaction process is core technology of liquefaction plant. Almost all of cost which was consumed from the liquefaction plant, using for operation energy of liquefaction process. The cost can be reduced by increasing efficiency of liquefaction cycle. C3MR(propane pre-cooled, mixed refrigerant cycle) which liquefies NG using propane and MR cycle has the high efficiency, so C3MR is mostly used liquefaction process in LNG industry. In this study, process simulation and analysis were performed for C3MR process. C3MR process variables were found through this simulation and analysis, and then the process optimization was performed. It is considered that the results of process analysis, process variables and process optimization study can be utilized to develope new liquefaction process.

Proposal and Analysis of Primality and Safe Primality test using Sieve of Euler (오일러체를 적용한 소수와 안전소수의 생성법 제안과 분석)

  • Jo, Hosung;Lee, Jiho;Park, Heejin
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.438-447
    • /
    • 2019
  • As the IoT-based hyper-connected society grows, public-key cryptosystem such as RSA is frequently used for encryption, authentication, and digital signature. Public-key cryptosystem use very large (safe) prime numbers to ensure security against malicious attacks. Even though the performance of the device has greatly improved, the generation of a large (safe)prime is time-consuming or memory-intensive. In this paper, we propose ET-MR and ET-MR-MR using Euler sieve so it runs faster while using less memory. We present a running time prediction model by probabilistic analysis and compare time and memory of our method with conventional methods. Experimental results show that the difference between the expected running time and the measured running time is less than 4%. In addition, the fastest running time of ET-MR is 36% faster than that of TD-MR, 8.5% faster than that of DT-MR and the fastest running time of ET-MR-MR is 65.3% faster than that of TD-MR-MR and similar to that of DT-MR-MR. When k=12,381, the memory usage of ET-MR is 2.7 times more than that of DT-MR but 98.5% less than that of TD-MR and when k=65,536, the memory usage of ET-MR-MR is 98.48% less than that of TD-MR-MR and 92.8% less than that of DT-MR-MR.

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

Network Mobility Handoff Scheme to Support Fast Route Optimization in Nested Network Mobility (중첩된 이동 네트워크 환경에서 빠른 경로 최적화를 지원하는 핸드오프 방안)

  • Lee, Il-Ho;Lee, Jun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.5
    • /
    • pp.119-131
    • /
    • 2009
  • Existing proposals on route optimization for nested Network Mobility(NEMO) have a problem that it is difficult to optimize a route promptly in an environment where a MR moves frequently. Also, they have L3 handoff latency as well as route optimization latency until an optimized route is formed. In this paper, we propose a L3 handoff scheme that supports fast route optimization for nested NEMO without any additional optimization procedure. To achieve this, our proposed scheme is designed to include a procedure that an AR acquires address informations of a MR. After receiving binding update message from the MR, the AR performs the binding update procedure with the MR's HA on behalf of the MR. Packets are delivered to the AR only passing by the MR's HA after a bi-directional tunnel is formed between the AR and the HA. The result of our performance evaluation has shown that the proposed scheme could provide excellent performance compared with the RRH and the ONEMO.

Automatic segmentation of 3-D brain MR images (3차원 두뇌 자기공명영상의 자동 Segmentation 기법)

  • Huh, S.;Lee, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.60-61
    • /
    • 1998
  • In this paper, we propose an algorithm for automatic segmentation of 3-dimesional brain MR images. In order to segment 3-dimensional brain MR images, we start segmentation from a mid-sagittal brain MR image. Then the segmented mid-sagittal brain MR image is used as a mask that is applied to the remaining lateral slices. Then we apply preprocessing, which includes thresholding and region-labeling, to the lateral slices, resulting in simplified 3-D brain MR images. Finally, we remove remaining problematic regions in the 3-dimensional brain MR image using the connectivity-based thresholding segmentation algorithm. Experiments show satisfactory results.

  • PDF

Vibration Control of MR Suspension System Considering Damping Force Hysteresis (댐핑력 히스테리시스를 고려한 MR 서스펜션의 진동제어)

  • Seong, Min-Sang;Sung, Kum-Gil;Han, Young-Min;Choi, Seung-Bok;Lee, Ho-Guen
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.315-322
    • /
    • 2008
  • This paper presents vibration control performances of a commercial magnetorheological(MR) suspension via new control strategy considering hysteresis of the field-dependent damping force of MR damper. A commercial MR damper which is applicable to high class passenger vehicle is adopted and its field-dependent damping force is experimentally evaluated. Preisach hysteresis model for the MR damper is identified using experimental first order descending(FOD) curves. Then, a feed-forward compensation strategy for the MR damper is formulated and integrated with a linear quadratic regulation(LQR) feedback controller for the suspension system. Control performances of the proposed control strategy for the MR suspension is experimentally evaluated with quarter vehicle test facility.

Segmentation and Visualization of Head MR Image Based on Structural Approach (구조적인 기법을 이용한 머리 MR 단층 영상의 조직 분류 및 가시화)

  • 권오봉;김민기
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • Because MR(Magnetic Resonance) slice images have much information of functions about body organs, it is very effeclive for diagnoses lo analyze and visualize MR slice images. A visuahzation process is composed of medical image acquisition, preprocessmg, segmentation, inlerpolation, rendering. Segmentation and interpolation among thenl ,1re currenl hot topics because of MR slice image imperfections. This paper proposes a method for segmentalion, mlerpolation respectively and addresses 3 D-visualizmg of a head. We segmented head tissues uomg otructural knowledge of head studied by clinical experiments sequentially. We improved the dynamic elastic inlerpolation to Utilize in concave conlour. We compared the proposed segmentation method and the interpolation method with other methods.

  • PDF