• 제목/요약/키워드: MR ratio

검색결과 447건 처리시간 0.03초

플라즈마 화학반응에 의한 연소가스 중 NOx. SOx 동시제거 특성 (Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Plasma Chemical Reaction)

  • 박재윤;고용술;이재동;손성도;박상현;고희석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.406-409
    • /
    • 1999
  • Experimental Investigations were carried out to remove NOx, SOx simultaneously from simulated flue gas[NO(0.02%)-SO$_2$(0.08%)-$CO_2$-Air-$N_2$] by using a plasma chemical reaction. Ammonia gas(14.81%) balanced by argon was diluted by all and was Introduced to mall simulated flue gas duct through NH$_3$ Injection system which is in downstream of reactor. The NH$_3$ molecular ratio(MR) was determined based on (NH3) to [NO+S0$_2$]. MR is 1, 1.5, 2.5. The NOx removal rate significantly increased with increasing NaOH bubble quantity. The SO$_2$ removal rate was not significantly effected by applied voltage, however it fairly Increased with increasing NH$_3$ molecule ratio. By-product aerosol particle was observed by XRD(X-ray diffraction) after sampling, The NOx, SOx removal rates, when H2O vapour bubbled by dry all was injected to plasma reactor, were better than those of other cases. When aqueous NaOH solution(20%) bubbled by 2.5( ι /min) of $N_2$ and 0.5 ( ι /min) NH$_3$(MR=1.5) were injected to simulated flue gas, The NOx. SOx removal rate was 95 ~ 100[%]

  • PDF

관류 강조 자기공명 영상을 이용한 소아 모야모야 환아의 뇌 혈역학 분석 (Cerebral Hemodynamic Analysis in Pediatric Moyamoya Patients using Perfusion Weighted MRI)

  • 장원석;김태곤;이승구;최중언;김동석
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.207-212
    • /
    • 2005
  • Objective: Classically, single photon emission tomography is known to be the reference standard for evaluating the hemodynamic status of patients with moyamoya disease. Recently, T2-weighted perfusion magnetic resonance(MR) imaging has been found to be effective in estimating cerebral hemodynamics in moyamoya disease. We aim to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic status of moyamoya disease. Methods: The subjects were fourteen moyamoya patients(mean age: 7.21 yrs) who were admitted at our hospital between Sep. 2001 to Sep 2003. Four normal children were used for control group. Perfusion MR imaging was performed before any treatment by using a T2-weighted contrast material-enhanced technique. Relative cerebral blood volume(rCBV) and time to peak enhancement(TTP) maps were calculated. Relative ratios of rCBV and TTP in the anterior cerebral artery(ACA), middle cerebral artery(MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery(PCA) in each cerebral hemispheres. Using this data, we analysed the hemodynamic aspect of pediatric moyamoya disease patients in regarding to the age, Suzuki stage, signal change in FLAIR MR imaging, and hemispheres inducing symptoms. Results: The mean rCBV ratio of ACA, MCA did not differ between normal children and moyamoya patients. However the significant TTP delay was observed at ACA, MCA territories (mean = 2.3071 sec, 1.2089 see, respectively, p < 0.0001). As the Suzuki stage of patients is advanced, rCBV ratio is decreased and TTP differences increased. Conclusion: Perfusion MR can be applied for evaluating preoperative cerebral hemodynamic status of moyamoya patients. Furthermore, perfusion MR imaging can be used for determine which hemisphere should be treated, first.

적산 일사 제어법으로 관수하는 순환식 수경재배에서 배액 혼합 방식에 의한 재사용 양액 내 양분 조정효과 비교 (Comparison of Nutrient Replenishing Effect under Different Mixing Methods in a Closed-loop Soilless Culture using Solar Radiation-based Irrigation)

  • 안태인;신종화;노은희;손정익
    • 생물환경조절학회지
    • /
    • 제20권4호
    • /
    • pp.247-252
    • /
    • 2011
  • 순환식 수경재배에서 배액의 EC, 부피, 관수량은 재사용 양액의 혼합비율을 결정하는 중요한 요소 중 하나이다. 적산 일사량 제어법으로 관수할 경우 일일 관수량의 예측은 곤란하며 일반적으로 고정된 혼합비율을 사용한다. 이 경우 새 양액이 고정적으로 투입되어 양분의 조정 효과가 기대되지만, 때때로 배액의 강제배출을 필요로 한다. 본 연구는 적산 일사량 제어법으로 관수하는 순환식 수경재배 조건에서 배액의 혼합비를 고정한 처리구(FR)와 정해진 혼합 용량 내에서 배액의 부피와 EC에 따라 혼합비를 변경하는 처리구(MR)의 재사용 양액 내 양분 조정효과를 비교하여 양수분 이용효율이 높은 혼합방식의 규명에 기여하고자 수행하였다. 배액의 농도 변화를 비교하기 위한 대조구로는 비순환식 수경재배 처리구(OP)를 구성하였다. FR처리구의 배액 혼합 비율은 배액의 희석 EC를 각각1.0, $2.0dS{\cdot}m^{-1}$로 설정하여 혼합처리를 적용하였다. MR 처리구의 경우는 혼합 용량을 1회 관수량을 기준으로 배액의 EC와 부피에 따라 혼합비율이 변경되도록 하였다. 배액의 누적 현상은 FR 1.0 처리구에서 관찰되었으며, FR 2.0과 MR 처리구에서는 배액 누적현상이 나타나지는 않았으나 MR 처리구의 배액 저장량이 FR 2.0 처리구에 비해서 낮게 나타났다. 배액과 재사용 양액 내 $Mg^{2+}:K^+:Ca^{2+}$$SO^{2-}_4:NO^-_3:PO^{3-}_4$의 당량 농도 간 비율 변화는 FR, MR 처리구에서 초기비율 대비 비교적 좁은 변화 범위를 나타냈다.

DC 모터와 MR 브레이크로 이루어진 하이브리드 구동기의 힘 제어 (Force Control of Hybrid Actuator Comprising DC Motor and MR Brake)

  • 최익;권동수;안진웅
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.46-55
    • /
    • 2006
  • 본 논문은 DC 모터와 MR(magnetorheological) 브레이크를 갖는 하이브리드 구동기의 제어 방법을 제안한다 로봇을 포함하여 여러 영역에서 이용되는 DC 모터는 대표적인 능동형구동기로 중량 대비 출력 이 작고, 출력한계로 인해 어느 정도 이상의 제어 이득에서 힘 제어 특성이 불안정해지는 성질이 있다. 따라서 이러한 DC 모터의 제어 불안정성을 해결하고, 투명성을 높이기 위해 반능동형 구동기인 MR 브레이크를 DC 모터와 병렬로 연결한 하이브리드 구동기를 제안하고 이에 대하여 네트워크 이론에 기반을 둔 제어 방법을 제안한다. 입력전류의 방향에 따라 스스로 출력을 내는 DC 모터와는 달리 MR 브레이크는 입력전류의 부호가 바뀌는 것에 상관없이 외부의 부하와 반대의 출력을 내는 것이 그 특징이다. 이러한 MR 브레이크의 성질을 수동적이라 하고 네트워크 이론의 수동성을 이용한 하이브리드 구동기의 힘 제어 방법을 제안하고 실험을 통해 이의 성능과 안정성을 입증하였다.

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권4호
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

급성 허혈성 뇌졸중에서 관류 자기공명영상과 99mTC-HMPAO 단광자방출단층촬영술을 이용한 뇌경색의 예측 (Prediction of Infarction in Acute Cerebral Ischemic Stroke by Using Perfusion MR Imaging and $^{99m}Tc-HMPAO$ SPECT)

  • Ho Cheol Choe;Sun Joo Lee;Jae Hyoung Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.55-63
    • /
    • 2002
  • 목적 급성 허혈성 뇌졸중에서 관류 MR영상으로 측정한 상대적 뇌혈용적과 단광자방출전산화단층촬영으로 측정한 상대적 뇌혈류량이 나중에 발생할 뇌경색을 예측할 수 있는지 알아보고자 하였다. 대상 및 방법 급성 일측성 중대뇌동맥 폐색 환자에서 증상 발생 6시간 이내에 관류 MR영상과 99mTc-HMPAO 단광자방출전산화단층촬영을 모두 시행한 13명을 대상으로 하였다. 동맥 폐색에 의한 허혈 부위와 반대측 정상 부위에서 각 관류 변수를 측정하여 그 비(허혈 부위 관류변수 값 / 정상 부위 관류 변수 값)를 구한 후, 나중에 경색으로 이행할 부위와 그렇지 않을 부위를 판별할 수 있는 관류변수 비의 절단값을 계산하였다. 결과 : 경색으로 이행한 부위와 그렇지 않은 부위에서 상대적 뇌혈용적 비의 평균값은 각각 $0.58{\pm}0.27{\;}and{\;}0.99{\pm}0.17$ (p<0.001)이었고, 상대적 뇌혈류량 비의 평균 값은 $0.41{\pm}0.22{\;}and{\;}0.71{\pm}0.14$ (p<0.001)이었다. 경색으로 이행할 부위와 그렇지 않을 부위를 판별하는 절단값은 상대적 뇌혈용적 비가 0.80, 상대적 뇌혈류량 비가 0.56이었다. 각 절단값의 민감도, 특이도, 능률은 뇌혈용적 비가 80.6, 87.5, 82.7%이었고 상대적 뇌혈류량 비가 72.2, 75.0, 73.0%이었다. (두 관류변수 사이에서 p>0.05). 결론 : 급성 허혈성 뇌졸중에서 상대적 뇌혈용적과 상대적 뇌혈류량의 측정은 뇌경색의 발생을 예측하는 데에 유용한 것으로 사료된다.

  • PDF

확산강조영상과 고식적 자기공명영상을 이용한 수술 전 축내 뇌종양의 경도 평가 (Pre-operative Evaluation of Consistency in Intra-axial Brain Tumor with Diffusion-weighted Images (DWI) and Conventional MR Images)

  • 오문식;안국진;최현석;정소령;이윤주;김범수
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권2호
    • /
    • pp.102-109
    • /
    • 2011
  • 목적 : 수술 전 축내 뇌종양의 경도를 평가하는데 확산강조영상 및 현성확산계수영상과 고식적 MR 영상의 유용성을 알아보고자 하였다. 대상 및 방법: 축내 뇌종양으로 수술을 받은 23명의 환자를 대상으로 T1, T2, 확산강조영상 소견을 후향적으로 분석하였다. 다양한 MR영상에서의 신호강도와 수술에서 평가한 종양의 경도를 정량적, 정성적으로 비교 분석하였다. 수술소견에서 종양의 경도는 낭성, 젤리같은, 쉽게 부서지는, 부드러운, 단단한, 딱딱한 정도로 나눴다. 세 명의 환자에서는 낭성 부분과 고형성 부분이 함께 있어서 각각에 대해서 평가하였다. 결과: 종양이 단단할수록 현성확산계수와 T2강조영상에서의 신호강도의 비는 더 낮았다 (p = 0.002, p = 0.01). 종양의 경도와 현성확산계수가 가장 강한 선형상관관계를 보였다 (r = -0.586, p = 0.002). 정성적 분석에서는 단단할수록 T2강조영상에서 정성적 신호강도 등급이 낮았다 (p = 0.018). 그 외 다른 MR소견은 통계분석에서 종 양의 경도와 유의한 상관관계를 보이지 않았다. 결론: 축내 뇌종양의 현성확산계수, T2강조영상에서 신호강도의 비와 정성적 신호강도 등급은 종양의 경도와 상관관계가 있었고 이는 수술 전 전략 수립에 많은 도움이 될 것으로 생각된다.

구조물의 진동 제어를 위한 압착식 MR 감쇠기의 동적 모델링 (Dynamic Modeling of Semi-active Squeeze Mode MR Damper for Structural Vibration Control)

  • 허광희;전준용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.172-180
    • /
    • 2009
  • 일반적으로 MR 감쇠기를 이용한 준능동 제어 시스템을 구축하기 위해서는 감쇠장치의 동적모델이 요구된다. 여기서, 동적모델링은 감쇠장치의 발생 감쇠력 및 거동 성향 등을 수치적으로 예측하는 것이다. 따라서 본 연구에서는 이러한 MR 감쇠기의 동적거동을 실무적인 관점에서 합리적으로 모델링하기 위하여 다양한 동적모델 중 Power 모델 및 Bingham 모델을 적용해 MR 감쇠기의 동적거동특성을 예측 평가하였다. 이때 활용한 MR 감쇠기의 실험결과는 압착식 형태로 개발된 MR 감쇠기를 대상으로 동하중 실험을 수행하여 획득하였으며, 힘-변위 이력곡선으로부터 준능동 제어장치로의 타당성을 확인하였다. 또한, 각 동적모델의 예측성능을 평가하기 위하여 우선 실험결과를 이용해 각 동적모델 별 모델변수를 규명하였고, 이를 바탕으로 힘-속도 관계곡선 및 예측된 발생 감쇠력의 오차율을 산출하여 개발된 압착식 MR 감쇠기의 실험결과와 상호 비교 평가하였다. 최종적으로 본 연구에서 개발한 압착식 MR 감쇠기는 준능동 제어장치로 활용 가능함을 확인하였고, 평가된 두 가지 동적모델은 모두 우수한 예측성능을 보임으로써 본 연구에서 개발한 압착식 MR 감쇠기는 물론 MR유체를 이용한 다양한 형태의 감쇠장치의 거동특성을 수치적으로 예측하기 위하여 간단히 활용될 수 있는 가능성을 제시하였다.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

Effects of Rapid Thermal Annealing on Thermal Stability of FeMn Spin Valve Sensors

  • Park, Seung-Young;Choi, Yeon-Bong;Jo, Soon-Chul
    • Journal of Magnetics
    • /
    • 제10권2호
    • /
    • pp.52-57
    • /
    • 2005
  • In this research, magnetoresistance (MR) ratio (MR), resistivity, and exchange coupling field $(H_{ex})$ behaviors for sputter deposited spin valves with FeMn antiferromagnetic layer have been extensively investigated by rapid thermal annealing (RTA) as well as conventional annealing (CA) method. 10 s of RTA revealed that interdiffusion was not significant up to $325^{\circ}C$ at the interfaces between the layers when the RTA time was short. The MR of FeMn spin valves were reduced when the spin valves were exposed to temperature of $250^{\circ}C$, even for a short time period of 10 s prior to CA. $H_{ex}$ was maintained up to $325^{\circ}C$ of CA when the specimen was subjected to 10 s of RTA at $200^{\circ}C$ prior to CA, which is $25^{\circ}C$ higher than the result obtained from the CA without prior RTA. Therefore, the stability of $H_{ex}$ could be enhanced by a prior RTA before performing CA up to annealing temperature of $325^{\circ}C$. MR and sensitivity of the specimens annealed without magnetic field up to $275^{\circ}C$ were recovered to the values prior to CA, but $H_{ex}$ was not recovered. This means that reduced MR sensitivity and MR during the device fabrication can be recovered by a field RTA.