• 제목/요약/키워드: MR flow effect

검색결과 30건 처리시간 0.035초

혼합현실 기술 사용자 체험이 플로우와 지속사용의도에 미치는 효과 (The Effect of User Experience on Perceived Flow and Continuous Intentions to Use the Mixed Reality Technology)

  • 김은영;성희원
    • 한국의류학회지
    • /
    • 제45권5호
    • /
    • pp.907-921
    • /
    • 2021
  • This study aims to predict causal relationships between experience economy, perceived flow, and continuous use intention in the mixed reality (MR) environment. A virtual fitting mirror with two modes (i.e., avatar and self-image) was selected for this study. A total of 200 samples was obtained in two sample frames: virtual fitting users in avatar mode (group 1, n = 119) and self-image mode (group 2, n = 81). The results showed that the experience economy consists of entertainment, education, esthetic, and escapism. The entertainment and esthetic experiences had positive effects on perceived flow, leading to continuous use intentions. For avatar mode, the entertainment and esthetic experiences had positive effects on continuous use intentions through the mediating effect of flow; and the education experience had a positive effect on the continuous intentions to use the MR technology. For self-image mode, the flow mediated the effect of entertainment on continuous use intentions, whereas education and escapism directly affected the intention to use the MR technology. The paper also discusses the theoretical and managerial implications of using MR technologies in fashion retailing.

유동해석을 통한 MR fluid jet polishing 시스템의 재료제거 특성 분석 (A study on material removal characteristics of MR fluid jet polishing system through flow analysis)

  • 신봉철;임동욱;이정원
    • Design & Manufacturing
    • /
    • 제13권3호
    • /
    • pp.12-18
    • /
    • 2019
  • Fluid jet polishing is a method of jetting a fluid to polish a concave or free-form surface. However, the fluid jet method is difficult to form a stable polishing spot because of the lack of concentration. In order to solve this problem, MR fluid jet polishing system using an abrasive mixed with an MR fluid whose viscosity changes according to the intensity of a magnetic field is under study. MR fluid jet polishing is not easy to formulate for precise optimal conditions and material removal due to numerous fluid compositions and process conditions. Therefore, in this paper, quantitative data on the factors that have significant influence on the machining conditions are presented using various simulations and the correlation studies are conducted. In order to verify applicability of the fabricated MR fluid jet polishing system by nozzle diameter, the flow pattern and velocity distribution of MR fluid and polishing slurry of MR fluid jet polishing were analyzed by flow analysis and shear stress due to magnetic field changes was analyzed. The MR fluid of the MR fluid jet polishing and the flow pattern and velocity distribution of the polishing slurry were analyzed according to the nozzle diameter and the effects of nozzle diameter on the polishing effect were discussed. The analysis showed that the maximum shear stress was 0.45 mm at the diameter of 0.5 mm, 0.73 mm at 1.0 mm, and 1.24 mm at 1.5 mm. The cross-sectional shape is symmetrical and smooth W-shape is generated, which is consistent with typical fluid spray polishing result. Therefore, it was confirmed that the high-quality surface polishing process can be stably performed using the developed system.

MR PC 영상을 이용한 유체 흐름 분석 (Measurement of Flow Velocity and Flow Visualization with MR PC Image)

  • 김수정;이동혁;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

유튜브 구독자의 이용과 충족에 관한 연구 : 의례적 이용동기, 도구적 이용동기, 몰입 및 만족을 중심으로 (Uses and Gratifications on Subscribed YouTube Channels : Centered on Motives for Ritualized use and Instrumental Use, Flow, and Satisfaction)

  • 주지혁
    • 한국융합학회논문지
    • /
    • 제10권12호
    • /
    • pp.223-233
    • /
    • 2019
  • 이 연구는 유튜브 구독자의 이용과 충족을 탐색하기 위해 PLS 경로분석을 통해 분석하였다. 특히 이 연구는 유튜브 구독자의 의례적 이용동기(Motives for Ritualized use)와 도구적 이용동기(Motives for Instrumental use) 구조를 확인하고, 이 두가지 동기가 만족에 직접적으로, 몰입(flow)을 매개로 간접적으로 영향을 미친다는 것을 밝혔다. PLS 경로 모형분석을 통해 변인들 사이의 구조적 인과관계를 분석하여, 제안된 가설이 모두 채택 되었다는 것을 밝혔다. 즉 유튜브 구독자의 만족은 의례적 이용동기와 도구적 이용동기에 의해서 직접적으로 그리고 몰입을 중개변인으로 하여 간접적으로 영향을 미치고 있음을 규명하였다. 끝으로 연구 결과의 함의와 후속 연구를 위한 제안을 제시하였다.

관류자기공명영상의 이해 (Understanding of Perfusion MR Imaging)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

뇌의 기능영상에 있어서 자화율효과와 혈류효과 연구 (Susceptibility Effects v.s Flow Effects in Functional MRI)

  • 박종배;정순철;박세혁;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.23-26
    • /
    • 1993
  • In MR functional imaging, it is shown that the signal change during photic activation is composed of two terms, i.e. the inflow effect and the susceptibility effect. Relatively the inflow effect affects the data obtained by CGE on the condition of short $T_E$(15ms) and large $\alpha$(90degree). The susceptibility effect, however, mainly contributes to the data on the condition of large $T_E$(35ms) and small $\alpha$(30degree). In this apper, we will discriminate the susceptibility effect for the intermingled data affected both flow effect and susceptibility effect. Finally susceptibility only functional imaging is proposed by using TRFGE.

  • PDF

Time of Flight 원리를 이용한 삼차원 자기공명 혈관조영술의 구현 (Magnetic Resonance Angiography using 3D Time-Of-Flight Method)

  • 이윤;류택현;김시승;안성혁;이만우;정관진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.96-97
    • /
    • 1998
  • 3D TOF MR Angiography is able to obtain thinner slice thickness, higher SNR, therefore higher spatial resolution than 2D TOF MR Angiography. Since it uses longer TR than 2D TOF MRA to allow stronger in-flow effect, the background tissue may not be fully saturated. Thus background tissue signal can be further suppressed by MTS(Magnetization Transfer Saturation). Flow-compensation was accomplished by GMN(Gradient Moment Nulling), and tracking saturation was used to suppress vein signal. The different flow signal at the entry of the slab and output of the slab can be compensated by TONE(Tilted Optimized Non-saturating Excitation) RF pulse.

  • PDF

Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여 (Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect)

  • 문치웅;김상태;노용만;임태환;조장희
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.243-251
    • /
    • 1997
  • 본 연구에서는 유체보상 경사자장 기법(flow-compensation-gradient of gradient-moment nulling method)을 이용하지 않은 Tailored RF를 이용한 TRFGE(tailored rf gradient echo) 영상에는 유체유입효과(in-flow effect)가 나타나지 않지만 절편(slice)내에서 판독경사자장(reading gradient)과 같은 방향으로 흐르는 유체는 신호가 강조가 됨을 이론과 실험으로 보였다. 절편 내에서 판독경사자장과 같은 방향으로 흐르는 유체의 신호가 TRFGE 영상에서 강조되는 이유를 이론적으로 설명하였으며 이 이론을 뒷받침 할 실험을 위해 유체 모형을 제작하였다. 원통 모양의 물 모형 중앙으로 유체 관을 통해 식염수(saline)가 주자장(B$B_0$)와 평행인 z 축 방향으로 흐를 수 있도록 하였다. 유체가 흐를 때와 흐르지 않을 때 CGE(conventional gradient echo) 영상과 TRFGE 영사을 얻어 각각 비교하였다. 유체 유입효과를 관찰하기 위해서는 횡단면(axial)의 영상을 얻었고 절편 내에서 판독경사자장과 같은 방향으로 흐르는 유체의 영상신호를 관찰하기 위해서 시상면(sagittal) 영상을 얻었다.

  • PDF

천막상부 뇌졸중에서 소뇌의 혈역학 변화 -Dynamic Susceptibility Contrast MR 영상을 이용한- (Effect of Supratentorial Stroke on Cerebellar Hemodynamic Parameters - Assessment by Dynamic Susceptibility Contrast MR Imaging)

  • 한시령;김범수;곽태호;최영빈;김영인
    • Annals of Clinical Neurophysiology
    • /
    • 제4권1호
    • /
    • pp.38-43
    • /
    • 2002
  • Background & Purpose : Dynamic susceptibility contrast MR imaging, one method of perfusion MRI, was developed to define cerebral hemodynamic status with good anatomical resolution. The authors investigated hemodynamic parameters using this imaging method, in an effort to identify hemodynamic changes on the remote crossed cerebellum of patients with a supratentorial infarct. Methods : Dynamic susceptibility contrast MR imaging was performed in 15 patients with only unilateral supratentorial infarcts. Imaging was obtained at the anatomic level of the cerebellum. rCBF, rCBV, MTT and TP were determined over both cerebellar hemispheres of interest. Results : The rCBF and rCBV values of the contralateral cerebellar hemisphere were significantly more decreased than those of the ipsilateral cerebellar hemisphere in 12 patients(p=0.028, 0.033). MTT and TP values of the contralateral and ipsilateral cerebellar hemispheres didn't reveal any differences(p=0.130, 0.121). Conclusions : The results of this work suggest that the region which are remote from the ischemic brain lesion shows no changes of MTT or TP but show decrease of rCBF and rCBV, mean to diaschisis, it also demonstrates that perfusion MRI is an easily available method to evaluate the hemodynamic status of the brain.

  • PDF

VR애니메이션 <Goodbye Mr Octopus> 연출 연구 (A Study of Direction of VR Animation <Goodbye Mr Octopus>)

  • 이태구;박수경
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.135-140
    • /
    • 2023
  • VR애니메이션은 애니메이션 속 공간에 위치하면서 기존 애니메이션 연출에서 볼 수 없는 360도 화면 연출을 볼 수 있다. 2020년에 제작된 VR 애니메이션 <Goodbye Mr Octopus>는 몰입형 단편 영화로 제77회 베니스 영화제에서 선정되었다. 열여섯 번째 생일을 맞은 사춘기 소녀 스텔라와 엄격한 아버지와의 갈등을 어머니의 편지로 해결되는 이야기이다. 총 11개의 씬으로 구성된 서사로 각 씬에는 시선유도, 시간흐름, 공간전환, 외화면 연출 등 VR영상 문법의 새로운 연출적 요소가 분석되었다. 시선유도 연출은 360도 시선의 불편함을 최소화하였으며, 시간 및 공간전환 연출은 서사적 사건에 따른 관객의 몰입도를 높이고, 외화면 연출은 VR공간의 확장 효과로 분석되었다.