• Title/Summary/Keyword: MR Imaging

Search Result 1,157, Processing Time 0.032 seconds

Localized MR Imaging Technique by Using Locally-Linear Gradient Field (부분적 경사자계를 이용한 국부자기공명 영상촬영기법)

  • Yang, Y.J.;Lee, J.K.;Jeong, S.T.;Cho, Z.H.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.247-249
    • /
    • 1995
  • A new localized imaging technique of reduced imaging time using a locally-linear gradient is proposed. Since most fast MR imaging methods need the whole k-space data corresponding to the whole imaging area, there are limitations in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging area. Conventional imaging sequences can be used without any RF/gradient pulse sequence modifications. The proposed localized imaging technique has been implemented on a 2.0 Tesla whole-body system at KAIST and the imaging results show the utility of the proposed technique.

  • PDF

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Detection of Malignant Primary Hepatic Neoplasms with Gadobenate Dimeglumine (Gd-BOPTA) Enhanced T1-Weighted Hepatocyte Phase MR Imaging: Results of Off-site Blinded Review in a Phase-II Multicenter Trial

  • Constantino S. Pena;Sanjay Saini;Richard L. Baron;Bernd A. Hamm;Giovanni Morana;Roberto Caudana;Andrea Giovagnoni;Andrea Villa;Alessandro Carriero;Didier Mathieu;Michael W. Bourne;Miles A. Kirchin;Gianpaolo Pirovano;Alberto Spinazzi
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.210-215
    • /
    • 2001
  • Objective: To investigate the efficacy of gadobenate dimeglumine (GdBOPTA) enhanced MR imaging for the detection of liver lesions in patients with primary malignant hepatic neoplasms. Materials and Methods: Thirty-one patients with histologically proven primary malignancy of the liver were evaluated before and after administration of GdBOPTA at dose 0.05 or 0.10 mmol/kg. T1-weighted spin echo (T1W-SE) and gradient echo (T1W-GRE) images were evaluated for lesion number, location, size and confidence by three off-site independent reviewers and the findings were compared to reference standard imaging (intraoperative ultrasound, computed tomography during arterial portography or lipiodol computed tomography). Results were analyzed for significance using a two-sided McNemar's test. Results: More lesions were identified on Gd-BOPTA enhanced images than on unenhanced images and there was no significant difference in lesion detection between either concentration. The largest benefit was in detection of lesions under 1 cm in size (7 to 21, 9 to 15, 16 to 18 for reviewers A, B, C respectively). In 68% of the patients with more than one lesion, Gd-BOPTA increased the number of lesions detected. Conclusion: Liver MR imaging after Gd-BOPTA increases the detection of liver lesions in patients with primary malignant hepatic neoplasm.

  • PDF

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Pulse Sequence based MR Images for Compressed Sensing Algorithm Applications (펄스열을 이용한 MR 영상의 Compressed Sensing 알고리즘 적용)

  • Gho, Sung-Mi;Choi, Na-Rae;Kim, Dong-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.5
    • /
    • pp.1-7
    • /
    • 2009
  • In recent years, compressed sensing (CS) algorithm has been studied in various research areas including medical imaging. To use the CS algorithm, the signal that is to be reconstructed needs to have the property of sparsity But, most medical images generally don't have this property. One method to overcome this problem is by using sparsifying transform. However, MR imaging, compared to other medical imaging modality, has the unique property that by using appropriate image acquisition pulse sequences, the image contrast can be modified. In this paper, we propose the possibility of applying the CS algorithm with non-sparsifying transform to the pulse sequence modified MR images and improve the reconstruction performance of the CS algorithm by using an appropriate sparsifying transform. We verified the proposed contents by computer simulation using Shepp-Logan phantom and in vivo data.

Fast MR Imaging Technique by Using Locally-Linear Gradient Field (부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법)

  • 양윤정;이종권
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

Improvement of SNR in DANTE Fast MR Imaging (MR DANTE 고속 영상에서 SNR의 개선에 관한 연구)

  • 정성택
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

The Emerging Role of Fast MR Techniques in Traumatic Brain Injury

  • Yoo, Roh-Eul;Choi, Seung Hong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.2
    • /
    • pp.76-80
    • /
    • 2021
  • Post-concussion syndrome (PCS) following mild traumatic brain injury (mTBI) is a major factor that contributes to the increased socioeconomic burden caused by TBI. Myelin loss has been implicated in the development of PCS following mTBI. Diffusion tensor imaging (DTI), a traditional imaging modality for the evaluation of axonal and myelin integrity in mTBI, has intrinsic limitations, including its lack of specificity and its time-consuming and labor-intensive post-processing analysis. More recently, various fast MR techniques based on multicomponent relaxometry (MCR), including QRAPMASTER, mcDESPOT, and MDME sequences, have been developed. These MCR-based sequences can provide myelin water fraction/myelin volume fraction, a quantitative parameter more specific to myelin, which might serve as a surrogate marker of myelin volume, in a clinically feasible time. In this review, we summarize the clinical application of the MCR-based fast MR techniques in mTBI patients.