• Title/Summary/Keyword: MR, experimental

Search Result 292, Processing Time 0.03 seconds

Semi-active Control of a Seismically Excited Cable-Stared Bridge Considering Dynamic Models of MR Fluid Damper (MR 유체 댐퍼의 동적모델을 고려한 사장교의 반(半)능동제어)

  • Jung, Hyung-Jo;Park, Kyu-Sik;Spencer, B.F.,Jr;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.63-71
    • /
    • 2002
  • This paper examines the ASCE first generation benchmark problem for a seismically excited cable-stayed bridge, and proposes a new semi-active control strategy focusing on inclusion of effects of control-structure interaction. This benchmark problem focuses on a cable-stayed bridge in Cope Girardeau, Missouri, USA, for which construction is expected to be completed in 2003. Seismic considerations were strongly considered in the design of this bridge due to the location of the bridge in the New Madrid seismic zone and its critical role as a principal crossing of the Mississippi River. In this paper, magnetorheological(MR) fluid dampers are proposed as the supplemental damping devices, and a clipped-optimal control algorithm is employed. Several types of dynamic models for MR fluid dampers, such as a Bingham model, a Bouc-Wen model, and a modified Bouc-Wen model, are considered, which are obtained from data based on experimental results for full-scale dampers. Because the MR fluid damper is a controllable energy-dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. Numerical simulation results show that the performance of the proposed semi-active control strategy using MR fluid dampers is quite effective.

A New Type Speaker Utilizing a Magneto-rheological Fluid Diaphragm (자기유변유체 다이어프램을 이용한 새로운 타입의 스피커)

  • Park, Jhin Ha;Yoon, Ji Young;Kim, Seon Hye;Lee, Tae Hoon;Lee, Soo Hyuk;Choi, Seung Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.182-188
    • /
    • 2017
  • In this work, a new type speaker which features various resonant frequencies is proposed utilizing a magneto-rheological (MR) fluid and its performance is evaluated in terms of the change of the field-dependent sound pressure level. In order to achieve this goal, a whole concept of the speaker system is firstly discussed and subsequently a controllable diaphragm is made using MR fluid whose rheological properties such as viscosity are controllable by the magnitude of magnetic field. Then, the proposed speaker system consisting of the inner structure and the squeeze mode type of MR diaphragm is established in an anechoic room The effectiveness of the proposed speaker system is experimentally evaluated at two different conditions; with and without the magnetic field. It is shown from experimental tests that the sound pressure level at different sound source can be controlled which is not able to achieve using one conventional speaker system.

Magnetic resonance imaging and spectroscopic analysis in 5 cases of Pelizaeus-Merzbacher disease: metabolic abnormalities as diagnostic tools

  • Lee, Eun;Yum, Mi-Sun;Choi, Hae-Won;Yoo, Han-Wook;You, Su Jeong;Lee, Eun-Hye;Ko, Tae-Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.10
    • /
    • pp.397-402
    • /
    • 2012
  • Pelizaeus-Merzbacher disease (PMD) is a rare, X-linked recessive disorder characterized by dysmyelination in the central nervous system. PMD results from deletion, mutation, or duplication of the proteolipid protein gene (PLP1) located at Xq22, leading to the failure of axon myelination by oligodendrocytes in the central nervous system. PMD may be suspected when there are clinical manifestations such as nystagmus, developmental delays, and spasticity, and genetic analysis can confirm the diagnosis. Further diagnostic manifestations of the disease include a lack of myelination on brain magnetic resonance (MR) imaging and aberrant N-acetyl aspartate (NAA) and choline concentrations that reflect axonal and myelination abnormalities on phroton MR spectroscopy. We report 5 cases of PMD (in 1 girl and 4 boys). PLP1 duplication was detected in 2 patients. Brain MR analyses and MR spectroscopy were performed for all the patients. The brain MR images showed white matter abnormalities typical of PMD, and the MR spectroscopic images showed diverse patterns of NAA, creatinine, and choline concentrations. We propose that MR spectroscopic analysis of metabolic alterations can aid the PMD diagnosis and can contribute to a better understanding of the pathogenesis of the disease.

Real-time Vibration Control of Cable Bridges using a Shear-type MR Damper-Focusing on Power Model and Lyapunov Control (전단형 MR 댐퍼를 이용한 케이블 교량의 실시간 진동제어-파워 모델 및 리야프노브 제어 중심으로)

  • Heo, Gwanghee;Lee, Chinok;Jeon, Seunggon;Kim, Chunggil;Jeon, Joonryong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.215-226
    • /
    • 2017
  • In this paper, an experimental study was carried out for vibration control of cable bridges with structurally flexible characteristics. For the experiment on vibration control, a model bridge was constructed by reducing the Seohae Grand Bridge and the shear type MR damper was designed using the wind load response measured at Seohae Grand Bridge. The shear type MR damper was installed in the vertical direction at the middle span of the model bridge, and dynamic modeling was performed using the power model. The tests of the vibration control were carried out by non-control, passive on/off control and Lyapunov control method on model bridge with scaled wind load response. The performance of the vibration control was evaluated by calculating absolute maximum displacement, RMS displacement, absolute maximum acceleration, RMS acceleration, and size of applied power using the response (displacement, acceleration, etc.) from the model bridge. As a result, the power model was effective in simulating the nonlinear behavior of the MR damper, and the Lyapunov control method using the MR damper was able to control the vibration of the structure and reduce the size of the power supply.

MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages

  • Jong Deok Lee;Jeong Min Lee;Sang Won Kim;Chong Soo Kim;Woo Sung Mun
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.151-158
    • /
    • 2001
  • Objective: To determine the ability of MR imaging to detect the pathological changes occurring in radiofrequency (RF) thermal lesions and to assess its accuracy in revealing the extent of tissue necrosis. Materials and Methods: Using an RF electrode, thermal lesions were created in the livers of 18 rabbits. The procedure involved three phases. In the acute phase, six animals were killed the day after performing thermal ablation with RF energy, and two on day 3. In the subacute and chronic phases, eight rabbits underwent percutaneous hepatic RF ablation. After performing MR imaging, two animals were sacrificed at 1, 2, 4, and 7 weeks after the procedure, and MRpathologic correlation was performed. Results: In the acute phase, the thermal ablation lesions appeared at gross examination as well-circumscribed, necrotic areas, representing early change in the coagulative necrosis seen at microscopic examination. They were hypointense on T2-weighted images, and hyperintense on T1-weighted images. Gadolinium-enhanced MR imaging showed that a thin hyperemic rim surrounded the central coagulative necrosis. In the subacute phase, ablated lesions also showed extensive coagulative necrosis and marked inflammation at microscopic examination. Beyond two weeks, the lesions showed gradual resorption of the necrotic area, with a peripheral fibrovascular rim. The size of lesions measured by MR imaging correlated well with the findings at gross pathologic examination. Conclusion: MR imaging effectively demonstrates the histopathological tissue change occurring after thermal ablation, and accurately determines the extent of the target area.

  • PDF

A Study on Tribological Properties of Magneto-Rheological Fluid (MRF) in Polishing Process (연마공정에서 MR 유체의 트라이볼로지적 성질에 대한 연구)

  • Lee S.O.;Jang K.I.;Min B.K.;Lee S.J.;Seok J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.497-498
    • /
    • 2006
  • Tribological properties of a Magneto-Rheological(MR) fluid in a polishing process are studied. For this polishing process, abrasive wear model is proposed as a function of shear force, normal force and actual mean velocity of MR particles at workpiece surface. Experimental conditions are changed by varying the gap distance between workpiece and tool and the rotational speed of tool. From the experimental results, a modified Stribeck curve is obtained, and the friction coefficient turns out to have linear relationship with a modified Sommerfeld number. The validity of the wear model is supported by additional experiments performed for measuring material removal rates.

  • PDF

A Research on the Vehicle Detecting Using Earth Magnetic Field Sensor (지자기 센서를 이용한 차량감지 관한 연구)

  • Kang, Moon-Ho;Jeong, Dae-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1239-1241
    • /
    • 2001
  • This research addresses a new vehicle detecting scheme which uses MR(Megneto Resistive) sensor. A vehicle detector which includes two MR sensors for detecting car presence and speed, sensor voltage amplifiers, signal processor, microprocessor, RF data transceiver and a simple car moving simulator is constructed. From experimental results with the vehicle detector the proposed vehicle detecting scheme was verified.

  • PDF

Applicability of a Photosynthetic Ciliate, Mesodinium rubrum MR-MAL01 -Usefulness as a Live Prey Species for the Marine Aquaculture of Bivalves- (광합성 섬모류 Mesodinium rubrum MR-MAL01의 응용성(1) 이매패류 종묘생산을 위한 먹이생물 유용성)

  • 김형섭;명금옥;조수근;이원호
    • Journal of Aquaculture
    • /
    • v.17 no.2
    • /
    • pp.115-121
    • /
    • 2004
  • In a series of feeding experiments using the newly established the first laboratory strain of a temperate photosynthetic ciliate, Mesodinium rubrum MR-MAL01, direct evidence was obtained for ingestion of the cultured M. rubrum cells by the bivalves like the Korean scallop, Chlamys farreri and Manila clam. Ruditapes phil-ippinarum. Each experimental Korean scallop and Manila clam removed up to 9,590 and 23,200 cells min-1, respectively. Small particles almost identical to the ruptured cells of MR-MAL01 culture were observed in the gut of the experimental bivalves, although no intact M. rubrum cell was found. In a 28 days rearing experiment, Isoshrysis galbana (KMCC H-2), a microalga, supported better growth of small Manila clam spat (0.46 mm in shell length) than MR-MAL01 strain. For the large Manila clam spat (0.84 mm in shell length), however. MR-MAL01 strain was a better prey item. Mass culture methods for this photosynthetic marine ciliate may be developed for use as live feed in aquaculture of the spat and broodstock of bivalve and small-mouthed fish larvae.

A Study on the Marker Tracking for Virtual Construction Simulation based Mixed-Reality (융합현실 기반의 가상건설 시뮬레이션을 위한 마커 추적 방식에 관한 연구)

  • Baek, Ji-Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.660-668
    • /
    • 2018
  • The main object of this study was to find a way to operate the marker for simulating a virtual construction using a MR(mixed reality) device. The secondary object was to find a way to extract the form-data from BIM data, and to represent the virtual object by the MR device. A tiny error of scale causes large errors of length because the architectural objects are very large. The scale was affected by the way that the camera of the MR device recognizes the marker. The method of installing and operating the marker causes length errors in the virtual object in the MR system. The experimental results showed that the error factor of the Virtual object's length was 0.47%. In addition, the distance between the markers can be decided through the results of an experiment for the multi-marker tracking system. The minimum distance between markers should be more than 5 m, and the error of length was approximately 23mm. If the represented virtual object must be less than 20mm in error, the particular mark should be installed within a 5 m radius of it. Based on this research, it is expected that utilization of the MR device will increase for the application of virtual construction simulations to construction sites.

Neuro-Fuzzy Modeling Approach for Hybrid Base Isolaton System (하이브리드 면진장치의 뉴로-퍼지 모형화)

  • Kim Hyun-Su;Roschke P. N.;Lee Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.201-208
    • /
    • 2005
  • Neuro-Fuzzy modeling approach is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system consists of friction pendulum systems (FPS) and a magnetorheological (MR) damper. Fuzzy model of the M damper is trained by ANFIS using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses or experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.

  • PDF