• Title/Summary/Keyword: MOTION

Search Result 22,598, Processing Time 0.06 seconds

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Interpretation of C.C.L.Hirschfeld's Theory of Garden Art in Contemporary Meaning and Its Significance (히르시펠트(C.C.L.Hirschfeld) 정원예술론의 의미와 가치의 현대적 해석)

  • Zoh, Kyung-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.58-68
    • /
    • 2014
  • Christian Cay Lorenz Hirschfeld is often regarded as 'a father of landscape garden art.' He was an aesthetics professor and garden theoretician in the $18^{th}$ century. He put forth the most comprehensive garden theory book in five volumes between 1779 and 1785. His book, Theorie der Gartenkunst, was translated and widely circulated in his contemporary. The book, which dealt with diverse aspects of garden art such as history, design, material, and type, urged to promote the prevalence of landscape garden in European continents as well as in Germany. However, there have scarcely been discourses in the Hirschfeld's garden theory. This essay aims to review Hirschfeld's garden thoughts in his book critically and to reinterpret some issues in the contemporary landscape theory and practice. Hirschfeldian theory was the product of $18^{th}$ century German Enlightenment and romanticism. At that time, Nature was regarded as divine realm. There was a German affinity with natural world. The spread of reading culture and the fashion of travel literature were another background of the success of his garden literature. Several issues in Hirschfeld garden theory will discussed here. First, privileging garden art was the most significant contribution in his theory. He emphasized that garden art was the most advanced art form among all art genres. Second, garden art was grounded on the mimesis of nature. The ambiguous relationship between nature and art still existed in garden making. However, garden art can be flourished when utilizing the potency of nature in itself. Third, there was the association between the image and the idea in experiencing the garden. Some garden scenes stimulated the related emotional responses such as cheerful and merry, softly melancholic, romantic, solemn etc. Fourth, the movement was the essential aspect of garden art. Motion and emotion are come together in garden experience. To represent the landscape garden style in suitable way, the sketch or image seems to be preferable than the plans and views. Finally, garden art was composing of not only the physical space but also the spirit of place. He maintained the garden art as hortus moralis should be a social metaphor. Hirschfeldian garden theory has often been criticized as the lack of practical power and the old fashioned idea. However, his theory influenced on formulating the idea of public park in $19^{th}$ century. Moreover, there are still some visionary aspects of his theory such as the reevaluation of garden art, the emphasis of locality and the introduction of Mittelweg idea. Recently, gardening culture are prevalent in various realms of art and life. Hirschfeld's garden theory as humanistic landscape theory can provide us some insights in the contemporary practices.

MANOEUVRABILITIES OF THE M.S. 'SAEBADA' ('새바다호의'의 조종성능에 관한 연구)

  • KIM Ki Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.209-215
    • /
    • 1979
  • The manoeuvrabilities of a ship are decided by the values of her manoeuvring indices. The manoeuvring indices consist of two kinds: indices K and T. The former decides a ship's turning ability and the latter, the length of time delay to a steady turning motion after her rudder has finished the turn of an ordered angle. In this paper, the author figured out the values of the manoeuvring indices of the m. s. 'SAEBADA' (GT: 2,275,7 ton), the training ship of tile National Fisheries University of Busan through her Z test and analyzed these values and the other data which were obtained from her Z test to study her manoeuvrabilities. The results of]tamed are summarized as follows: 1. The manoeuvring indices K' of the m. s. 'SAEBADA' were $1.052(at\;10{\circ}\;Z\;test)\;0.925(at\;20{\circ}\;Z\;test)\;and\;0.877(at\;30{\circ}\;Z\;test)$. Her manoeuvring indices $0.815(at\;10{\circ}\;Z\;test)\;0.502(at\;20{\circ}\;Z\;test)\;and\;0.441(at\;30{\circ}\;Z\;test)$. Her above calculated values K', T' showed that her obeying ability to the turn of her rudder was more increased when her rudder was used to large angle than to small angle, but on the other hand in this case her turning ability was slightly reduced. 2. As it appeared that the calculated K'-values of the m.s. 'SAEBADA' were slightly smaller than the standard K'-values of the fishing boats similar in length, and her overshoot angles at her Z test were greater than other general ships, her turning ability was found to t]e slightly lower. 3. When the m. s. 'SAEBADA' took a turn at her $10^{\circ}\;Z$ test, running distance was about 8.6 times her own length and didn't exceed the standard manoeuvrability distance, 5 to 11 times general ships' own length, therefore she was considered to have a good manoeuvrability synthetically.

  • PDF

An Inquiry into the Formation and Deformation of the Cretaceous Gyeongsang (Kyongsang) Basin, Southeastern Korea (한반도 동남부 백악기 경상분지의 형성과 변형에 관한 질의)

  • Ryu In-Chang;Choi Seon-Gyu;Wee Soo-Meen
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.129-149
    • /
    • 2006
  • Previously published stratigraphic, sedimentologic, paleontologic, paleomagnetic and geophysical data are reviewed to make an understanding on the tectonic evolution of the Cretaceous Gyeongsang (Kyongsang) basin, southeast Korea. A stratigraphic framework and a tectonic model on the formation and deformation of the Gyeongsang Basin are newly proposed on the basis of integration these data with magmatism and mineralization ages in the basin. A newly proposed stratigraphic framework indicates that strata in the basin can be subdivided into five distinct stratigraphic units that represent pre-rifting, syn-rifting, inversion I, II, and III stages. The Gyeongsang Basin was formed initially as a pre-rifting stage due to north-south extension in the Late Jurassic prior to a syn-riftins stage that resulted from east-west extension during the Early Cretaceous. In the Late Cretaceous, the basin was deformed by three-staged sequential deformation of north-south, northwest-southeast, and east-west compressions. The tectonic history of the basin has been largely controlled by the change of motion of the Izanagi Plate from north to northwest during the Cretaceous. In the early Cretaceous, the Izanagi Plate began to subduct northward beneath the Eurasian Plate and caused the left-lateral strike-slip fault systems in the southern part of the peninsula. The left-lateral wrenching of these fault systems was causally linked to development of pull-apart basins, such as the Gyeongsang Basin in the southeastern part of the peninsula. However, northwestward movement of the Izanagi Plate during the Late Cretaceous probably led to the extensive volcanism as well as sequential deformations in the basin. The stratigraphic and tectonic model, which is newly proposed as a result of this study, may be expected to enhancing the efficiency for exploration and exploitation of useful mineral resources in the basin as well as establishing geologic history in the Cretaceous Gyeongsang Basin. Together with the spatial and temporal correlation of the Cretaceous basins in adjacent areas, this stratigraphic and tectonic model provides a new geologic paradigm to delineate the sophisticated tectonic history of East Asia turing the Cretaceous.

The new explore of the animated content using OculusVR - Focusing on the VR platform and killer content - (오큘러스 VR (Oculus VR)를 이용한 애니메이션 콘텐츠의 새로운 모색 - VR 플랫폼과 킬러콘텐츠를 중심으로 -)

  • Lee, Jong-Han
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.197-214
    • /
    • 2016
  • Augmented Reality, virtual reality in recently attracted attention throughout the world. and Mix them mixed reality etc., it has had a significant impact on the overall pop culture beyond the scope of science and technology. The world's leading IT company : Google, Apple, Samsung, Microsoft, Sony, LG is focusing on development of AR, VR technology for the public. The many large and small companies developed VR hardware, VR software, VR content. It does not look that makes a human a human operation in the cognitive experience of certain places or situations or invisible through Specific platforms or program is Encompass a common technique that a realization of the virtual space. In particular, out of the three-dimensional image reveals the limitations of the conventional two-dimensional structure - 180, 360 degree images provided by the subjective and objective symptoms such as vision and sense of time and got participants to select it. VR technology that can significantly induce the commitment and participation is Industry as well as to the general public which leads to the attention of colostrum. It was introduced more than 10 related VR works Year 2015 Sundance Film Festival New Frontier program. The appearance VR content : medical, architecture, shopping, movies, animations. Also, 360 individuals can be produced by the camera / video sharing VR is becoming an interactive tunnel between two possible users. Nevertheless, This confusion of values, moral degeneration and the realization of a virtual space that has been pointed out that the inherent. 4K or HUD, location tracking, motion sensors, processing power, and superior 3D graphics, touch, smell, 4D technology, 3D audio technology - It developed more than ever and possible approaches to reality. Thereafter, This is because the moral degeneration, identity, generational conflict, and escapism concerns. Animation is also seeking costs in this category Reality. Despite the similarities rather it has that image, and may be the reason that the animation is pushed back to the VR content creation. However, it is focused on the game and VR technology and the platform that is entertaining, but also seek new points within the animation staying in the flat Given that eventually consist of visual images is clear that VR sought. Finally, What is the reality created in the virtual space using VR technology could be applied to the animation? So it can be seen that the common interest is research on what methods and means applied.

The Use of Arthroscopic UU Stich for Rotator Cuff Tear and Clinical Results (회전근 개 파열의 관절경하 봉합에서 새로운 봉합 방법의 이용)

  • Ko, Sang-Hun;Shin, Seung-Myeong;Choi, Young-Jin;Cha, Jae-Ryong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: There are various known methods for arthroscopic rotator cuff repair. The purpose of this retrospective study is to report on the clinical results and anatomical results of UU repair surgery, which is a new repair method. Materials and Methods: We enrolled 156 patients (88 men and 68 women) who underwent UU repair for rotator cuff tears from January 2009 to May 2010 in our hospital. Their average age was 55 years old (range: 38~75 years old) and the average follow-up period was 12 months (range: 6~23 months). For determining the results, we evaluated the VAS for pain, the daily living index (ADL) in the ASES scores, the UCLA and KSS scores, and all these tests were conducted at the first hospital visit and 6 months and 1 year after surgery and at the final follow-up. During the follow-up period, MRI was performed 3 and 6 months after surgery only in the patients who consented to MRI scans to confirm the presence of re-rupture. Results: The average scores of the VAS as a pain indicator decreased from 7.0 before surgery to 2.7 after surgery (p<0.05). The UCLA and KSS scores increased from 22.2 to 32.5 and from 83.7 to 91.5, and the changes was significant (p<0.05). For the active joint range of motion, the average forward flexion was improved from 125 to 175 degrees, the average lateral external rotation was improved from 38 to 58 degrees, and the average abduction was improved from 104 to 169 degrees. Out of a total of 156 patients, re-rupture was observed in 4 cases (3%) of 117 cases (75%) for which MRI was performed (with consent) between 3 and 6 months after surgery. Conclusion: UU repair surgery as arthroscopic repair of rotator cuff tear is a good repair method that shows excellent clinical results and a low re-rupture rate.

Percutaneous Mini-open Reduction for Mason II or III Radial Head and Neck Fracture (요골 두 및 경부 골절의 경피적 도수 정복술)

  • Lee, Jeong-Gil;Koh, Il-Hyun;Kim, Hyung-Sik;Choi, Yun-Rak;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.230-236
    • /
    • 2010
  • Purpose: We wanted to evaluate the result of percutaneous, mini-open reduction for the treatment of Mason II or III radial head and neck fractures. Materials and Methods: 13 patients (8 male, 5 female) with Mason II or III radial head and neck fractures were treated by 1 cm percutaneous mini-open reduction under fluoroscopy. The average age of our subjects was 29 years. Follow up duration was 18 months. Results: Union was noted in all cases. Mean radial neck angulation was decreased from 33.2 degrees to 7.8 degrees. The mean change in angulation between the immediate post-operative and last follow-up was 0.7 degrees. The mean range of motion at the elbow joint was at last follow up, 133.1 degrees in flexion, 7.3 degrees in extension, 80 degrees in pronation and 84.3 degrees in supination. Postoperatively, mean Mayo Elbow Performance Index, American Shoulder and Elbow Surgeons elbow score, and Disabilities of the Arm, Shoulder and Hand score were 96.2, 97 and 1.2. Temporary posterior interosseous nerve palsy (1 case) and minimal cubitus valgus deformity (1 case) were noted. Conclusion: Selected Mason II or III radial head and neck fractures can be treated satisfactorily with percutaneous mini-open reduction.

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF

Prophylactic Radiotherapy to Prevent the Recurrence of Heterotopic Ossification after Surgical Intervention of the Elbow (주관절에서 이소성 골형성의 재발방지를 위한 예방적 방사선 치료)

  • Kim, Hak-Jae;Kim, Jin-Ho;Kim, Kyu-Bo;Choi, Ja-Young;Chung, Moon-Sang;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • Purpose: Heterotopic ossification is a well-known postoperative and post-traumatic complication of the elbow. We reviewed the treatment outcome for the use of low-dose radiation after surgical intervention of the elbow to prevent recurrence of heterotopic ossification (HO). Materials and Methods: Forty-five patients with HO underwent surgical intervention and postoperative radiotherapy of the elbow. The median age of the patients was 29 years ($16{\sim}75$ years), and 27 of the patients were men and 18 were women. The occurrence of HO was mainly due to surgery after fracture (24/45) and traumatic injury (21/45). Limitation of the range of motion (ROM) was the most common symptom of the patients. Thirty-four patients received postoperative radiotherapy with a dose of 8 Gy in 2 fractions; 5 patients received a dose of 10 Gy in 5 fractions and 6 patients received a dose of 7 Gy in 1 fraction. Postoperative radiotherapy was given on the first two postoperative days for most of the patients. Sixteen patients were not given anti-inflammatory medication and 29 patients were given NSAIDs for $1{\sim}8$ months. Results: After a median follow-up period of 18 months (range $6{\sim}72$ months), 41 patients showed clinical improvement and two patients did not show improvement. Assessment of the ROM showed a mean improvement from $0{\sim}135^{\circ}$ to $60{\sim}145^{\circ}$ (p=0.028), and assessment of the functional outcome according to MEPI was from ($15{\sim}95$) to ($80{\sim}100$) (p<0.0001). Two of the 34 patients that were followed-up with radiography had mild radiological recurrence of heterotopic ossification. No complications were observed after the radiotherapy. Conclusion: These results suggested that low-dose radiation administered after surgical intervention is safe and effective to prevent the recurrence of HO in the elbow.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF