• Title/Summary/Keyword: MONITORING TECHNIQUE

Search Result 2,200, Processing Time 0.038 seconds

Simultaneous Pesticide Analysis Method for Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor and Trifluralin Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor 및 Trifluralin의 동시 분석)

  • Ahn, Kyung Geun;Kim, Gi Ppeum;Hwang, Young Sun;Kang, In Kyu;Lee, Young Deuk;Choung, Myoung Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.104-116
    • /
    • 2018
  • BACKGROUND: This experiment was conducted to establish a simultaneous analysis method for 7 kinds of herbicides in 3 different classes having similar physicochemical property as diphenyl ether(bifenox and oxyfluorfen), dinitroaniline (ethalfluralin and trifluralin), and chloroacetamide (metolachlor, pretilachlor, and thenylchlor) in crops using GC-ECD/MS. METHODS AND RESULTS: All the 7 pesticide residues were extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice and soybean. The extract was diluted with saline water and directly partitioned into n-hexane/dichloromethane(80/20, v/v) to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. The analytes were separated and quantitated by GLC with ECD using a DB-1 capillary column. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop samples fortified with bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries of the 7 pesticide residues ranged from 75.7 to 114.8% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of the analytes were 0.004 (etahlfluralin and trifluralin), 0.008 (metolachlor and pretilachlor), 0.006 (thenylchlor), 0.002 (oxyfluorfen), and 0.02 (bifenox) mg/kg as verified by the recovery experiment. A confirmatory technique using GC/MS with selected-ion monitoring was also provided to clearly identify the suspected residues. Therefore, this analytical method was reproducible and sensitive enough to determine the residues of bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin in agricultural commodities.

Field research of cultivation technique for stable production of common mushroom(Agaricus bisporus) (양송이 안정생산을 위한 생산기술 현장연구)

  • Jhune, Chang-Sung;Jang, Kab-Yeul;Jeong, Jong-Cheon;Lee, Chan-Jung;Kong, Won-Sik;Yoo, Young-Bok
    • Journal of Mushroom
    • /
    • v.8 no.3
    • /
    • pp.122-130
    • /
    • 2010
  • Common mushroom production per area has been decreased and are up to less than 50% of the 1980 production. To determine the main reasons for the decrement, we performed this study. Two main reasons, which are mushroom disease and the low compost quality because of mechanized compost making, were assessed. In mechanized mushroom farms, nitrogen concentration in compost was lower than recommended and total compost quantity was about 100-150 $kg/3.3m^2$, which was also lower than usual. Our study revealed that higher nitrogen concentration (about 1.5%) in compost gave better production. Also, use of large amount of compost appeared to increase the mushroom production, although more insects and disease problems were observed. The relationships between the presences of microorganisms and occurrence of diseases were assessed by monitoring the microorganism densities near the mushroom farms. Higher number of microorganisms were observed near the mushroom farm area, compared to control region, Daechon beach. Most contaminating molds were found in the circulating fans, tunnel and culture room floor. The bacterial isolates were collected from the air in mushroom culture room and killed with 0.005% Benzalkonium solution, indicating treatment of Benzalkonium are the effective methods to sanitize the mushroom culture room.

  • PDF

Evaluation of Movement Pattern of Erythroculter erythropterus Inhabit in the Mid-lower Part of Nakdong River Using Acoustic Telemetry (낙동강 중.하류 구간에서 수중 음향측정방식을 이용한 강준치의 이동성 평가)

  • Yoon, Ju-Duk;Kim, Jeong-Hui;In, Dong-Su;Yu, Jae Jeong;Hur, Moonsuk;Chang, Kwang-Hyeon;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.403-411
    • /
    • 2012
  • Acoustic telemetry is used to obtain a relatively continuous record of fish movement. This method has several advantages for studying migrating fish populations that are moving from large rivers. The Nakdong River is the longest river in South Korea and the main stream has faced a change, which consists of the installation of the large weirs. In this study, we applied acoustic telemetry to monitor the movement pattern of Erythroculter erythropterus (family Cyprinidae) and identified home range and movement distance in the Nakdong River. A total of fourteen individuals were released at three different locations and around 80 km section from the estuary barrage was investigated. Eight individuals were tagged and released at estuary barrage (N02) utilized up to 15.9 km (home range) upstream from the release site as home range. Four individuals were tagged and released at Samrangjin (N07), most fish moved and stayed within 9.7 km (home range) downstream area, except E12, which did not show any movement. Two individuals were tagged and released at Changnyeong-Haman weir (N10), and all individuals migrated downstream from the release site. Especially, E14 recorded the longest accumulated detected distance, 36.7 km downstream during 32 days after release. There was no correlation identified between movement (accumulated detected distance and home range) and standard length (Spearman rank correlation, p>0.05). Although, this technique could be an available method to monitor behavior and ecology of freshwater fish effectively, increment of number of receivers and tags are required for more detailed results of fish migration.

The Effect of Midazolam As Sedative Agent in Bronchoscopy (기관지내시경 검사시 전처치로서 Midazolam의 효과)

  • Lee, Sang-Haak;Hyun, Dae-Sing;Lee, Sook-Young;Kim, Seok-Chan;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.612-618
    • /
    • 2002
  • Background : Bronchoscopy is an important diagnostic and a therapeutic tool in chest medicine. However, most patients feel that a bronchoscopy is an unpleasant procedure, and it is important to sedate the patients appropriately, particularly where repetitive examinations are required. Midazolam is a sedative drug with amnestic qualities and a rapid 2 hour half-life. This study have attempted to determine the safety, appropriate dosage, and the effect of midazolam premedication in patients who underwent a bronchoscopy. Methods : One hundred and eighty consecutive patients undergoing bronchoscopy were enrolled in this study. The patients received a midzolam doses of 0.03 mg/kg, 0.06 mg/kg, or a placebo. An additional dose of lidocaine, the total number of coughs, and the duration of the procedures were recorded with monitoring the the blood pressure, heart rate, and oxygen saturation. The level of satisfaction was assessed by the patient, bronchoscopist, and the nurse. Results : The blood pressure, pulse rates, oxygen saturation, number of coughs, lidocaine dose, and procedure time in the 3 groups were similar. There was a trend for the midazolam 0.03 mg/kg group to satisfy bronchoscopists more than the other two groups. The nurses' acceptability was lower in the midazolam 0.06 mg/kg group than the other groups. The patients' acceptablity was greater in both the midazolam 0.03 mg/kg and 0.06 mg/kg groups than in the control group. Conclusion : Sedation with low doses of intravenous midazolam is a safe technique for fiberoptic bronchoscopy with a low morbidity and high acceptable to patients and bronchoscopists.

Development of the evaluation tool for the food safety and nutrition management education projects targeting the middle class elderly: Application of the balanced score card and the structure-process-outcome concept (중산층 노인대상 식품안전·영양관리 교육 사업 평가를 위한 도구 개발: 균형성과표와 구조·과정·성과 개념 적용)

  • Chang, Hyeja;Yoo, Hyoi;Chung, Harim;Lee, Hyesang;Lee, Minjune;Lee, Kyungeun;Yoo, Changhee;Choi, Junghwa;Lee, Nayoung;Kwak, Tongkyung
    • Journal of Nutrition and Health
    • /
    • v.48 no.6
    • /
    • pp.542-557
    • /
    • 2015
  • Purpose: The aim of this study is to develop an evaluation tool for operation of food safety and nutrition education projects for middle class elderly using the concept of the balanced score card. Methods: After the draft of the evaluation tool for the elderly training projects was completed, it was revised into the questionnaire and the validity of the indicators was tested by the Delphi group. The validity of the indicators was rated using a 5-point scale. The Delphi group consisted of 26 experts in the education sector, 16 government officials, and 24 professionals of the related area in communities. The first round test was conducted from July 9 to July 17, 2012, and 45 persons responded. The second round test was conducted from July 18 to July 25 and 32 persons responded. Results: The indicators, which were answered by more than 75 percent of the experts as 'agree' (4 points), 'strongly agree' (5 point) were included as the final indicators for the evaluation tool: 28 items out of 36 in outcome perspectives, 9 items out of 12 in process perspectives, and 17 out of 20 items in structure perspectives. The score was allocated as 50 points for outcome indicators, 20 points for process indicators, and 30 points for structure indicators. Conclusion: Completion of the evaluation tool is a prerequisite to determine whether the program is effectively implemented. The monitoring tool developed in the study could be applied for identification of the most optimal delivery path for the food safety and nutrition education program, for the spread of the food safety and nutrition education program for middle class elderly.

A Criteria on Nitrate Concentration in Soil Solution and Leaf Petiole Juice for Fertigation of Cucumber (Cucumis sativus L.) under Greenhouse Cultivation (시설 오이의 관비재배를 위한 토양용액과 엽병즙액중 질산태 농도 기준 설정)

  • Lim, Jae-Hyun;Lee, In-Bog;Kim, Hong-Lim
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2001
  • To develope a technique for efficiently managing fertilizer for cucumber, a quick test method to quantify nitrate content in soil solution and leaf petiole juice using a simple instrument was investigated. Among the nitrate analyzing instruments such as compact ion meter, nitrate ion meter, and test strip with reflectometer, the paper test-strip used in conjunction with a hand-held reflectometer was most closely correlated with ion chromatography method in nitrate content, and then it would be suggested with a tool that a farmer can use rapidly, conveniently and accurately for nitrate analysis in a field. Nitrate content in soil solution collected by porous cup was very variable on the lapsed time after drip irrigation and the sampling positions such as soil depth and the distance from dripper. As a result, a significant correlation between nitrate contents of soil solutions and 2M KCl soil extract was not found. However, nitrate content in soil solution extracted with a volume basis (soil:water=1:2) showed the highly significant correlation with that in 2M KCl extract. Nitrate contents of cucumber leaf petiole juices was greatly different between upper and lower leaves. Eleven to sixteen positioned-leaf would be a proper sampling position to determine nitrate content in leaf petiole for evaluating nutrient state by plant tissue analysis. From the secondary regression equations between nitrate contents of soil and petiole juice and the yield of cucumber, nitrate levels for real time diagnosis were estimated as $400mg\;l^{-1}$ soil solution by porous cup. $300mg\;l^{-1}$ in a soil volume extraction, and $1400mg\;l^{-1}$ in petiole juice from spring to summer season. In addition, the maximum yield of cucumber fruit in pot test was obtained in nitrate $1500mg\;l^{-1}$ level of petiole juice, which was similar to nitrate $1400mg\;l^{-1}$ in greenhouse trial.

  • PDF

Clinical Application of Compressed Spectral Array During Deep Hypothermia (초저체온하 대동맥수술 환자에서 완전 순환차단의 안전한 체온 및 기간에 대한 연구 - 뇌파 Compressed Spectral Array의 임상적 응용 -)

  • 장병철;유선국
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.752-759
    • /
    • 1997
  • Profound hypothermia protects . cerebral function during total circulatory arrest(TCA) in the surgical treatment of a variety of cardiac and aortic diseases. Despite its importance, there is no ideal technique to monitor the brain injury from ischemia. Since 1994, we have developed compressed spectral array(CSA) of electroencephalography(EEG) and monitored cerebral activity to reduce ischemic injury. The purposes of this study are to analyse the efficacy of CSA and to establish objective criteria to consistently identify the safe level of temperature and arrest time. We studied 6 patients with aortic dissection(AD, n=3) or aortic arch aneurysm(n=3, ruptured in 2). Body temperatures from rectum and esophagus and the EEG were monitored continuously during cooling and rewarming period. TCA with cerebral ischemia was performed in 3 patients and TCA with selective cerebral perfusion was performed in 3 patients. Total ischemic time was 30, 36 and 56 minutes respectively for TCA group and selective perfusion time was 41, 56 and 92 minutes respectively for selective perfusion group. The rectal temperatures for flat EEG were between 16.1 and 22. $1^{\circ}C$ (mean: 18.4 $\pm$ 2.0): the esophageal temperatures between 12.7 and $16.4^{\circ}C$ (mean $14.7\pm1.6).$ The temperatures at which EEG reappeared $5~15.4^{\circ}C$ for esophagus. There was no neurological defic t and no surgical mortality in this series. In summary, the electrical cerebral activity Teappeared within 23 minutes at the temperature less than $16^{\circ}C$ for rectum. It seemed that $15^{\circ}C$ of esophageal temperature was not safe for 20 minutes of TCA and continuous monitoring the EEG with CSA to identify the electrocerebral silence was useful.

  • PDF

Analysis of the growth environment and fruiting body quality of Pleurotus eryngii cultivated by Smart Farming (큰느타리(새송이)버섯 스마트팜 재배를 통한 생육환경 분석 및 자실체 품질 특성)

  • Kim, Kil-Ja;Kim, Da-Mi;An, Ho-Sub;Choi, Jin-Kyung;Kim, Seon-Gon
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.211-217
    • /
    • 2019
  • Currently, cultivation of mushrooms using the Information and Communication Technology (ICT)-based smart farming technique is increasing rapidly. The main environmental factors for growth of mushrooms are temperature, humidity, carbon dioxide (CO2), and light. Among all the mentioned factors, currently, only temperature has been maintained under automatic control. However, humidity and ventilation are controlled using a timer, based on technical experience.Therefore, in this study, a Pleurotus eryngii first-generation smart farm model was set up that can automatically control temperature, humidity, and ventilation. After installing the environmental control system and the monitoring device, the environmental condition of the mushroom cultivation room and the growth of the fruiting bodies were studied. The data thus obtained was compared to that obtained using the conventional cultivation method.In farm A, the temperature during the primordia formation stage was about 17℃, and was maintained at approximately 16℃ during the fruiting stage. The humidity was initially maintained at 95%, and the farm was not humidified after the primordia formation stage. There was no sensor for CO2 management, and the system was ventilated as required by observing the shape of the pileus and the stipe. It was observed that, the concentration of CO2 was between 700 and 2,500 ppm during the growth period. The average weight of the mushrooms produced in farm A was 125 g, and the quality was between that of the premium and the first grade.In farm B. The CO2 sensor was in use for measurement purposes only; the system was ventilated as required by observing the shape of the pileus and the stipe. During the growth period, the CO2 concentration was observed to be between 640 and 4,500 ppm. The average weight of the mushrooms produced in farm B was 102 g.These results indicate that the quality of the king oyster mushroom is determined by the environmental conditions, especially by the concentration of CO2. Thus, the data obtained in this study can be used as an optimal smart farm model, where, by improving the environmental control method of farm A, better quality mushrooms were obtained.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.