Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Evaluation of Image Quality using Monte Carlo Simulation in Digital Mammography System (디지털유방영상시스템에서 몬테카를로 시뮬레이션을 이용한 영상평가)

  • Kim, Changsoo;Kang, Se-Sik;Kim, Jung-Hoon;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.247-254
    • /
    • 2014
  • For the purpose of early diagnosis of the breast cancer, the attention on the screening mammography has been increasing-with supply of digital mammography day by day. Image quality is decided by target materials and filter combinations. Optimized selection by a glandular density and a thickness is needed, because these combinations change x-ray spectrum and effect to image quality. The purpose of this study is to find out optimized target and filter combinations through the evaluation of quantitative image quality and to suggest means which minimize patient dose through MCNPX. In results, spatial frequency resolution evaluation which is quantitative image quality evaluation method, MTF, NPS, DQE shows that we have to select Mo/Mo combinations or Mo/Rh combinations when compressed breast is thin. but in case of that when compressed breast is thick, we have to select Rh/Rh combinations or W /Rh combinations. In a comprehensive evaluation, W!Rh combinations which are not used in thin breasts in practice was superior to all image quality evaluation. This result is somewhat different-with clinical examination results. Secondary end point was organ dose evaluation, radiation dose of opposite breast was approximately 47 ~73% effectiveness when selecting standard breast. In conculsion, the most important point is that we have to select the optimal combinations-with considering dose evaluation and various thickness.

Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography (유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰)

  • Yang, Han-Jun;Joo, Mi-Hwa;Ko, Sin-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.113-119
    • /
    • 2007
  • It is important to consider the contrast of object in Mammography because an absorption gap between tissues of body and breast in breast is low. This study is to evaluate MTF image with resolution chart according to change of combination of target and filter. The results were as follows : 1. There were significant differences in X-ray energy according to combination of filter(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al) and acrylic thickness(2 cm, 3 cm, 4 cm). 2. The value of lp/mm on MTF to 0.5 showed that the sharpness in MTF curve was 2.4 compared to Mo/Mo and 2cm acryl, 2.63 in Mo/Rh and 4 cm acryl, and 2.9 in Rh/Rh and 6cm acryl. 3. The value of lp/mm on MTF showed that the resolution in MTF curve was 6.0 compared to Mo/Mo and 2 cm acryl, 4.60 in Rh/Al and 4cm acryl, and 6.03 in Rh/Al and 6 cm acryl. 4. The value of MTF on 2.5 lp/mm distinguishable visually was 0.48 compared to Mo/Mo and 2 cm acryl, 0.53 in Mo/Rh and 4cm acryl, and 0.59 in Rh/Rh and 6cm acryl. 5. For the evaluation of an image of the mammo-phantom, the score of Mo/Mo was 12 points, Mo/Rh 11, Rh/Rh 10.5, Mo/Al 10, Rh/Al 9.0, respectively.

  • PDF

Improving Chest X-ray Image Classification via Integration of Self-Supervised Learning and Machine Learning Algorithms

  • Tri-Thuc Vo;Thanh-Nghi Do
    • Journal of information and communication convergence engineering
    • /
    • v.22 no.2
    • /
    • pp.165-171
    • /
    • 2024
  • In this study, we present a novel approach for enhancing chest X-ray image classification (normal, Covid-19, edema, mass nodules, and pneumothorax) by combining contrastive learning and machine learning algorithms. A vast amount of unlabeled data was leveraged to learn representations so that data efficiency is improved as a means of addressing the limited availability of labeled data in X-ray images. Our approach involves training classification algorithms using the extracted features from a linear fine-tuned Momentum Contrast (MoCo) model. The MoCo architecture with a Resnet34, Resnet50, or Resnet101 backbone is trained to learn features from unlabeled data. Instead of only fine-tuning the linear classifier layer on the MoCopretrained model, we propose training nonlinear classifiers as substitutes for softmax in deep networks. The empirical results show that while the linear fine-tuned ImageNet-pretrained models achieved the highest accuracy of only 82.9% and the linear fine-tuned MoCo-pretrained models an increased highest accuracy of 84.8%, our proposed method offered a significant improvement and achieved the highest accuracy of 87.9%.

Manufactures of dental casting Co-Cr-Mo based alloys in addition to Sn, Cu and analysis of infrared thermal image for melting process of its alloys (Sn 및 Cu를 첨가한 치과 주조용 Co-Cr-Mo계 합금제조 및 용해과정 분석)

  • Kang, Hoo-Won;Park, Young-Sik;Hwang, In;Lee, Chang-Ho;Heo, Yong;Won, Yong-Gwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.141-147
    • /
    • 2014
  • Purpose: Dental casting #Gr I (Co-25Cr-5Mo-3Sn-1Mn-1Si), #Gr II (Co-25Cr-5Mo-5Cu-1Mn -1Si) and #Gr III (Co-25Cr-5Mo-3Sn-5Cu-1Mn-1Si) master alloys of granule type were manufactured the same as manufacturing processes for dental casting Ni-Cr and Co-Cr-Mo based alloys of ingot type. These alloys were analyzed melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: These alloys were manufactured such as; alloy design, the first master alloy manufatured using vacuum arc casting machine, melting metal setting in crucible, melting in VIM, pouring in the mold of bar type, cutting the gate and runner bar and polishing. These alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer indicated alloys in the crucible were set and operated. Results: The melting temperatures of these alloys measuring infrared thermal image analyzer were decreased in comparison with remanium$^{(R)}$ GM 800+, vera PDI$^{TM}$, Biosil$^{(R)}$ f, WISIL$^{(R)}$ M type V, Ticonium 2000 alloys of ingot type and vera PDS$^{TM}$(Aabadent, USA), Regalloy alloys of shot type. Conclusion: Co-Cr-Mo based alloy in addition to Sn(#Gr I alloy) were decreased the melting temperature with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer.

Observation of Fatigue Crack Growth Behavior in 1Cr-1Mo-0.25V Steel Using Image Processing Technology (영상처리기법을 이용한 1Cr-1Mo-0.25V 강의 피로균열 성장거동 관찰)

  • Nahm, Seung-Hoon;Kim, Yong-Il;Ryu, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.14-21
    • /
    • 2002
  • The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using an image processing software which was developed by authors. Various image processing techniques like a block matching method was applied tc the detection of surface fatigue cracks. By comparing the data measured by the image processing system with those by the manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced.

Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine (치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석)

  • Kang, Hoo-Won;Park, Young-Sik;Hwang, In;Lee, Chang-Ho;Heo, Yong;Won, Yong-Gwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

Data processing technique for data measured in MO image measurement system

  • Lee, Wongi;Lee, Hyoyeon;Yoo, Jaeun;Youm, Dojun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2013
  • We report processing technique in the MO image measurement system. Calibration procedure is not only considered to perpendicular field but also in-plane field. Current density and field profiles are obtained by Biot-savart law and inversion method. We show example of $(Gd,Y)_1Ba_2Cu_3O_{7-{\delta}}-BaZrO_3$ film that have tilted nano rod pinning centers about $13^{\circ}$ from the c-axis.

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.