• Title/Summary/Keyword: MM5-A2C

Search Result 3,277, Processing Time 0.05 seconds

Relationship Between Insertion Torque, and Pullout Strength Depending on the Size of the Pilot Hole and Biodegradable Suture Anchor in Osteoporotic Humeral Head (골다공증이 있는 상완골 골두의 파일럿 홀 (Pilot Hole)과 흡수성 나사못의 크기에 따른 토크 (Torque)와 뽑힘 강도 (Pullout Strength) 간의 관계)

  • Chun, Yong-Min;Lee, Young-Han;Kim, Sung-Hwan;Park, Yoo-Jung;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.8-15
    • /
    • 2012
  • Purpose: The object of this study was to investigate the difference in torque and pullout strength between the standard anchor insertion (5.0 mm) with a small awl (3.7 mm) and larger anchor insertion (6.5 mm), with a standard awl (5.0 mm) in osteoporotic humeral head. Materials and Methods: The embalmed 24 paired cadaveric shoulders were assigned to either Group A or B. After measuring the bone mineral density (BMD) of the ROI (region of interest) in the humeral head, 5.0 mm suture anchors were inserted using a 3.7 mm awl in Group A1, and the same 5.0 mm anchors were inserted using a 5.0 mm awl in Group A2. The 5.0 mm anchors were inserted using a 5.0 mm awl in Group B1, and 6.5 mm anchors were inserted using a 5.0 mm awl in Group B2. We measured the torques at the time of the anchor insertion and pullout strengths. Results: There was no significant difference in the BMD between the groups. The torque of A1 (20.6 $cN{\cdot}m$) was significantly higher than that of A2 (13.2 $cN{\cdot}m$), and the torque of B2 (20.8 $cN{\cdot}m$) was significantly higher than that of B1(12.1 $cN{\cdot}m$). However, the difference in the increased torque between group A and B was not significant. The pullout strength of A1 (204.2 N) was significantly higher than that of A2 (152.9 N), and the pullout strength of B2 (210.9 N) was significantly higher than that of B1 (149.5 N). However, the difference in the increased pullout strength between Group A and B was not significant. Conclusion: In severe osteoporosis, the use of a larger suture anchor with a standard awl increased the torque and pullout strength significantly, in comparison to the use of the same sized suture anchor and awl. If there is an inadequate interval between the anchors on the greater tuberosity, the use of a 3.7 mm awl and 5.0 mm anchor will be beneficial compared to that of a 5.0 mm awl and 6.5 mm anchor, considering that an increase in the pullout strength does not depend on the awl size.

Descriptions of Four New Species of Predatory Nematodes (Mononchida) From Korea (韓國産 捕食線蟲(Mononchida: Nematoda)의 4 新種 기재)

  • Choi, Young-Eoun;Khan, Zakaullah;Lee, Sung-Min
    • The Korean Journal of Soil Zoology
    • /
    • v.4 no.2
    • /
    • pp.89-100
    • /
    • 1999
  • Four new and a known spacies of the order Mononchida were described and illustrated. Iotonchus obtusus sp. n. was 2.8 mm long, a=33, b=4.2, c=61, V=68%, buccal cavity=61${\times}$45 mm, and is characterized by having basally situated dorsal tooth, presence of vulval papillae and in having short, hemispherical tail with thick cuticle at terminus. Miconchus vulvapapillatum sp. . was 2.7-3.6 mm long, a=29-36, b=4.1-4.5, c=18.4-21, V=65-69%, buccal cavity=53-61${\times}$29-33 mm, spicules=132-137 mm, ventromedian supplements 28-31, and was characterized by having 5-8 pre- and post vulval papillae in contiguous series, and three pairs of vulval glands. Clarkus koreanus sp. n. was 1.1-1.3 mm long, a=27.5-28.8, b=3.5-3.9, c=12-14.5, V=60-64%, buccal cavity=24-28${\times}$13.5-15 mm, and was characterized by well offset lip region, amphids situated well below to dorsal tooth apex, and vulva elevated, with vulval flap. Coomansus ulsani sp. n. was 1.2-1.5 mm long, a=23.5-26, b=3.4-3.8, c=13.6-14.8, V=65-68%, buccal cavity=36-39${\times}$21-23 mm and was characterized by well offset lip region and a thin longitudinal ridge on vertical walls of stoma.

  • PDF

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

Anatomic Feasibility of Posterior Cervical Pedicle Screw Placement in Children : Computerized Tomographic Analysis of Children Under 10 Years Old

  • Lee, HoJin;Hong, Jae Taek;Kim, Il Sup;Kim, Moon Suk;Sung, Jae Hoon;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.6
    • /
    • pp.475-481
    • /
    • 2014
  • Objective : To evaluate the anatomical feasibility of 3.5 mm screw into the cervical spine in the pediatric population and to establish useful guidelines for their placement. Methods : A total of 37 cervical spine computerized tomography scans (24 boys and 13 girls) were included in this study. All patients were younger than 10 years of age at the time of evaluation for the period of 2007-2011. Results : For the C1 screw placement, entry point height (EPH) was the most restrictive factor (47.3% patients were larger than 3.5 mm). All C2 lamina had a height larger than 3.5 mm and 68.8% (51/74) of C2 lamina had a width thicker than 3.5 mm. For C2 pedicle width, 55.4% (41/74) of cases were larger than 3.5 mm, while 58.1% (43/74) of pedicle heights were larger than 3.5 mm. For pedicle width of subaxial spine, 75.7% (C3), 73% (C4), 82.4% (C5), 89.2% (C6), and 98.1% (C7, 1/54) were greater than 3.5 mm. Mean lamina width of subaxial cervical spine was 3.1 (C3), 2.7 (C4), 2.9 (C5), 3.8 (C6), and 4.0 mm (C7), respectively. Only 34.6% (127/370) of subaxial (C3-7) lamina thickness were greater than 3.5 mm. Mean length of lateral mass for the lateral mass screw placement was 9.28 (C3), 9.08 (C4), 8.81 (C5), 8.98 (C6), and 10.38 mm (C7). Conclusion : C1 lateral mass fixation could be limited by the morphometrics of lateral mass height. C2 translamina approach is preferable to C2 pedicle screw fixation. In subaxial spines, pedicle screw placement was preferable to trans-lamina screw placement, except at C7.

Morphological Characteristics, Developmental Period, Seasonal Occurrence, and Sweetpotato Consumption of Aedia leucomelas (L.) (Lepidoptera Noctuidae) (뒷날개흰밤나방(Aedia leucomelas)의 형태적 특징, 온도별 발육기간, 발생소장 및 고구마 섭식량)

  • 이건휘;백채운;김두호;최만영;나승용;김상수
    • Korean journal of applied entomology
    • /
    • v.42 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Morphological characteristics, developmental period, and seasonal occurrence of Adeia leucomelas (L.) were investigated from 1999 to 2000. In addition, consumption of sweetpotato as food was also examined. Adults of A. leucomelas were dark-brown and body lengths of females and males were 20.2 mm and 18.9 mm, respectively, Wing expanse of female and male was 33.7 mm and 29.4mm, respectively. Egg was flat round-shape. Larva was light yellow-green to dark-brown with 3.3-53.5 mm. Pupa was deep-brown and 15.1 mm in length. Developmental periods of A. leucomelas from egg to adult emergence at different temperatures of 15, 20, 25, and 30$^{\circ}$C were 108.5, 70.7, 40.2, and 29.1 days, respectively, Developmental threshold (DT) and effective accumulative temperatures were estimated as 10.7$^{\circ}$C and 67.5 DD in egg stage, 11.0$^{\circ}$C and 275.1 DD in larval stage and 9.3$^{\circ}$C and 244.6 DD in pupal stage, respectively. The longevity of adult female was shortened with increment of temperature, whereas the total numbers of eggs laid by a female were increased. The larvae of A.leucomelas occurred from mid-June to early October, and population reached its peak during early to mid-September in Jeonbuk province. Food consumption of A. leucomelas was highest at 20-25$^{\circ}$C. Food consumption of 1 st, 2nd, 3rd, 4th, and 5th larvae of A. leucomelas per day at 25$^{\circ}$C was 0.4, 3.6, 19.6, 40.7, and 78.9 $\textrm{cm}^2$, respectively.

Experimental Study for Evaporation Heat Transfer and Pressure Drop of R-22 and R-407C in an Inner Diameter of 4.3 mm and 6.4 mm (내경 4.3 mm와 6.4 mm관내 R-22와 R-407C의 증발 열전달과 압력강하에 관한 실험연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in horizontal copper tubes were investigated experimentally. The main components of therefrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 4.3 mm and 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^2s]$ and the saturation temperature of evaporator were 5 [$^{\circ}C$]. The evaporation heat transfer coefficients of R-22 and R-407C rise with the increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 for inner diameter tube of 4.3 mm and 6.4 mm is about $7.3{\sim}47.1%$ and $5.68{\sim}46.6%$ higher than that of R-407C, respectively.

  • PDF

Optimization of Manufacturing Condition for Fried Garlic Flake and the Physicochemical Properties (튀긴 마늘 flake 제조조건의 최적화 및 이화학적 특성)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • Korean journal of food and cookery science
    • /
    • v.28 no.6
    • /
    • pp.805-811
    • /
    • 2012
  • This study was carried out in order to optimize the manufacturing condition of fried garlic flakes as well as to investigate the physicochemical properties of the flakes. Fried garlic flake samples were prepared as follows: garlic was sliced by a thickness of 1.5 mm, 2.0 mm, 2.5 mm, which were measured by a thickness gage. The samples were fried in vegetable oil under different temperatures of $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$. The compression strength depending on the height (h) was measured in order to find the thickness effect by the rheometer (force control: 50 N, h: 3.25 mm). Moreover, the sample with 1.5 mm thickness showed crisp phenomena of the split compared with the crush shape of the 2.0 mm and 2.5 mm thick samples. The result of strength for time dependence showed a sample with a thickness of 1.5 mm, which was measured 5~9 times more than the 2.0 mm and 2.5 mm thick samples. We thought the reason that the 1.5 mm sample had less response power equivalent to compression force than the other samples. Alliin has been found to affect the immune responses in the blood, it is a derivative of the amino acid cysteine and is also quite heat stable. The LC system with a UV detection at 210 nm consists of a separation on a Zorbax TMS column and isocratic elution with water and ACN as a mobile phase. The alliin contents of raw and fried garlic flake under $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$ were 18.10 mg/mL, 14.0 mg/mL, 11.6 mg/mL and 11.1 mg/mL, respectively. The decrement of alliin content under different temperature was a small quantity hence, we confirmed that the increasing manufacturing temperature was not affected by the alliin content. Examining for the particle structure of fried garlic flakes by a polarization microscope, the color of the sample treated at $160{\sim}170^{\circ}C$ was pure yellow. Furder, the fiber shaped particle, which has an effect on the tough texture, almost did not appear compared to the different temperature conditions. Finally, the sensory test for the preference of fried garlic flake under different conditions was carried out and the scores for various sensory characteristics were surveyed. According to the physicochemical measurements and sensory evaluation, we confirmed that the optimum manufacturing condition of fried garlic flake was 1.5 mm thick at a temperature of $160{\sim}170^{\circ}C$.

RELATIONSHIP OF THE MAXILLARY CUSPID AND ALA-LACRIMAL DUCT LINE (정상인(正常人)에 있어서의 상악(上顎) 견치(犬齒)와 비익(鼻翼) 및 누관(淚管)과의 위치적(位置的) 관계(關係))

  • Jhin, Chang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.35-40
    • /
    • 1976
  • The author observed the positional relationship of maxillary cuspid to ala-lacrimal duct line in the 594 Koreans(329 male, 265 female) who had relatively normal teeth arrangement, aged 16 to 70. The relationship of ala-lacrimal duct line to the distal angie of maxilly cuspid of the subjects were classified as follows; Type A : Ala-lacrimal duct line was lotated more medially than the distal angle of maxillary cuspid. Type B : Ala-lacrimal duct line coincided with the distal angle of maxillary cuspid. Type C: Ala-lacrimal duct line was located more distally than the distal angle of maxillary cuspid. The occlusal relationship of the maxillary first molar to the mandibular first molar of the subjects were classified as follows; Group I : Group of neutrocclusion relationship. Group II : Group of distocclusion relationship. Group III : Group of mesiocclusion relationship. The obtained results were as follows; 1) The positional relationship of maxillary cuspid to ala-lacrimal duct line were as follows; (Male) Type A: $68.5%{\pm}1.58m%$, Type B: $22.5%{\pm}2.30m%$, Type C: $9.1%{\pm}\1.58m%$ (Female) Type A : $64.5%{\pm}2.94m%$, Type B: $26.5%{\pm}2.71m%$, TypeC: $8.9%{\pm}1.73m%$ 2) Ala-lacrimal duct line located more distally in group II and group III than group I at the point of the positional relationship of upper and lower first molar. 3) Average distance and standard deviation in type A were as follows; (Male) Right: $2.17mm.{\pm}1.01mm.$ Left: $2.27mm.{\pm}1.02mm.$ (Female) Right: $2.06mm.{\pm}0.70mm.$ Left: $2.24mm.{\pm}0.80mm.$ 4) Average distance and standard deviation in type C were as follows; (Male), Right: $1.47mm.{\pm}0.85mm.$ Left: $1.52mm.{\pm}0.97mm.$ (Female) Right: $1.04mm.{\pm}0.44mm.$ Left: $1.26mm.{\pm}0.89mm.$ The results of 3) and 4) had no significant difference between the male and female.

  • PDF

Descriptions of Four New Species of Actinolaimoidea (Dorylaimida:Nematoda) from Korea (한국산 Actinolaimoidea상과의 (Dorylaimida:Nematoda) 4신종 기재)

  • ;Zakaullah Khan
    • The Korean Journal of Soil Zoology
    • /
    • v.5 no.2
    • /
    • pp.85-96
    • /
    • 2000
  • Four new species of predatory nematodes belonging to the Actinolaimoidea, Dorylaimida are described. Neoactinolaimus gosungensis n. sp. is 2.2-2.4 mm long, b = 4.3-4.9; c = 10.7-11.2; species 60-62 ${\mu}{\textrm}{m}$ long and is distinguishable by low lip region, asymmetrical odontostyle and its wider lumen. Egtitus arcuatus n. sp. is 1.5-1.8 mm long, b = 3.6-4.2; c = 14-15 and is characterized by having dorsally arcuate odontostyle and presence of cardiac glands at base of oesophagus. Paractinolaimus tuberculantus n. sp. is 1.9-2.5 mm long, b = 3.3-4.0, c = 7.2-8.8, spicules 66-69 ${\mu}{\textrm}{m}$ long and is unique in having coiled body posture and a tubercle at the base of oesophagus. Carcharolaimus koriensis n. sp. is 1.7-1.9 mm long, b = 3.6-4.5, c = 65-76 and is characterized by having very thick body cuticle and larger odontostyle aperture.

  • PDF

Temperature Changes in Dentin upon Pulsed Nd:YAG Lasing Distance (Pulsed Nd:YAG 레이저 조사거리에 따른 상아질의 온도변화)

  • Jae-Hyung Kim;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.327-334
    • /
    • 1995
  • In order to observe the influence of pulsed Nd:YAG laser at its out-of-contact with dentin on tooth temperature, we have applied pulsed Nd:YAG laser to 2mm thick dentin sample at a point of contact and from a distance of 1mm, 2mm, 3mm and 4mm with an energy of 0.3W, 0.5W, 0.8W, 1.5W and 2.0W. They were exposed to periods of 3 seconds, 6 seconds, 9 seconds and 15 seconds respectively and measured temperature changes. The results as follows : 1. When the time ad intensity of power were constant, the temperature changes on dentin of tooth depended on the distance. The temperature increased when the laser intensity increased bu two other conditions were contact. 2. At the point of contact, the temperature has risen over $5^{\circ}C$ regrdless of intensity of the power or the time. However, there was $5^{\circ}C$ fluctuation with 0.3 W for 3 seconds treatment. 3. The temperature change was less than $5^{\circ}C$ thermal change at the distance of 1mm and 2mm respectively when lased for 3 seconds, 6 seconds, 12 seconds and 15 seconds with 0.3 W. Similar results were observed at 3 and 6 seconds treatment with 0.5 W and at 3 seconds treatment with 0.8 and 1.0W respectively. 4. It showed less than 5(C thermal change when lased for 3 seconds, 6 seconds, 9 seconds, 12 seconds and 15 seconds with 0.3W at the distance of 3mm and 4mm. The same results were seen in 3 seconds, 6 seconds and 9 seconds treatment with 0.5W and in 3 seconds with 0.8W and 1.0W respectively. As we have seen the above, the results has indicated that pulsed Nd:YAG lasing at its off contact on dentin of 2mm thickness will not cause irreversible changes if lasing intensity, lasing distance and lasing time are appropriate.

  • PDF