• 제목/요약/키워드: MM system

검색결과 6,396건 처리시간 0.032초

로켓 노즐의 두께 변화에 대한 열응력 구조해석 (A Study on Nozzle Structure Analysis about thermal stress effect Associated with Nozzle Thickness in Rocket)

  • 소정수;도규성;장윤제;송승호;한정수;문희장
    • 항공우주시스템공학회지
    • /
    • 제2권2호
    • /
    • pp.28-34
    • /
    • 2008
  • This paper describes the performance characteristics of flow and structure in the post-chamber and nozzle. Using the computational fluid dynamics (CFD) technique, the stress and compressible flow fields in the downstream of the post chamber and nozzle were numerically calculated. Besides, the stress characteristics at the wall of post-chamber and nozzle were investigated under different thickness (2mm, 5mm and 10mm) of the nozzle wall. The stress pattern demonstrates that the strength of nozzle wall having 10mm is safer than that of 5mm or 2mm according to von Mises stress irrespective to the pressure field

  • PDF

Energy-efficient mmWave cell-free massive MIMO downlink transmission with low-resolution DACs and phase shifters

  • Seung-Eun Hong;Jee-Hyeon Na
    • ETRI Journal
    • /
    • 제44권6호
    • /
    • pp.885-902
    • /
    • 2022
  • The mmWave cell-free massive MIMO (CFmMIMO), combining the advantages of wide bandwidth in the mmWave frequency band and the high- and uniform-spectral efficiency of CFmMIMO, has recently emerged as one of the enabling technologies for 6G. In this paper, we propose a novel framework for energy-efficient mmWave CFmMIMO systems that uses low-resolution digital-analog converters (DACs) and phase shifters (PSs) to introduce lowcomplexity hybrid precoding. Additionally, we propose a heuristic pilot allocation scheme that makes the best effort to slash some interference from copilot users. The simulation results show that the proposed hybrid precoding and pilot allocation scheme outperforms the existing schemes. Furthermore, we reveal the relationship between the energy and spectral efficiencies for the proposed mmWave CFmMIMO system by modeling the whole network power consumption and observe that the introduction of low-resolution DACs and PSs is effective in increasing the energy efficiency by compromising the spectral efficiency and the network power consumption.

사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치를 이용한 폐종양 방사선수술의 유용성 평가 (Evaluation on the Usefulness of Lung Tumor Stereotactic Radiosurgery Applying the CyberKnife $Synchrony^{TM}$ Respiratory Tracking System)

  • 김가중;배석환;최준구;채홍인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.379-386
    • /
    • 2010
  • 본 연구는 사이버나이프 Synchrony 호흡추적 장치를 이용하여 방사선 수술을 시행한 폐종양 환자 48명을 대상으로 전 치료기간 중 종양의 움직임과 방사선수술의 정확성을 평가하였다. 폐종양의 움직임은 종양이나 종양주변에 삽입된 금침의 좌표를 사이버나이프 영상유도 장치로 측정하였으며, 방사선수술의 정확성은 움직임 추적 컴퓨터(MTS)로 계산된 상관관계 오차로 평가하였다. 폐종양의 움직임은 두미방향으로 평균 $2.63{\pm}1.87\;mm$며, 좌우방향 $1.13{\pm}0.71\;mm$, 전후방향 $1.74{\pm}1.16\;mm$의 움직임을 보였으며, 회전 움직임 정도는 X축 $1.66{\pm}1.66^{\circ}$, Y축 $1.20{\pm}0.97^{\circ}$, Z축 $1.18{\pm}0.73^{\circ}$로 측정되었다. 직선 움직임의 벡터 값은 평균 $3.78{\pm}2.00\;mm$값을 나타냈다. 연구 결과에서 두미방향(p<0.001)과 전후방향(p<0.029), 3차원 벡터 값(p<0.002)들은 종양의 위치가 상부보다 하부의 움직임이 크게 나타나 통계적 유의성을 보였다. 사이버나이프 Synchrony 호흡추적 장치를 이용한 폐종양의 방사선 수술시 상관관계 오차는 전체 평균 $0.95{\pm}0.62\;mm$로 매우 정확한 조사로 종양의 움직임을 보상하여 방사선 수술이 이루어졌으며 그 유용성을 확인할 수 있었다.

The Development of a Cuff for the Accuracy Enhancement of the Sphygmomanometer

  • Kim, Won-Ki;Shin, Ki-Young;Mun, Joung-Hwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.30-35
    • /
    • 2006
  • The purpose of this study is to develop a new cuff to improve the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff, which we refer to as the double bladder system. The system that we developed for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure. An oscillometric signal database based on the developed system was evaluated according to the ANSI/AAMI/SP10-1992 standard. The correlation coefficients between the cuff of the double bladder and the normal cuff were 0.98 for systolic pressure and 0.94 for diastolic pressure. The mean differences and the standard deviations between the average blood pressure obtained from a mercury manometer and that obtained from an automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diastolic pressure. We conclude that the proposed double bladder-based cuff system improves the accuracy of oscillometric blood pressure measurement. The developed system reduces the range of error by about $44{\sim}62%$ for systolic pressure and about $6{\sim}21%$ for diastolic pressure compared to the most recently developed, commercially available sphygmomanometers.

전자 혈압계의 정확도 향상을 위한 가압대 개발 (The Development of a Cuff for the Accuracy Enhancement of Sphygmomanometer)

  • 김원기;신기영;문정환
    • 한국정밀공학회지
    • /
    • 제22권5호
    • /
    • pp.181-188
    • /
    • 2005
  • The purpose of this study is to develop the new cuff improving the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff which is called the double bladder system. The developed system for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure An oscillometric signal database based on the developed system were evaluated following the standard ANSI/AAMI/SP10-1992. The correlation coefficients between cuff of double bladder and normal cuff were 0.98 for systolic and 0.94 for diastolic. Mean differences and the standard deviations between average blood pressure of mercury sphygmomanometer and automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diatolic, respectively. We conclude that the proposed double bladder based cuff system improves the accuracy of the oscillometric blood pressure measurement. The developed system reduces the error range about $44\~62\%$ for systolic and about $6\~21\%$ for diastolic compared to the recently developed commercially available sphygmomanometers.

Design of a Light and Small Dual-band Airborne Despun Optical System

  • Luqing Zhang;Ning Zhang;Xiping Xu;Kailin Zhang;Yue Zhang;Jiachong Li
    • Current Optics and Photonics
    • /
    • 제8권1호
    • /
    • pp.97-104
    • /
    • 2024
  • In aerial cameras, image quality is easily affected by weather, temperature, and the attitude of the aircraft. Aiming at this phenomenon, based on the theory of two-step zoom optical systems, a dual-band optical-despun two-step zoom optical system is designed. The system has a small field of view of 2.00° × 1.60°, and a large field of view of 4.00° × 3.20°. In the zoom process, the wavelength range is 0.45-0.70 ㎛ and 0.75-1.10 ㎛, and the size of the optical system is 168 mm (L) × 90 mm (W) × 60 mm (H). The overall lens weight is only 170.8 g, which has advantages for miniaturization and light weight. At the Nyquist frequency of 104 lp/mm, the modulation transfer function of the visible-light optical system is more than 0.44, and that of the near-infrared optical system is more than 0.30, both of which have good imaging quality and tolerance characteristics in the range of -45 to 60 ℃.

경사지에 있어서의 상수의 근계에 관한 연구 (Studies on the Root System of Mulberry Tree at Slope. Land)

  • 김문협;임수호
    • 한국잠사곤충학회지
    • /
    • 제8권
    • /
    • pp.1-9
    • /
    • 1968
  • 폭 170cm의 간이계단식 경사지에 식재된 상수의 근계를 조사한 결과는 다음과 같다. 1. 2본소식한 경우의 1소당 총근중은 2.4-2.8kg, 직경 1mm이하의 세근을 제외한 총근장은 177-255m이며 그 중에서 총근중은 직경 10mm이상의 것이 가장 많고 1-5mm의 것이 그 다음이며 1mm이하의 것과 5-10mm의 것은 가장 적다. 총근장은 이와 반대로 1-5mm의 것이 가장 길고 10mm이상의 것은 극히 짧다. 2. 수직위치에 따르는 분포는 그 중량이나 길이가 다 같이 지표에서 20cm까지의 토층에 가장 많고 20-40cm의 토층이 그 다음이며 이 부위에 전체의 90% 이상이 분포해 있다. 3. 좌우위치에 따라서 보면 상수를 중심으로 하여 좌우 각각 30cm 이내의 부위에 대부분의 뿌리가 분포해 있다. 4. 계단의 전후위치별로 보면 계단전단에서 35-70cm의 부위와 70-80cm의 부위에 가장 많이 분포해 있고 이보다 멀어지는 데 파라서 적어지며 계단의 후면보다는 전면이 뿌리의 분포가 약간 많다. 5. 각 품종간에 있어서의 근계의 분포상태는 지적할 만한 차가 없는 것 같다.

  • PDF

축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발 (A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing)

  • 안치범;문기철;정기석;남경원;이정주;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

엔드밀에 의한 고속가공시 표면형상 해석 (Topography Analysis in High Speed Working by Flat Endmill)

  • 배효준;이상재;서영백;박흥식
    • 한국기계가공학회지
    • /
    • 제1권1호
    • /
    • pp.79-88
    • /
    • 2002
  • High speed machining system have been used in industrial because it is effective to a material manufacturing with various shape. Recently the end-milling processing is needed the high-precise technique with good surface roughness and rapid time in aircraft, automobile part and molding industry. Therefore this study proposed to decide best manufacturing cutting condition for surface roughness and rapid manufacturing tune by using computer Image processing system and 3D modelling. Until the 16,000 rpm, the surface roughness is decreased rapidly, but it is not over that. The 22,000 rpm is the spindle speed with the optimum surface in the high speed end-milling. In the case of the feed rate with 2,000 mm/mm and 8,000 mm/mm, the surface roughness is better than 4,000 mm/min and 6,000 mm/min. By using the 3D modelling, it is effectively represented shape characteristics of working surface m high speed end-milling.

  • PDF

Comparison of the Characteristics of Precipitable Water Vapor Measured by Global Positioning System and Microwave Radiometer

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Won, Ji-Hye;Cho, Jung-Ho;Roh, Kyoung-Min
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2012
  • In this study, global positioning system (GPS)-derived precipitable water vapor (PWV) and microwave radiometer (MWR)-measured integrated water vapor (IWV) were compared and their characteristics were analyzed. Comparing those two quantities for two years from August 2009, we found that GPS PWV estimates were larger than MWR IWV. The average difference over the entire test period was 1.1 mm and the standard deviation was 1.2 mm. When the discrepancies between GPS PWV and MWR IWV were analyzed depending on season, the average difference was 0.7 mm and 1.9 mm in the winter and summer months, respectively. Thus, the average difference was about 2.5 times larger in summer than that in winter. However, MWR IWV measurements in the winter months were over-estimated than those in the summer months as the water vapor content got larger. The results of the diurnal analysis showed that MWR IWV was underestimated in the daytime, showing a difference of 0.8 mm. In the early morning hours, MWR IWV has a tendency to be over-estimated, with a difference of 1.3 mm with respect to GPS PWV.